Spectrum of the ion-trap laser

被引:51
|
作者
Meyer, GM [1 ]
Loffler, M [1 ]
Walther, H [1 ]
机构
[1] UNIV MUNICH, SEKT PHYS, D-8000 MUNICH, GERMANY
来源
PHYSICAL REVIEW A | 1997年 / 56卷 / 02期
关键词
D O I
10.1103/PhysRevA.56.R1099
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The spectral properties of the ion-trap laser [Europhys. Lett. 37, 317 (1997)] are investigated for a realistic multilevel scheme containing a h-type subsystem. In the laser region, the linewidth of the output spectrum is up to ten times smaller than the cavity damping rate and roughly proportional to the inverse of the mean photon number. Significant modifications and photon antibunching occur for thresholdless lasing. The fluorescence spectrum displays the signature of the coherently scattered resonator field.
引用
收藏
页码:R1099 / R1102
页数:4
相关论文
共 50 条
  • [31] Vibrational decoherence in ion-trap quantum computers
    Garg, A
    PHOTONIC QUANTUM COMPUTING II, 1998, 3385 : 38 - 49
  • [32] Building and characterizing a stylus ion-trap system
    崔太豪
    魏雅琪
    李冀
    袁泉
    戴双晴
    李沛东
    周飞
    张建奇
    郑驻军
    陈亮
    冯芒
    Chinese Physics B, 2024, 33 (04) : 271 - 276
  • [33] Microcoded architectures for ion-trap quantum computers
    Kreger-Stickles, Lucas
    Oskin, Mark
    ISCA 2008 PROCEEDINGS: 35TH INTERNATIONAL SYMPOSIUM ON COMPUTER ARCHITECTURE, 2008, : 165 - 176
  • [34] THE SUPER ELECTRON-BEAM ION-TRAP
    MARRS, RE
    BEIERSDORFER, P
    ELLIOTT, SR
    KNAPP, DA
    STOEHLKER, T
    PHYSICA SCRIPTA, 1995, T59 : 183 - 188
  • [35] Compact toroidal ion-trap design and optimization
    Madsen, M. J.
    Gorman, C. H.
    PHYSICAL REVIEW A, 2010, 82 (04):
  • [36] A realizable distributed ion-trap quantum computer
    Thaker, Darshan D.
    Metodi, Tzvetan S.
    Chong, Frederic T.
    HIGH PERFORMANCE COMPUTING - HIPC 2006, PROCEEDINGS, 2006, 4297 : 111 - +
  • [37] Generation of cluster states in ion-trap systems
    Zheng, Shi-Biao
    PHYSICAL REVIEW A, 2006, 73 (06):
  • [38] Topological features in ion-trap holonomic computation
    Pachos, Jiannis
    Physical Review A - Atomic, Molecular, and Optical Physics, 2002, 66 (04): : 423181 - 423186
  • [39] Analysis of biomolecules using electrospray ionization ion-trap mass spectrometry and laser photodissociation
    Stephenson, JL
    Booth, MM
    Boue, SM
    Eyler, JR
    Yost, RA
    BIOCHEMICAL AND BIOTECHNOLOGICAL APPLICATIONS OF ELECTROSPRAY IONIZATION MASS SPECTROMETRY, 1996, 619 : 512 - 564
  • [40] Ion-trap MS aims to catch the wave
    不详
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2010, 29 (04) : V - V