Influence of Surrounding Structures upon the Aerodynamic and Acoustic Performance of the Outdoor Unit of a Split Air-Conditioner

被引:5
|
作者
Wu Chengjun [1 ]
Liu Jiang [1 ]
Pan Jie [2 ]
机构
[1] Xi An Jiao Tong Univ, Sch Mech Engn, Xian 710049, Peoples R China
[2] Univ Western Australia, Sch Mech & Chem Engn, Crawley, WA 6009, Australia
关键词
DC-inverter split air-conditioner; outdoor unit; surrounding structure; computational fluid dynamics(CFD); computational aerodynamic acoustics(CAA); simulation; improved design; AXIAL-FLOW FAN; BROAD-BAND NOISE; AEROACOUSTIC NOISE; LDV MEASUREMENTS; PROPELLER FAN; PREDICTION; SIMULATION; SOUND; FIELD; SET;
D O I
10.3901/CJME.2014.0515.095
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
DC-inverter split air-conditioner is widely used in Chinese homes as a result of its high-efficiency and energy-saving. Recently, the researches on its outdoor unit have focused on the influence of surrounding structures upon the aerodynamic and acoustic performance, however they are only limited to the influence of a few parameters on the performance, and practical design of the unit requires more detailed parametric analysis. Three-dimensional computational fluid dynamics(CFD) and computational aerodynamic acoustics(CAA) simulation based on FLUENT solver is used to study the influence of surrounding structures upon the aforementioned properties of the unit. The flow rate and sound pressure level are predicted for different rotating speed, and agree well with the experimental results. The parametric influence of three main surrounding structures(i.e. the heat sink, the bell-mouth type shroud and the outlet grille) upon the aerodynamic performance of the unit is analyzed thoroughly. The results demonstrate that the tip vortex plays a major role in the flow fields near the blade tip and has a great effect on the flow field of the unit. The inlet ring's size and throat's depth of the bell-mouth type shroud, and the through-flow area and configuration of upwind and downwind sections of the outlet grille are the most important factors that affect the aerodynamic performance of the unit. Furthermore, two improved schemes against the existing prototype of the unit are developed, which both can significantly increase the flow rate more than 6 %(i.e. 100 m(3) center dot h(-1)) at given rotating speeds. The inevitable increase of flow noise level when flow rate is increased and the advantage of keeping a lower rotating speed are also discussed. The presented work could be a useful guideline in designing the aerodynamic and acoustic performance of the split air-conditioner in engineering practice.
引用
收藏
页码:836 / 845
页数:10
相关论文
共 42 条
  • [1] Influence of surrounding structures upon the aerodynamic and acoustic performance of the outdoor unit of a split air-conditioner
    Chengjun Wu
    Jiang Liu
    Jie Pan
    Chinese Journal of Mechanical Engineering, 2014, 27 : 836 - 845
  • [2] Influence of Surrounding Structures upon the Aerodynamic and Acoustic Performance of the Outdoor Unit of a Split Air-Conditioner
    WU Chengjun
    LIU Jiang
    PAN Jie
    Chinese Journal of Mechanical Engineering, 2014, (04) : 836 - 845
  • [3] Influence of Surrounding Structures upon the Aerodynamic and Acoustic Performance of the Outdoor Unit of a Split Air-Conditioner
    WU Chengjun
    LIU Jiang
    PAN Jie
    Chinese Journal of Mechanical Engineering, 2014, 27 (04) : 836 - 845
  • [4] A study of the aerodynamic and acoustic performance of an indoor unit of a DC-inverter split air-conditioner
    Wu, C. J.
    Liu, D. P.
    Pan, J.
    APPLIED ACOUSTICS, 2012, 73 (04) : 415 - 422
  • [5] Prediction and measurement of axial flow fan aerodynamic and aeroacoustic performance in a split-type air-conditioner outdoor unit
    Zhao, Xifeng
    Sun, Jinju
    Zhang, Zhi
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2013, 36 (03): : 1098 - 1108
  • [6] Noise control and sound quality evaluation of outdoor unit of split air-conditioner
    Wu, Chengjun
    Lei, Xiaofei
    JOURNAL OF MEASUREMENTS IN ENGINEERING, 2016, 4 (02) : 58 - 69
  • [7] EFFECT OF THE OUTDOOR UNIT ARRANGEMENTS ON COP OF AN AIR-CONDITIONER
    Li, Hao
    Huang, Chen
    Zou, Zhijun
    Wang, Fei
    FIFTH INTERNATIONAL WORKSHOP ON ENERGY AND ENVIRONMENT OF RESIDENTIAL BUILDINGS AND THIRD INTERNATIONAL CONFERENCE ON BUILT ENVIRONMENT AND PUBLIC HEALTH, VOL I AND II, PROCEEDINGS, 2009, : 2273 - 2278
  • [8] Flow velocity around air-conditioner outdoor unit
    Xu, Chen
    Ou, Chunshan
    Gu, Xiaojiang
    Wang, Chao
    Mao, Yijun
    PHYSICS OF FLUIDS, 2025, 37 (01)
  • [9] Aerodynamic and aeroacoustic study of collateral axial flow fan system inside outdoor unit of air-conditioner
    Ouyang, Hua
    Tian, Jie
    Wu, Yadong
    Zheng, Zhiming
    Sumio, Shiochi
    Jixie Gongcheng Xuebao/Chinese Journal of Mechanical Engineering, 2007, 43 (10): : 215 - 220
  • [10] Comprehensive study of the impacts of surrounding structures on the aero-dynamic performance and flow characteristics of an outdoor unit of split-type air conditioner
    Mehryan, S. A. M.
    Kashkooli, Farshad M.
    Soltani, M.
    BUILDING SIMULATION, 2018, 11 (02) : 325 - 337