A Comparison of Mobile and Fixed-Bearing Unicompartmental Knee Arthroplasty at a Minimum 10-Year Follow-up

被引:53
|
作者
Neufeld, Michael E. [1 ]
Albers, Anthony [2 ]
Greidanus, Nelson, V [1 ]
Garbuz, Donald S. [1 ]
Masri, Bassam A. [1 ]
机构
[1] Univ British Columbia, Dept Orthopaed, Reconstruct Orthopaed, Vancouver, BC, Canada
[2] McGill Univ, St Marys Hosp, Dept Orthopaed, Montreal, PQ, Canada
来源
JOURNAL OF ARTHROPLASTY | 2018年 / 33卷 / 06期
关键词
unicompartmental knee arthroplasty; mobile-bearing; fixed-bearing; implant survival; functional outcomes; revision; INDEPENDENT CENTER; OUTCOMES; REPLACEMENT; REVISION; IMPLANT; FAILURE; ARTHRITIS; MODES; RATES; SCORE;
D O I
10.1016/j.arth.2018.01.001
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The long-term survivorship and functional outcomes of the mobile-bearing (MB) compared to the fixed-bearing (FB) unicompartmental knee arthroplasty (UKA) implant design remain a topic of debate. The aim of the current study was to compare the survivorship and functional outcomes of MB and FB UKA at a minimum 10-year follow-up. Methods: We retrospectively reviewed 106 consecutive medial UKAs (89 patients) from our institution with a minimum 10-year follow-up. The 38 MB and 68 FB knees had follow-up of 14.2 years (12.9-15.5) and 11.5 years (10.2-15.1), respectively. Validated patient-reported outcomes and radiographs were evaluated as were etiology, timing, and complexity of revision. Kaplan-Meier 10-year survival was calculated with revision to total knee arthroplasty as the end point. Results: The 10-year survival was 82.9% (95% confidence interval [CI] 65.8-91.9) for MB and 90.9% (95% CI 79.4-96.2) for FB UKA (P = .102), and 88.0% (95% CI 79.3-93.2) for the entire cohort. Patient outcomes were similar between groups, as were timing and etiologies for revision to total knee arthroplasty. One-third of revisions required either stems or tibial augments, and of these, all were of MB design. Conclusion: Survival and functional outcomes were similar between MB and FB designs. One-third of revisions required either stems or augments, all were of MB design. (C) 2018 Elsevier Inc. All rights reserved.
引用
收藏
页码:1713 / 1718
页数:6
相关论文
共 50 条
  • [41] Lateral unicompartmental knee arthroplasty: Mobile and fixed bearing
    Walker T.
    Merle C.
    Gotterbarm T.
    Aldinger P.R.
    Arthroskopie, 2017, 30 (4) : 302 - 311
  • [42] Fixed-bearing vs mobile-bearing prostheses for total knee arthroplasty after approximately 10years of follow-up: a meta-analysis
    Hao, Dongsheng
    Wang, Junjie
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01) : 437
  • [43] Results of unicompartmental knee arthroplasty at a minimum of ten years of follow-up
    Berger, RA
    Meneghini, RM
    Jacobs, JJ
    Sheinkop, MB
    Della Valle, CJ
    Rosenberg, AG
    Galante, JO
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (05): : 999 - 1006
  • [44] Comparison of Fixed-Bearing and Mobile Bearing Total Knee Arthroplasty in and around Kanchipuram Population
    Reddy, Manoj
    Yadav, Omprakash
    Dhanasekar, Munuswamy Gurupadham Rajesh
    JOURNAL OF PHARMACEUTICAL NEGATIVE RESULTS, 2022, 13 : 272 - 280
  • [45] Denham total knee arthroplasty - A 10-year follow-up study
    Mangaleshkar, SR
    Bajaj, SK
    Thomas, AP
    JOURNAL OF ARTHROPLASTY, 2002, 17 (05): : 550 - 555
  • [46] Alignment in Medial Fixed-Bearing Unicompartmental Knee Arthroplasty: The Limb Has a Leg Up on the Component
    Slaven, Sean E.
    Cody, John P.
    Sershon, Robert A.
    Ho, Henry
    Hopper, Robert H., Jr.
    Fricka, Kevin B.
    JOURNAL OF ARTHROPLASTY, 2021, 36 (12): : 3883 - 3887
  • [47] Clinical Results of Lateral Unicompartmental Knee Arthroplasty: Minimum 2-Year Follow-up
    Kim, Kyung Tae
    Lee, Song
    Kim, Jeehyoung
    Kim, Jin Woo
    Kang, Min Su
    CLINICS IN ORTHOPEDIC SURGERY, 2016, 8 (04) : 386 - 392
  • [48] Tantalum Cones for Severe Bone Defects in Revision Knee Arthroplasty: A Minimum 10-Year Follow-Up
    De Martino, Ivan
    Mancino, Fabio
    Di Matteo, Vincenzo
    Singlitico, Alessandro
    Maccauro, Giulio
    Gasparini, Giorgio
    JOURNAL OF ARTHROPLASTY, 2023, 38 (05): : 886 - 892
  • [49] No difference in joint awareness after mobile- and fixed-bearing total knee arthroplasty: 3-year follow-up of a randomized controlled trial
    Schotanus M.G.M.
    Pilot P.
    Vos R.
    Kort N.P.
    European Journal of Orthopaedic Surgery & Traumatology, 2017, 27 (8) : 1151 - 1155
  • [50] Retrospective comparison of rates of aseptic loosening in fixed-bearing unicompartmental knee arthroplasty (UKA) implants
    Boucher, Henry R.
    Hawken, Jessica
    Lee, Ji Won
    Mistretta, Katherine
    Gallagher, Brian
    Passano, Brandon
    Desale, Sameer
    CURRENT ORTHOPAEDIC PRACTICE, 2022, 33 (04): : 372 - 375