The vacuum system of the LHCb vertex detector

被引:1
|
作者
van den Brand, JFJ
Doets, M
Kraan, M
Klous, S
Kaan, AP
机构
[1] NIKHEF H, Amsterdam, Netherlands
[2] Vrije Univ Amsterdam, NL-1081 HV Amsterdam, Netherlands
关键词
D O I
10.1016/S0042-207X(02)00206-3
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
An overview of the design of the vertex detector of the LHCb experiment in the future Large Hadron Collider at CERN will be given. The application of silicon detectors close to the beam implies the isolation of the materials with a high desorption rate from the accelerator vacuum. The aluminium containment has a complicated shape and a thickness of 250 mum in order to minimize the multiple scattering. Alignment, safety and precision problems have been solved in the design and are being tested. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:363 / 371
页数:9
相关论文
共 50 条
  • [41] Upgrade of the LHCb Vertex Locator
    Leflat, A.
    JOURNAL OF INSTRUMENTATION, 2014, 9
  • [42] A vertex trigger for the LHCb experiment
    Tuning, N
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 511 (1-2): : 157 - 160
  • [43] Performance of the LHCb Vertex Locator
    Aaij, R.
    Affolder, A.
    Akiba, K.
    Alexander, M.
    Ali, S.
    Appleby, R. B.
    Artuso, M.
    Bates, A.
    Bay, A.
    Behrendt, O.
    Benton, J.
    Van Beuzekom, M.
    Bjornstad, P. M.
    Bogdanova, G.
    Borghi, S.
    Borgia, A.
    Bowcock, T. J. V.
    Van den Brand, J.
    Brown, H.
    Buytaert, J.
    Callot, O.
    Carroll, J.
    Casse, G.
    Collins, P.
    Capua, S. De
    Doets, M.
    Donleavy, S.
    Dossett, D.
    Dumps, R.
    Eckstein, D.
    Eklund, L.
    Farinelli, C.
    Farry, S.
    Ferro-Luzzi, M.
    Frei, R.
    Garofoli, J.
    Gersabeck, M.
    Gershon, T.
    Gong, A.
    Gong, H.
    Gordon, H.
    Haefeli, G.
    Harrison, J.
    Heijne, V.
    Hennessy, K.
    Hulsbergen, W.
    Huse, T.
    Hutchcroft, D.
    Jaeger, A.
    Jalocha, P.
    JOURNAL OF INSTRUMENTATION, 2014, 9
  • [44] A γ Detector Movement System of the Spectrometer with a Vertex Detector Setup
    Golovkin, V. F.
    Golovnya, S. N.
    Gorokhov, S. A.
    Ustinov, E. A.
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2014, 57 (03) : 274 - 278
  • [45] A γ detector movement system of the spectrometer with a vertex detector setup
    V. F. Golovkin
    S. N. Golovnya
    S. A. Gorokhov
    E. A. Ustinov
    Instruments and Experimental Techniques, 2014, 57 : 274 - 278
  • [46] Status of the LHCb VErtex LOcator
    Palacios, JP
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 511 (1-2): : 38 - 42
  • [47] Performance of the LHCb Vertex Locator
    Bjornstad, P. M.
    JOURNAL OF INSTRUMENTATION, 2011, 6
  • [48] Performance evaluation of the control system for the LHCb Muon Detector
    Bocci, Valerio
    Chiodi, Giacomo
    Iacoangeli, Francesco
    Nobrega, Rafael
    Pinci, Davide
    Rinaldi, Walter
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 769 - 772
  • [49] The LHCb VERTEX LOCATOR performance and VERTEX LOCATOR upgrade
    Rodriguez Perez, P.
    JOURNAL OF INSTRUMENTATION, 2012, 7
  • [50] Characterisation of a radiation hard front-end chip for the vertex detector of the LHCb experiment at CERN
    van Bakel, N
    Baumeister, D
    van Beuzekom, M
    Bulten, HJ
    Feuerstack-Raible, M
    Jans, E
    Ketel, T
    Klous, S
    Löchner, S
    Sexauer, E
    Smale, N
    Snoek, H
    Trunk, U
    Verkooijen, H
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 509 (1-3): : 176 - 182