Energy and exergy investigation of a hybrid refrigeration system activated by mid/low-temperature heat source

被引:5
|
作者
Sun, Liuli [1 ]
Han, Wei [2 ]
Jin, Hongguang [2 ]
机构
[1] State Nucl Power Technol R&D Ctr, Beijing 102209, Peoples R China
[2] Chinese Acad Sci, Inst Engn Thermophys, Beijing 100190, Peoples R China
基金
中国国家自然科学基金;
关键词
Hybrid refrigeration system; Mid/low-temperature heat source; Ammonia-water working fluid; Exergy analysis; GAX CYCLE; ABSORPTION; POINT;
D O I
10.1016/j.applthermaleng.2015.08.061
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study proposes a hybrid refrigeration system activated by mid/low-temperature sensible heat source with ammonia water (NH3-H2O) binary mixture as working fluid. The heat source is utilized in cascade in the hybrid system. This heat source is used to generate a superheated NH3-H2O mixture vapor, which is used successively in the power generation and compression subsystem and in the absorption and rectification subsystem to produce refrigerant vapor. Energy and exergy analysis results show that the Coefficient Of Performance, System Coefficient Of Performance, and exergy efficiency of the proposed system in the base case are 0.722, 0.485, and 23.1%, respectively. Effects of turbine inlet pressure, turbine outlet pressure, and solution concentration in the power generation subsystem on system performance are examined. This study provides a new refrigeration method to effectively utilize mid/low-temperature sensible heat. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:913 / 923
页数:11
相关论文
共 50 条
  • [21] Mid-/low-temperature energy in China
    Zhao J.
    Li Y.
    Li H.
    Zhong S.
    Ma L.
    Li W.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2022, 43 (02): : 250 - 260
  • [22] Simulation model of a low-temperature supermarket refrigeration system
    Getu, Haile-Michael
    Bansal, Pradeep Kumar
    HVAC&R RESEARCH, 2006, 12 (04): : 1117 - 1139
  • [23] Performance investigation on Organic Rankine Cycle from a low-temperature heat source
    Malwe, Prateek D.
    Gawali, Bajirao S.
    Salunke, Avinash
    Sharma, Kamal
    Salunkhe, Ankur
    Siddiqui, Md Irfanul Haque
    Mehta, Bhavin
    Tejani, Ghanshyam
    CASE STUDIES IN THERMAL ENGINEERING, 2025, 68
  • [24] Performance simulation and exergy analysis of a hybrid source heat pump system with low GWP refrigerants
    Wu, Di
    Hu, Bin
    Wang, R. Z.
    RENEWABLE ENERGY, 2018, 116 : 775 - 785
  • [25] HEAT PUMPS AND LOW-TEMPERATURE ENERGY
    LEHMANN, G
    REVUE GENERALE DE THERMIQUE, 1976, 15 (178): : 893 - 894
  • [26] INVESTIGATION OF LOW-TEMPERATURE REGENERATION OF ACTIVATED CARBON
    AMICARELLI, V
    BALDASSARRE, G
    LIBERTI, L
    JOURNAL OF THERMAL ANALYSIS, 1980, 18 (01): : 155 - 160
  • [27] Advanced exergy investigation of a combined cooling and power system with low-temperature geothermal heat as a prime mover for district cooling applications
    Mohammadi, Zahra
    Musharavati, Farayi
    Ahmadi, Pouria
    Rahimi, Shayan
    Khanmohammadi, Shoaib
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2022, 51
  • [28] Thermodynamic Energy and Exergy Analysis of Low-Temperature Combustion Strategies
    Shirvani, Saeid
    Shirvani, Sasan
    Reitz, Rolf
    Salehi, Fatemeh
    SAE INTERNATIONAL JOURNAL OF ENGINES, 2021, 14 (03) : 345 - 367
  • [29] Simulation investigation of a heat pump, operating on a low-temperature source of heat and a constant condensation pressure
    Rachkovskiy, N. O.
    Tatarenko, Iu V.
    Mitropov, V. V.
    Naumova, O. S.
    Bordashev, K. A.
    2ND INTERNATIONAL SCIENTIFIC AND PRACTICAL CONFERENCE ON INNOVATIONS IN ENGINEERING AND TECHNOLOGY, 2019, 656
  • [30] Working fluids for low-temperature heat source
    Lakew, Amlaku Able
    Bolland, Olav
    APPLIED THERMAL ENGINEERING, 2010, 30 (10) : 1262 - 1268