A study on safe forceps grip force for the intestinal tract using haptic technology

被引:1
|
作者
Yatabe, Kentaro [1 ]
Ozawa, Soji [1 ]
Oguma, Junya [2 ]
Hiraiwa, Shinichiro [3 ]
Tomita, Sakura [3 ]
Matsunaga, Takuya [4 ]
Togashi, Nobuyuki [4 ]
Yokoyama, Minoru [5 ]
Shimono, Tomoyuki [6 ]
Ohnishi, Kouhei [7 ]
机构
[1] Tokai Univ, Sch Med, Dept Gastroenterol Surg, 143 Shimokasuya, Isehara, Kanagawa 2591193, Japan
[2] Natl Canc Ctr, Dept Esophageal Surg, Tokyo, Japan
[3] Tokai Univ, Sch Med, Dept Pathol, Isehara, Kanagawa, Japan
[4] Kanagawa Inst Ind Sci & Technol, Kawasaki, Kanagawa, Japan
[5] Yokohama Natl Univ, Grad Sch Engn, Yokohama, Kanagawa, Japan
[6] Yokohama Natl Univ, Fac Engn, Yokohama, Kanagawa, Japan
[7] Keio Univ, Hapt Res Ctr, Kawasaki, Kanagawa, Japan
关键词
haptics; haptic forceps; safety gripping force; robotic surgery;
D O I
10.1080/13645706.2020.1870500
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose The present study used haptic technology to determine the safe forceps grip force for preventing organ damage when handling the intestinal tract. Material and methods The small intestines of ten male beagle dogs (weighing 9.5-10 kg) were grasped with the entire forceps for one minute; the small intestines were then pulled out of the forceps and evaluated for damage. The force at which the shaft inside the forceps was pulled to close the tip of the forceps was defined as the grip force. Small intestine damage was classified into macroscopic (serosal defects, hemorrhage, hematomas, grip marks) and microscopic (damage layer to the mucosa, submucosa/muscularis mucosa, inner orbicularis muscle, external longitudinal muscle, serosa/subserosa). Grip marks and damage layer to the serosa/subserosa have been considered as acceptable safety margins when grasping the small intestines of beagle dogs. Results The macroscopic findings showed that the maximum grip force that produced a 0% incidence of hemorrhage and hematoma was 15 N. At the microscopic level, the maximum grip force that produced a 0% incidence of external longitudinal muscle injury was 15 N, respectively. Conclusions A grip force of 15 N does not damage the small intestines of beagle dogs.
引用
收藏
页码:573 / 579
页数:7
相关论文
共 33 条
  • [21] Phylogenetic Fingerprinting of the Faecal Microbiota in IBD-Patients Using the Human Intestinal Tract (HIT) Chip Approach: A Twin Study
    Jonkers, Daisy
    Zoetendal, Erwin G.
    Romberg, Marielle
    Hesselink, Martine
    de Vos, Willem
    Masclee, Ad
    Pierik, Marie J.
    GASTROENTEROLOGY, 2009, 136 (05) : A21 - A21
  • [22] Identifying volatile metabolite signatures for the diagnosis of bacterial respiratory tract infection using electronic nose technology: A pilot study
    Lewis, Joseph M.
    Savage, Richard S.
    Beeching, Nicholas J.
    Beadsworth, Mike B. J.
    Feasey, Nicholas
    Covington, James A.
    PLOS ONE, 2017, 12 (12):
  • [23] Symptom profile of patients receiving antibiotics for upper respiratory tract infections in general practice: an observational study using smartphone technology
    Jiwa, Moyez
    Krejany, Catherine J.
    Kanjo, Epi
    Leeb, Alan
    Peters, J.
    FAMILY PRACTICE, 2019, 36 (05) : 560 - 567
  • [24] Comparative Study of Shear Wave Velocities Using Acoustic Radiation Force Impulse Technology in Hepatocellular Carcinoma: The Extent of Radiofrequency Ablation
    Kang, Jiyoung
    Kwon, Heejin
    Cho, Jinhan
    Oh, Jongyoung
    Nam, Kyungjin
    Yoon, Seongkuk
    Kang, Myongjin
    Lee, Sungwook
    Han, Sangyeong
    GUT AND LIVER, 2012, 6 (03) : 362 - 367
  • [25] Dietary protein concentration affects intestinal microbiota of adult cats: a study using DGGE and qPCR to evaluate differences in microbial populations in the feline gastrointestinal tract
    Lubbs, D. C.
    Vester, B. M.
    Fastinger, N. D.
    Swanson, K. S.
    JOURNAL OF ANIMAL PHYSIOLOGY AND ANIMAL NUTRITION, 2009, 93 (01) : 113 - 121
  • [26] DIAGNOSTIC PERFORMANCE OF POINT SHEAR WAVE ELASTOGRAPHY USING ACOUSTIC RADIATION FORCE IMPULSE TECHNOLOGY IN PERIPHERAL PULMONARY CONSOLIDATIONS: A FEASIBILITY STUDY
    Alhyari, Amjad
    Goerg, Christian
    Dietrich, Christoph Frank
    Trenker, Corinna
    Ludwig, Michael
    Zadeh, Ehsan Safai
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2022, 48 (05): : 778 - 785
  • [27] Experimental study on the stability of an impedance-type force-feedback architecture based on an augmented-state observer for a haptic system under time delay using a LMI approach
    Dang, Quoc Viet
    Vermeiren, Laurent
    Dequidt, Antoine
    Dambrine, Michel
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART I-JOURNAL OF SYSTEMS AND CONTROL ENGINEERING, 2016, 230 (01) : 58 - 71
  • [28] Diagnostic Performance of Point Shear Wave Elastography (pSWE) Using Acoustic Radiation Force Impulse (ARFI) Technology in Mesenteric Masses: A Feasibility Study
    Alhyari, Amjad
    Goerg, Christian
    Dietrich, Christoph Frank
    Kawohl, Svenja
    Safai Zadeh, Ehsan
    DIAGNOSTICS, 2022, 12 (02)
  • [29] A study of endoscopic retrograde cholangiopancreatography- related procedures for postoperative reconstructed intestinal tract using short-type single-balloon enteroscopy in our hospital
    Sakuma, Dai
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2017, 32 : 220 - 220
  • [30] Tailored Low Voltage Zones Ablation Using Contact Force Sensing Technology in Patients With Persistent Atrial Fibrillation (TWEET-AF): A Pilot Study
    DAmbrosio, Gabriele
    Raffa, Santi
    Romano, Silvio
    Frommhold, Markus
    Alothman, Obaida
    Borisov, Georgi
    Issa, Karam
    Penco, Maria
    Geller, Christoph
    CIRCULATION, 2020, 142