Cover requirements of thermoplastic pipes used under highways

被引:17
|
作者
Kang, Junsuk [1 ]
Jung, Younghan [1 ]
Ahn, Yonghan [2 ]
机构
[1] Georgia So Univ, Dept Civil Engn & Construct Management, Statesboro, GA 30460 USA
[2] Western Carolina Univ, Dept Construct Management, Cullowhee, NC 28723 USA
关键词
Thermoplastic resin; Strength; Finite element analysis; Fill heights; FLEXIBLE PIPES; PERFORMANCE;
D O I
10.1016/j.compositesb.2013.06.025
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper summarizes the results of a research project that investigated the use of thermoplastic pipes, namely High-Density Polyethylene (HDPE) and Poly-vinyl Chloride (PVC), as cross-drains under highways. The study evaluated pipes ranging from 0.3 m (12 in.) to 1.5 m (60 in.) in diameter, under deep fills, minimum cover, and construction loads. The project consisted of three major phases: (1) a comprehensive literature review, (2) an analytical study into the allowable fill heights for thermoplastic pipes, and (3) a field study to observe the installation and performance of the pipe in service conditions. This study concluded with recommendations for how and when thermoplastic pipe should be installed in order for it to perform as intended. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:184 / 192
页数:9
相关论文
共 50 条