Brain MR imaging in patients with hepatic cirrhosis: Relationship between high intensity signal in basal ganglia on T-1-weighted images and elemental concentrations in brain

被引:113
|
作者
Maeda, H
Sato, M
Yoshikawa, A
Kimura, M
Sonomura, T
Terada, M
Kishi, K
机构
[1] Department of Radiology, Wakayama Medical College, Wakayama City
关键词
brain magnetic resonance imaging; basal ganglia; cirrhosis; hepatic; manganese;
D O I
10.1007/s002340050464
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
In patients with hepatic cirrhosis, the globus pallidus and putamen show high intensity on T1-weighted MRI. While the causes of this high signal have been thought to include paramagnetic substances, especially manganese, no evidence for this has been presented. Autopsy in four cases of hepatic cirrhosis permitted measurement of metal concentrations in brain and histopathological examination. In three cases the globus pallidus showed high intensity on T1-weighted images. Mean manganese concentrations in globus pallidus. putamen and frontal white matter were 3.03 +/- 0.38, 2.12 +/- 0.37, and 1.38 +/- 0.24 (mu g/g wet weight), respectively, being approximately four- to almost ten-fold the normal values. Copper concentrations in globus pallidus and putamen were also high, 50 % more than normal. Calcium, iron, zinc and magnesium concentrations were all normal. The fourth case showed no abnormal intensity in the basal ganglia and brain metal concentrations were all normal. Histopathologically, cases with showing high signal remarkable atrophy necrosis, and deciduation of nerve cells and proliferation of glial cells and microglia in globus pallidus. These findings were similar to those in chronic manganese poisoning. On T1-weighted images, copper deposition shows no abnormal intensity. It is therefore inferred that deposition of highly concentrations of manganese may caused high signal on T1-weighted images and nerve cell death in the globus pallidus.
引用
收藏
页码:546 / 550
页数:5
相关论文
共 50 条
  • [21] MR IMAGING OF BRAIN METASTASES (1)T2-WEIGHTED IMAGES AS A SCREENING SEQUENCE
    HOSTEN, N
    SCHORNER, W
    SCHUBEUS, P
    FELIX, R
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1990, 153 (03): : 321 - 326
  • [22] Relationship between contrast enhancement on fluid-attenuated inversion recovery MR sequences and signal intensity on T2-weighted MR images: Visual evaluation of brain tumors
    Kubota, T
    Yamada, K
    Kizu, O
    Hirota, T
    Ito, H
    Ishihara, K
    Nishimura, T
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (06) : 694 - 700
  • [23] Intracranial Lesions with High Signal Intensity on T1-weighted MR Images: Differential Diagnosis
    Ginat, Daniel T.
    Meyers, Steven P.
    RADIOGRAPHICS, 2012, 32 (02) : 499 - 516
  • [24] Intracranial lesions with high signal intensity on T1-weighted MR images - review of pathologies
    Zimny, Anna
    Zinska, Lidia
    Bladowska, Joanna
    Neska-Matuszewska, Malgorzata
    Sasiadek, Marek
    POLISH JOURNAL OF RADIOLOGY, 2013, 78 (04) : 36 - 46
  • [25] MR Findings of Fungus Ball: Significance of High Signal Intensity on T1-Weighted Images
    Kim, Soo Chin
    Ryoo, Inseon
    Shin, Jae Min
    Suh, Sangil
    Jung, Hye Na
    Shin, Sung Ui
    JOURNAL OF KOREAN MEDICAL SCIENCE, 2020, 35 (03)
  • [26] The Effect of Inversion Time on the Relationship Between Iron Oxide Nanoparticles Concentration and Signal Intensity in T1-Weighted MR Images
    Saharkhiz, Hodaiseh
    Gharehaghaji, Nahideh
    Nazarpoor, Mahmood
    Mesbahi, Asghar
    Pourissa, Masoud
    IRANIAN JOURNAL OF RADIOLOGY, 2014, 11 (02)
  • [27] Age-Dependent Signal Intensity Changes in the Structurally Normal Pediatric Brain on Unenhanced T1-Weighted MR Imaging
    Flood, T. F.
    Bhatt, P. R.
    Jensen, A.
    Maloney, J. A.
    Stence, N., V
    Mirsky, D. M.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2019, 40 (11) : 1824 - 1828
  • [28] ALTERATIONS IN BRAIN PHOSPHORUS METABOLITE CONCENTRATIONS ASSOCIATED WITH AREAS OF HIGH SIGNAL INTENSITY IN WHITE MATTER AT MR IMAGING
    SAPPEYMARINIER, D
    DEICKEN, RF
    FEIN, G
    CALABRESE, G
    HUBESCH, B
    VANDYKE, C
    DILLON, WP
    DAVENPORT, L
    MEYERHOFF, DJ
    WEINER, MW
    RADIOLOGY, 1992, 183 (01) : 247 - 256
  • [29] Dynamic subtraction MR imaging of cirrhotic liver: Assessment of high signal intensity lesions on nonenhanced T1-weighted images
    Yu, J
    Kim, YH
    Rofsky, NM
    RADIOLOGY, 2002, 225 : 634 - 634
  • [30] Heschl and superior temporal gyri: Low signal intensity of the cortex on T2-weighted MR images of the normal brain
    Yoshiura, T
    Higano, S
    Rubio, A
    Shrier, DA
    Kwok, WE
    Iwanaga, S
    Numaguchi, Y
    RADIOLOGY, 2000, 214 (01) : 217 - 221