Early Detection For Cu Wire Bonding Corrosion Using Accelerated Autoclave Reliability Test

被引:0
|
作者
Tai, C. T. [1 ]
Lim, H. Y. [1 ]
Teo, C. H. [1 ]
Swee, Audrey P. J. [1 ]
机构
[1] Infineon Technol Malaysia Sdn Bhd, Batu Berendam 73500, Melaka, Malaysia
关键词
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Rapid change of technologies, coupled with increase in demand of quality and reliability, development speed is the top challenge to have market win for semiconductor industries. As semiconductor is moving towards copper wire bonding, failure associated with reliability is critical, While reliability results take time to wait for the cycles to complete in order to have next decision or improvement. In this paper, the study is initiated due to corrosion failure in Autoclave 96hours. Corrosion associated with copper wire bonding is considered one of the challenges to solve in term of reliability risk which happened at very low ppm rate. The focus on this paper is on early detection for corrosion associate with Cu wire on Aluminum pad, Therefore, establishment of early detection method in detecting/checking corrosion would significantly shorten the development cycle as complete package with normal Autoclave 96hours reliability stress. The development of Autoclave test on non-encapsulation samples was developed based on assumption that mould compound is not the source of chlorine contamination to aluminum metallization corrosion, Without mould compound encapsulation, corrosion rate between copper wire and Aluminum bondpad in moisture environment would expect to be accelerated. This hypothesis is then proven in the experiment of non-encapsulation stripes with Autoclave 1hours, 2hours, 4hours and 6hours, The study shows that Autoclave 1hour is not enough to provoke the corrosion whereas Autoclave 2hours onwards is found to be corresponding and tally with moulded AC96 hours result where we observed similar corrosion signs - corrosion with crack mechanism and exposed metal stack. From the EDX mapping analysis on the corroded pad, presence of Cl on the bondpad is still persistence as similar observation on Autoclave 96 hours corroded pad. By means of the failure replication in Autoclave 2hours test is successful and the failure mechanism was successfully demonstrated. With the findings in hypothesis study, the Autoclave 2hours was used as the stress test to investigate the corrosion and the failure rate from each category actually tally with the final finding in DOE and it shows significant reduction in corrosion rate during Autoclave short duration test for the dominant corrosion influencing factor. In the final of the experiment, a proper full DOE leg was run with the highly dominant contributor of corrosion and the encapsulation units was send for Autoclave 96 hours as per standard JEDEC requirement, the results show positive with no sign of corrosion, the root cause was then nailed. As a conclusion, result of Autoclave 2hours on non-encapsulation stripes arc compatible with conventional Autoclave 96 hours in revealing a sign of corrosion in this case study and it is proven to be a reliable result, This newly developed method not only save the reliability cycle time compared to the conventional Autoclave 96 hours, it also save in term of the product assembly from processing in End of Line which normally easily takes up to 7 days. If all round up together this new method actually save the overall cycle time of minimum 30 days however in actual only need 2 days to get the DOE results after Autoclave 2hours implementation.
引用
收藏
页码:309 / 312
页数:4
相关论文
共 50 条
  • [21] Process Optimization and Reliability Study for Cu Wire Bonding Advanced Nodes
    Qin, Ivy
    Xu, Hui
    Milton, Basil
    Mendoza, Nestor
    Clauberg, Horst
    Chylak, Bob
    Abe, Hidenori
    Kang, Dongchul
    Endo, Yoshinori
    Osaka, Masahiko
    Nakamura, Shinya
    2014 IEEE 64TH ELECTRONIC COMPONENTS AND TECHNOLOGY CONFERENCE (ECTC), 2014, : 1523 - 1528
  • [22] Cu Wire Bonding: Reliability Improvement for High Temperature in Plastic Packages
    Passagrilli, C.
    Vitali, B.
    Tiziani, R.
    Azzopardi, C.
    2009 EUROPEAN MICROELECTRONICS AND PACKAGING CONFERENCE (EMPC 2009), VOLS 1 AND 2, 2009, : 167 - +
  • [23] Corrosion Behavior of Cu-Al Intermetallic Compounds in Copper Wire Bonding in Chloride-containing Accelerated Humidity Testing
    Liu, Dong
    Then, Edward
    Chen, Haibin
    Wu, Jingshen
    2016 IEEE 66TH ELECTRONIC COMPONENTS AND TECHNOLOGY CONFERENCE (ECTC), 2016, : 629 - 636
  • [24] Corrosion Performance of Cu Bonded Grounding-Electrode by Accelerated Corrosion Test
    Choi, Sun Kyu
    Kim, Kyung Chul
    CORROSION SCIENCE AND TECHNOLOGY-KOREA, 2018, 17 (05): : 211 - 217
  • [25] Comparison and mechanism of electromigration reliability between Cu wire and Au wire bonding in molding state
    Yahong Du
    Li-Yin Gao
    Daquan Yu
    Zhi-Quan Liu
    Journal of Materials Science: Materials in Electronics, 2020, 31 : 2967 - 2975
  • [26] Comparison and mechanism of electromigration reliability between Cu wire and Au wire bonding in molding state
    Du, Yahong
    Gao, Li-Yin
    Yu, Daquan
    Liu, Zhi-Quan
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN ELECTRONICS, 2020, 31 (04) : 2967 - 2975
  • [27] Numerical Multiphysics Model for Cu-Al Wire Bond Corrosion Subjected to Highly-Accelerated Stress Test
    Lall, Pradeep
    Luo, Yihua
    Luu Nguyen
    2018 IEEE 68TH ELECTRONIC COMPONENTS AND TECHNOLOGY CONFERENCE (ECTC 2018), 2018, : 1628 - 1638
  • [28] An investigation on Cu Wire Bond Corrosion and Mitigation Technique for Automotive Reliability
    Tai, C. T.
    Lim, H. Y.
    Teo, C. H.
    Swee, Audrey P. J.
    2012 35TH IEEE/CPMT INTERNATIONAL ELECTRONICS MANUFACTURING TECHNOLOGY SYMPOSIUM (IEMT), 2012,
  • [29] Accelerated reliability testing of Cu-Al bimetallic contact by a micropattern corrosion testing platform for wire bond device application
    Kumar, Goutham Issac Ashok
    Alptekin, John
    Caperton, Joshua
    Salunke, Ashish
    Chyan, Oliver
    METHODSX, 2021, 8
  • [30] Key Factors in Cu Wire Bonding Reliability: Remnant Aluminum and Cu/Al IMC Thickness
    Premkumar, J.
    Kumar, B. Senthil
    Madhu, M.
    Sivakumar, M.
    Song, K. Y. James
    Wong, Y. M.
    EPTC: 2008 10TH ELECTRONICS PACKAGING TECHNOLOGY CONFERENCE, VOLS 1-3, 2008, : 971 - 975