Measurements of intermediate-frequency electric and magnetic fields in households

被引:32
|
作者
Aerts, Sam [1 ]
Calderon, Carolina [2 ]
Valic, Blaz [3 ]
Maslanyj, Myron [2 ]
Addison, Darren [2 ]
Mee, Terry [2 ]
Goiceanu, Cristian [2 ]
Verloock, Leen [1 ]
Van den Bossche, Matthias [1 ]
Gajsek, Peter [3 ]
Vermeulen, Roel [4 ]
Roosli, Martin [5 ,6 ]
Cardis, Elisabeth [7 ,8 ]
Martens, Luc [1 ]
Joseph, Wout [1 ]
机构
[1] Ghent Univ iMinds, Dept Informat Technol, iGent, Technol Pk Zwijnaarde 15, B-9052 Ghent, Belgium
[2] Publ Hlth England, Ctr Radiat Chem & Environm Hazards, Didcot OX11 0RQ, Oxon, England
[3] Inst Nonionizing Radiat INIS, Pohorskega Bataljona 215, Ljubljana 1000, Slovenia
[4] Univ Utrecht, Inst Risk Assessment Sci, Dept Environm Epidemiol, Yalelaan 2, NL-3508 Utrecht, Netherlands
[5] Swiss Trop & Publ Hlth Inst Swiss TPH, Socinstr 57,POB, CH-4002 Basel, Switzerland
[6] Univ Basel, Peterspl 1, CH-4003 Basel, Switzerland
[7] Barcelona Inst Global Hlth ISGlobal, Doctor Aiguader 88, Barcelona 08003, Spain
[8] Municipal Inst Med Res IMIM Hosp Mar, Doctor Aiguader 88, Barcelona 08003, Spain
关键词
Electric and magnetic fields; Human exposure; Intermediate frequencies; Household appliances; Epidemiology; IN-SITU EXPOSURE; ELECTROMAGNETIC-FIELDS; APPLIANCES; CHILDREN; SYSTEMS;
D O I
10.1016/j.envres.2017.01.001
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Historically, assessment of human exposure to electric and magnetic fields has focused on the extremely-low frequency (ELF) and radiofrequency (RF) ranges. However, research on the typically emitted fields in the intermediate-frequency (IF) range (300 Hz to 1 MHz) as well as potential effects of IF fields on the human body remains limited, although the range of household appliances with electrical components working in the IF range has grown significantly (e.g., induction cookers and compact fluorescent lighting). In this study, an extensive measurement survey was performed on the levels of electric and magnetic fields in the IF range typically present in residences as well as emitted by a wide range of household appliances under real-life circumstances. Using spot measurements, residential IF field levels were found to be generally low, while the use of certain appliances at close distance (20 cm) may result in a relatively high exposure. Overall, appliance emissions contained either harmonic signals, with fundamental frequencies between 6 kHz and 300 kHz, which were sometimes accompanied by regions in the IF spectrum of rather noisy, elevated field strengths, or much more capricious spectra, dominated by 50 Hz harmonics emanating far in the IF domain. The maximum peak field strengths recorded at 20 cm were 41.5 V/m and 2.7 A/m, both from induction cookers. Finally, none of the appliance emissions in the IF range exceeded the exposure summation rules recommended by the International Commission on Non-Ionizing Radiation Protection guidelines and the International Electrotechnical Commission (IEC 62233) standard at 20 cm and beyond (maximum exposure quotients EQ(E) 1.0 and (E)Q(H) 0.13).
引用
收藏
页码:160 / 170
页数:11
相关论文
共 50 条
  • [1] ANOMALOUS RESISTIVITY DUE TO INTERMEDIATE-FREQUENCY FIELDS
    CONRAD, JR
    GORE, R
    LASHINSK.H
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1974, 19 (06): : 739 - 739
  • [2] Exposure to extremely low and intermediate-frequency magnetic and electric fields among children from the INMA-Gipuzkoa cohort
    Gallastegi, Mara
    Jimenez-Zabala, Ana
    Santa-Marina, Loreto
    Aurrekoetxea, Juan J.
    Ayerdi, Mikel
    Ibarluzea, Jesus
    Kromhout, Hans
    Gonzalez, Julian
    Huss, Anke
    ENVIRONMENTAL RESEARCH, 2017, 157 : 190 - 197
  • [3] INTERMEDIATE-FREQUENCY FLUTE MODES IN A MAGNETIC QUADRUPOLE
    WILLETT, JE
    WU, HS
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1987, 20 (09) : 1215 - 1217
  • [4] EFFECT OF INTERMEDIATE-FREQUENCY MAGNETIC FIELD ON SEED GROWTH RATE
    Kayano, Isao
    Mochizuki, Seiichi
    JOURNAL OF PHYSIOLOGICAL SCIENCES, 2009, 59 : 161 - 161
  • [5] NEW INTERMEDIATE-FREQUENCY MODULATOR
    BELTZER, B
    CLUNIAT, C
    REVUE TECHNIQUE THOMSON-CSF, 1977, 9 (03): : 603 - 643
  • [6] Early Exposure to Intermediate-Frequency Magnetic Fields Alters Brain Biomarkers without Histopathological Changes in Adult Mice
    Win-Shwe, Tin-Tin
    Ohtani, Shin
    Ushiyama, Akira
    Kunugita, Naoki
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2015, 12 (04): : 4406 - 4421
  • [7] SPOT MEASUREMENTS OF INTERMEDIATE FREQUENCY ELECTRIC FIELDS IN THE VICINITY OF COMPACT FLUORESCENT LAMPS
    Bakos, Jozsef
    Nagy, Noemi
    Juhasz, Peter
    Thuroczy, Gyoergy
    RADIATION PROTECTION DOSIMETRY, 2010, 142 (2-4) : 354 - 357
  • [8] Arc Modes of Intermediate-Frequency Vacuum Arc with Axial Magnetic Field
    Wang Jing
    Wu Jianwen
    Zhu Liying
    Shi Yanhua
    ISDEIV 2010: XXIVTH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM, 2010, : 311 - 314
  • [9] Behavior of Intermediate-Frequency Vacuum Arc under Transverse Magnetic Field
    Zhu Liying
    Wu Jianwen
    Wang Jing
    Shi Yanhua
    ISDEIV 2010: XXIVTH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM, 2010, : 288 - 291
  • [10] Properties of Intermediate-Frequency Vacuum Arc Under Axial Magnetic Field
    Wang Jing
    Wu Jianwen
    Zhu Liying
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2009, 37 (08) : 1477 - 1483