Exploiting coherence for real-time studies by single-bunch imaging

被引:48
|
作者
Rack, A. [1 ]
Scheel, M. [1 ]
Hardy, L. [1 ]
Curfs, C. [1 ]
Bonnin, A. [1 ]
Reichert, H. [1 ]
机构
[1] European Synchrotron Radiat Facil, F-38000 Grenoble, France
关键词
ultra-fast phenomena; picosecond; X-ray phase contrast; radioscopy; crack propagation; coalescence; fracture; X-RAY; SYNCHROTRON-RADIATION; DYNAMICS; FRACTURE;
D O I
10.1107/S1600577514005852
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
First real-time studies of ultra-fast processes by single-bunch imaging at the European Synchrotron Radiation Facility are reported. By operating the storage ring of the ESRF in single-bunch mode with its correspondingly increased electron bunch charge density per singlet, the polychromatic photon flux density at insertion-device beamlines is sufficient to capture hard X-ray images exploiting the light from a single bunch (the corresponding bunch length is 140 ps FWHM). Hard X-ray imaging with absorption contrast as well as phase contrast in combination with large propagation distances is demonstrated using spatial samplings of 11 mu m and 35 mu m pixel size. The images acquired allow one to track crack propagation in a bursting piece of glass, breaking of an electrical fuse as well as cell wall rupture in an aqueous foam. Future developments and their potential in the frame of the proposed Phase II of the ESRF Upgrade Program are discussed.
引用
收藏
页码:815 / 818
页数:4
相关论文
共 50 条
  • [41] Real-time metabolic imaging
    Golman, Klaes
    in't Zandt, Rene
    Thaning, Mikkel
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2006, 103 (30) : 11270 - 11275
  • [42] REAL-TIME MEGAVOLTAGE IMAGING
    BOVA, FJ
    FITZGERALD, LT
    MAUDERLI, WM
    ISLAM, MK
    MEDICAL PHYSICS, 1987, 14 (04) : 707 - 707
  • [43] REAL-TIME IMAGING OF THE ADRENALS
    GHOLKAR, J
    BRITISH JOURNAL OF RADIOLOGY, 1985, 58 (687): : 276 - 276
  • [44] REAL-TIME TRITIUM IMAGING
    MALINOWSKI, ME
    APPLIED PHYSICS LETTERS, 1981, 39 (06) : 509 - 511
  • [45] Measurement of the time profile of a single-bunch electron beam with wireline pickup by considering the wake-field effect
    Homma, A
    Sawamura, T
    Yamazaki, H
    Ohkuma, J
    Okuda, S
    Yamamoto, T
    Suemine, S
    Tsumori, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 371 (03): : 355 - 357
  • [46] REAL-TIME ACOUSTIC IMAGING
    MELTREGER, BI
    KHEIFETS, EI
    SOVIET PHYSICS ACOUSTICS-USSR, 1979, 25 (02): : 168 - 169
  • [47] REAL-TIME DIGITAL IMAGING
    PETERSON, DK
    BENNETT, S
    KINO, GS
    IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1982, 29 (03): : 160 - 160
  • [48] REAL-TIME IMAGING PROCESSING
    MENGERS, P
    MATERIALS EVALUATION, 1983, 41 (02) : A13 - A13
  • [49] Real-time tumour imaging
    Habeck, M
    LANCET ONCOLOGY, 2002, 3 (07): : 387 - 387
  • [50] REAL-TIME IMAGING IN CARDIOLOGY
    PRIDIE, RB
    BRITISH JOURNAL OF RADIOLOGY, 1978, 51 (608): : 642 - 643