Phased array ultrasonic imaging using angle beam virtual source full matrix capture-total focusing method

被引:35
|
作者
Sumana [1 ]
Kumar, Anish [1 ]
机构
[1] Indira Gandhi Ctr Atom Res, Homi Bhabha Natl Inst, Nondestruct Evaluat Div, Met & Mat Grp, Kalpakkam 603102, Tamil Nadu, India
关键词
Phased array; FMC; TFM; SAFT; Virtual source; SYNTHETIC-APERTURE; TRANSDUCER; ELEMENTS;
D O I
10.1016/j.ndteint.2020.102324
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Full matrix capture coupled with total focusing method (FMC-TFM) is one of the most advanced and popular phased array ultrasonic techniques used to achieve simultaneous focusing at all depths in a specimen. In case of conventional FMC-TFM technique, a single element is used for transmission that limits the transmitted energy. This leads to reduced sensitivity at larger depths particularly in attenuating materials such as austenitic alloys. An Angle Beam Virtual Source FMC (ABVSFMC) method is proposed in the present paper to enhance the sensitivity by increasing the transmitted energy with specific directivity. The methodology utilizes apertures of a few elements to obtain a diverging beam by focusing very near to the top surface (virtual source). Further, as a group of elements is used in transmission, a divergent beam with specific directivity can be achieved without using a wedge. In reception, all the available channels are used and an algorithm similar to the Total Focusing Method (TFM) is used to reconstruct the image. The methodology is demonstrated by imaging the tip diffracted signals obtained from slot type planar defects at various depths in the range of 25-175 mm in a 200 mm thick nickel base alloy forging.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Large-area surface imaging methods using ultrasonic Rayleigh waves, phased array and full matrix capture for non-destructive testing
    Hoyle, C.
    Sutcliffe, M.
    Charlton, P.
    Mosey, S.
    INSIGHT, 2019, 61 (07) : 367 - +
  • [32] Quantitative Method of Rail Flaws Based on Ultrasonic Phased Array and Total Focusing DAC Mappings
    Li T.
    Shi Y.
    Chen F.
    Hu H.
    Li X.
    Jixie Gongcheng Xuebao/Journal of Mechanical Engineering, 2021, 57 (18): : 32 - 41
  • [33] Discretized tensor-based model of total focusing method: A sparse regularization approach for enhanced ultrasonic phased array imaging
    Zhao, Zhiyuan
    Liu, Lishuai
    Liu, Wen
    Teng, Da
    Xiang, Yanxun
    Xuan, Fu-Zhen
    NDT & E INTERNATIONAL, 2024, 141
  • [34] Ultrasonic Phased Array Sparse TFM Imaging Based on Virtual Source and Phase Coherent Weighting
    Yang, Jin
    Luo, Lin
    Yang, Kai
    Zhang, Yu
    IEEE ACCESS, 2020, 8 : 185609 - 185618
  • [35] The Wavenumber Algorithm for Full-Matrix Imaging Using an Ultrasonic Array
    Hunter, Alan J.
    Drinkwater, Bruce W.
    Wilcox, Paul D.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2008, 55 (11) : 2450 - 2462
  • [36] Total focusing imaging in anisotropic additive manufacturing components using ultrasonic array
    Xu N.
    Xu L.
    He F.
    Beijing Hangkong Hangtian Daxue Xuebao/Journal of Beijing University of Aeronautics and Astronautics, 2023, 49 (05): : 1063 - 1070
  • [37] Investigations on imaging and sizing of defects using ultrasonic phased array and the synthetic aperture focusing technique
    Satyanarayan, L.
    Rajkumar, K. V.
    Sharma, G. K.
    Jayakumar, T.
    Krishnamurthy, C. V.
    Balasubramaniam, Krishnan
    Raj, Baldev
    INSIGHT, 2009, 51 (07) : 384 - 390
  • [38] A multiscale residual U-net architecture for super-resolution ultrasonic phased array imaging from full matrix capture data
    Liu, Lishuai
    Liu, Wen
    Teng, Da
    Xiang, Yanxun
    Xuan, Fu-Zhen
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2023, 154 (04): : 2044 - 2054
  • [39] Ultrasonic guided wave phased array pulse compression full focus defect imaging method
    Xu, Caibin
    Zuo, Hao
    Chen, Yixin
    Zhendong yu Chongji/Journal of Vibration and Shock, 2024, 43 (11): : 50 - 57
  • [40] Quantitative crack detection by ultrasonic imaging with the full-mode total focusing method
    Jin S.
    Liu C.
    Shi S.
    Liao J.
    Lin L.
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2021, 42 (01): : 183 - 190