Immunohistochemistry comparing endoscopic vein harvesting vs. open vein harvesting on saphenous vein endothelium

被引:15
|
作者
Nezafati, Mohammad Hassan [1 ]
Nezafati, Pouya [2 ]
Amoueian, Sakineh [3 ]
Attaranzadeh, Armin [4 ]
Rahimi, Hamid Reza [5 ]
机构
[1] Mashhad Univ Med Sci, Emam Reza Acad Hosp, Dept Cardiac Surg, Mashhad 91878, Iran
[2] Mashhad Univ Med Sci, Student Res Comm, Mashhad 91878, Iran
[3] Mashhad Univ Med Sci, Emam Reza Acad Hosp, Dept Pathol, Mashhad 91878, Iran
[4] Mashhad Univ Med Sci, Dept Mol Pathol & Cytogenet, Mashhad 91878, Iran
[5] Mashhad Univ Med Sci, Sch Med, Dept Modern Sci & Technol, Student Res Comm, Mashhad 91878, Iran
来源
关键词
EVH; OVH; vWf; E-cadherin; Caveolin; eNOSs; BYPASS GRAFT-SURGERY; PROSPECTIVE RANDOMIZED-TRIAL; WOUND COMPLICATIONS; SAPHENECTOMY; DAMAGE; CABG;
D O I
10.1186/1749-8090-9-101
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: The present study attempts to compare the immunohistochemistry (IHC) of von Willebrand factor (vWf), endothelial cadherin, Caveolin and endothelial Nitric Oxide Synthase (eNOS) in VasoView Endoscopic Vein Harvesting (EVH) versus traditional Open Vein Harvesting (OVH) techniques for Coronary Artery Bypass Graft (CABG) Surgery performed in Javad al Aemeh Hospital of Mashhad, Iran in 2013,. Methods and materials: Forty-seven patients were scheduled for CABG (30 EVH and 17 OVH) among whom patients with relatively same gender and similar age were selected. Three separate two cm vein samples were harvested from each patient's saphenous vein. Each portion was collected from distal, middle and proximal zones of the saphenous vein. The tissues were deparaffinized, and antigen retrieval was done using EZ-retriever followed by an immunohistochemistry evaluation with vWf, e-cadherin, Caveolin and eNOS. In addition, demographic questioner as of Lipid profile, FBS, BMI, and cardiovascular risk factors were collected. Data analyses, including parametric and nonparametric tests were undertaken using the SPSS 16 software. A P value < 0.05 was regarded as statistically significant. Results: The mean age of the EVH and OVH groups were 63.76 +/- 9.51 and 63.63 +/- 8.31 years respectively with no significant difference between them (p = 0.989). In addition, there was no great difference between the EVH and OVH groups in lipid profile, DM, HTN, smoking history, CVA, and valvular dysfunction (P > 0.05). Qualitative report of vWf, e-cadherin, Caveolin and eNOS reveals no significant difference between the EVH and OVH (P > 0.05). Conclusion: This study indicates that VasoView EVH technique causes no endothelial damage in comparison with OVH. This study could be a molecular confirmation for the innocuous of EVH technique.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Endoscopic versus open great saphenous vein harvesting for femoral to popliteal artery bypass
    Mirza, Aleem K.
    Stauffer, Kendall
    Fleming, Mark D.
    De Martino, Randall
    Oderich, Gustavo
    Kalra, Manju
    Gloviczki, Peter
    Bower, Thomas
    JOURNAL OF VASCULAR SURGERY, 2018, 67 (04) : 1199 - 1206
  • [32] Leg Wound Complications: A Comparison Between Endoscopic and Open Saphenous Vein Harvesting Techniques
    Mubarak, Yasser
    Abdeljawad, Ahmed
    HEART SURGERY FORUM, 2021, 24 (04): : E604 - E610
  • [33] Endoscopic versus open vein-graft harvesting
    Le Bras A.
    Nature Reviews Cardiology, 2019, 16 (1) : 3 - 3
  • [34] Endoscopic versus Open Vein-Graft Harvesting
    Dacey, Lawrence J.
    Braxton, John H.
    Likosky, Donald S.
    NEW ENGLAND JOURNAL OF MEDICINE, 2009, 361 (19): : 1908 - 1908
  • [35] Demise of Open Vein Harvesting
    Aranki, Sary F.
    Shopnick, Barry
    CIRCULATION, 2011, 123 (02) : 127 - 128
  • [36] Study Comparing Vein Integrity and Clinical Outcomes in Open Vein Harvesting and 2 Types of Endoscopic Vein Harvesting for Coronary Artery Bypass Grafting The VICO Randomized Clinical Trial (Vein Integrity and Clinical Outcomes)
    Krishnamoorthy, Bhuvaneswari
    Critchley, William R.
    Thompson, Alexander J.
    Payne, Katherine
    Morris, Julie
    Venkateswaran, Rajamiyer V.
    Caress, Ann L.
    Fildes, James E.
    Yonan, Nizar
    CIRCULATION, 2017, 136 (18) : 1688 - +
  • [37] Endoscopic versus traditional saphenous vein harvesting: A prospective, randomized trial
    Allen, KB
    Griffith, GL
    Heimansohn, DA
    Robison, RJ
    Matheny, RG
    Schier, JJ
    Fitzgerald, EB
    Shaar, CJ
    ANNALS OF THORACIC SURGERY, 1998, 66 (01): : 26 - 31
  • [38] Is endoscopic harvesting bad for saphenous vein graft patency in coronary surgery?
    Kiani, Soroosh
    Poston, Robert
    CURRENT OPINION IN CARDIOLOGY, 2011, 26 (06) : 518 - 522
  • [39] Minimally invasive saphenous vein harvesting: is there an improvement of the results with the endoscopic approach?
    Isgro, F
    Weisse, U
    Voss, B
    Kiessling, AH
    Saggau, W
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1999, 16 : S58 - S60
  • [40] New technique for lesser saphenous vein harvesting
    Lamphere, JA
    Daily, PO
    Moreno, RJ
    Marcus, S
    Dembitsky, WP
    Adamson, RM
    Burr, M
    ONeill, P
    ANNALS OF THORACIC SURGERY, 1995, 60 (06): : 1829 - 1830