An Effect of Climatic States on the Current Loading of Overhead Power Lines

被引:0
|
作者
Svec, Jan [1 ]
机构
[1] FEL CVUT Praze, Katedra Elektroenerget, Prague 16627, Czech Republic
关键词
Ampacity; Temperature; Overhead Powerline; Overload;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper describes and applies computational models, the usage of which can decide about the transmission System lines operation. Overhead lines thermal models include the thermal power balance and work with the conductor current and temperature in a steady, unsteady and transient state. In the cooperation with the steady state calculation, in the example of a system, extraordinary states calculations are performed and results are concluded with respect to standard requirements how to solve these states.
引用
收藏
页码:67 / 73
页数:7
相关论文
共 50 条
  • [1] Effect of are current on properties of composite insulators for overhead lines
    Mazurek, B
    Maczka, T
    Gmitrzak, A
    PROCEEDINGS OF THE 6TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1 & 2, 2000, : 802 - 805
  • [2] Power Losses on Overhead Lines under Various Loading Regimes and Weather Conditions
    Baran, Ileana
    Costea, Marian
    Leonida, Tudor
    2017 5TH INTERNATIONAL SYMPOSIUM ON ELECTRICAL AND ELECTRONICS ENGINEERING (ISEEE), 2017,
  • [3] GROUND RETURN EFFECTS IN CURRENT MEASUREMENT OF OVERHEAD POWER-LINES
    NAKAGAWA, M
    IWAMOTO, K
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1979, 98 (04): : 1143 - 1143
  • [4] Frequency Effect on Electromagnetic States Emitted from High Voltage Overhead Power Lines and Busbar Substation
    Bendakir, Abdelhakim
    Metatla, Samir
    Mayache, Hichem
    Dib, Djalel
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2024, 52 (10) : 1946 - 1959
  • [5] Effect of Shielding Lines on Power Frequency Electric Field under Overhead Lines
    Jiang, Yuze
    Liang, Zhenguang
    Ma, Weijie
    Wang, Hongchuan
    THERMAL, POWER AND ELECTRICAL ENGINEERING, PTS 1 AND 2, 2013, 732-733 : 999 - +
  • [6] The safety of overhead power lines
    Ashley, JR
    IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1997, 16 (01): : 25 - &
  • [7] Assessment of climatic factors influence on the time to reach maximum wire temperature of overhead power lines
    Bigun, Aleksandr A. Y.
    Girshin, Stanilav S.
    Goryunov, Vladimir N.
    Shepelev, Aleksandr O.
    Prus, Svetlana Yu
    Tkachenko, Vsevolod A.
    PRZEGLAD ELEKTROTECHNICZNY, 2020, 96 (08): : 39 - 42
  • [8] Neural expert system for loading of overhead lines
    Negnevitsky, M
    Le, TL
    PROGRESS IN CONNECTIONIST-BASED INFORMATION SYSTEMS, VOLS 1 AND 2, 1998, : 797 - 800
  • [9] DYNAMIC CURRENT RATING OF OVERHEAD LINES
    WEEDY, BM
    ELECTRIC POWER SYSTEMS RESEARCH, 1989, 16 (01) : 11 - 15
  • [10] Organization of the melting of ice by an alternating current on the wires of overhead electric power lines
    R. G. Shakirov
    F. R. Ismagilov
    N. L. Babikova
    Power Technology and Engineering, 2012, 46 (2) : 163 - 167