A study on safe forceps grip force for the intestinal tract using haptic technology

被引:1
|
作者
Yatabe, Kentaro [1 ]
Ozawa, Soji [1 ]
Oguma, Junya [2 ]
Hiraiwa, Shinichiro [3 ]
Tomita, Sakura [3 ]
Matsunaga, Takuya [4 ]
Togashi, Nobuyuki [4 ]
Yokoyama, Minoru [5 ]
Shimono, Tomoyuki [6 ]
Ohnishi, Kouhei [7 ]
机构
[1] Tokai Univ, Sch Med, Dept Gastroenterol Surg, 143 Shimokasuya, Isehara, Kanagawa 2591193, Japan
[2] Natl Canc Ctr, Dept Esophageal Surg, Tokyo, Japan
[3] Tokai Univ, Sch Med, Dept Pathol, Isehara, Kanagawa, Japan
[4] Kanagawa Inst Ind Sci & Technol, Kawasaki, Kanagawa, Japan
[5] Yokohama Natl Univ, Grad Sch Engn, Yokohama, Kanagawa, Japan
[6] Yokohama Natl Univ, Fac Engn, Yokohama, Kanagawa, Japan
[7] Keio Univ, Hapt Res Ctr, Kawasaki, Kanagawa, Japan
关键词
haptics; haptic forceps; safety gripping force; robotic surgery;
D O I
10.1080/13645706.2020.1870500
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose The present study used haptic technology to determine the safe forceps grip force for preventing organ damage when handling the intestinal tract. Material and methods The small intestines of ten male beagle dogs (weighing 9.5-10 kg) were grasped with the entire forceps for one minute; the small intestines were then pulled out of the forceps and evaluated for damage. The force at which the shaft inside the forceps was pulled to close the tip of the forceps was defined as the grip force. Small intestine damage was classified into macroscopic (serosal defects, hemorrhage, hematomas, grip marks) and microscopic (damage layer to the mucosa, submucosa/muscularis mucosa, inner orbicularis muscle, external longitudinal muscle, serosa/subserosa). Grip marks and damage layer to the serosa/subserosa have been considered as acceptable safety margins when grasping the small intestines of beagle dogs. Results The macroscopic findings showed that the maximum grip force that produced a 0% incidence of hemorrhage and hematoma was 15 N. At the microscopic level, the maximum grip force that produced a 0% incidence of external longitudinal muscle injury was 15 N, respectively. Conclusions A grip force of 15 N does not damage the small intestines of beagle dogs.
引用
收藏
页码:573 / 579
页数:7
相关论文
共 33 条
  • [1] The Virtual Mitten: A Novel Interaction Paradigm for Visuo-Haptic Manipulation of Objects Using Grip Force
    Achibet, Merwan
    Marchal, Maud
    Argelaguet, Ferran
    Lecuyer, Anatole
    2014 IEEE SYMPOSIUM ON 3D USER INTERFACES (3DUI), 2014, : 59 - 66
  • [2] Force quantification and simulation of pedicle screw tract palpation using direct visuo-haptic volume rendering
    Zoller, Esther I.
    Faludi, Balazs
    Gerig, Nicolas
    Jost, Gregory F.
    Cattin, Philippe C.
    Rauter, Georg
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2020, 15 (11) : 1797 - 1805
  • [3] Force quantification and simulation of pedicle screw tract palpation using direct visuo-haptic volume rendering
    Esther I. Zoller
    Balázs Faludi
    Nicolas Gerig
    Gregory F. Jost
    Philippe C. Cattin
    Georg Rauter
    International Journal of Computer Assisted Radiology and Surgery, 2020, 15 : 1797 - 1805
  • [4] A Method to Study Precision Grip Control in Viscoelastic Force Fields Using a Robotic Gripper
    Lambercy, Olivier
    Metzger, Jean-Claude
    Santello, Marco
    Gassert, Roger
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2015, 62 (01) : 39 - 48
  • [5] Pilot Study for Grip Force Prediction Using Neural Signals from Different Brain Regions
    Bataineh, Mohammad
    McNiel, David
    Choi, John
    Hessburg, John
    Francis, Joseph
    2016 32ND SOUTHERN BIOMEDICAL ENGINEERING CONFERENCE (SBEC), 2016, : 19 - 20
  • [6] A pilot study to assess the feasibility and accuracy of using haptic technology to occlude digital dental models
    Wu, Wen
    Cen, Yuhai
    Hong, Yang
    Keeling, Andrew
    Khambay, Balvinder
    JOURNAL OF DENTISTRY, 2016, 46 : 54 - 60
  • [7] Feasibility study on the retention of superporous hydrogel composite polymer in the intestinal tract of man using scintigraphy
    Dorkoosh, FA
    Stokkel, MPM
    Blok, D
    Borchard, G
    Rafiee-Tehrani, A
    Verhoef, JC
    Junginger, HE
    JOURNAL OF CONTROLLED RELEASE, 2004, 99 (02) : 199 - 206
  • [8] Is childhood enuresis a failure of renal tract maturation? A study using novel metabonomic technology
    Taylor, CJ
    Foxall, PJ
    Mouriquand, P
    JOURNAL OF UROLOGY, 2003, 169 (04): : 170 - 170
  • [9] Ultrasonographic elastography of the breast using acoustic radiation force impulse technology: preliminary study
    Tozaki, Mitsuhiro
    Isobe, Sachiko
    Yamaguchi, Miki
    Ogawa, Yukari
    Homma, Kanako
    Saito, Masahiro
    Joo, Chanwoong
    Fukuma, Eisuke
    JAPANESE JOURNAL OF RADIOLOGY, 2011, 29 (06) : 452 - 456
  • [10] Ultrasonographic elastography of the breast using acoustic radiation force impulse technology: preliminary study
    Mitsuhiro Tozaki
    Sachiko Isobe
    Miki Yamaguchi
    Yukari Ogawa
    Kanako Homma
    Masahiro Saito
    Chanwoong Joo
    Eisuke Fukuma
    Japanese Journal of Radiology, 2011, 29 : 452 - 456