Associations Between the Time in Hypoglycemia and Hypoglycemia Awareness Status in Type 1 Diabetes Patients Using Continuous Glucose Monitoring Systems

被引:17
|
作者
Lin, Yu Kuei [1 ]
Groat, Danielle [2 ]
Chan, Owen [1 ]
Hung, Man [3 ]
Sharma, Anu [1 ]
Varner, Michael W. [4 ]
Gouripeddi, Ramkiran [2 ]
Facelli, Julio C. [2 ]
Fisher, Simon J. [1 ]
机构
[1] Univ Utah, Sch Med, Dept Internal Med, Div Endocrinol Metab & Diabet, Salt Lake City, UT USA
[2] Univ Utah, Dept Biomed Informat, Salt Lake City, UT USA
[3] Univ Utah, Sch Med, Study Design & Biostat Ctr, Ctr Clin & Translat Sci, Salt Lake City, UT USA
[4] Univ Utah, Sch Med, Dept Obstet & Gynecol, Salt Lake City, UT 84132 USA
关键词
Hypoglycemia; Impaired awareness of hypoglycemia; Continuous glucose monitoring; Type; 1; diabetes; IMPAIRED AWARENESS; GLYCEMIC THRESHOLDS; INSULIN INJECTIONS; AUTONOMIC FAILURE; ADULTS; COUNTERREGULATION; MULTICENTER; CONSENSUS; SYMPTOMS;
D O I
10.1089/dia.2020.0016
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background:Continuous glucose monitoring (CGM) systems help reduce hypoglycemia in patients with type 1 diabetes (T1D). It remains unclear whether T1D patients with impaired awareness of hypoglycemia (IAH) continue to develop more hypoglycemia than those with normal hypoglycemia awareness (NA) despite CGM use. Materials and Methods:For this cross-sectional observational study, 99 T1D patients using real-time CGMs for >= 86% of time were recruited. Fifty and 49 patients were found to have NA and IAH (based on the Clarke questionnaire), respectively. Two-week CGM hypoglycemia data were collected. Results:IAH was associated with greater percentages of CGM values <70 and <54 mg/dL (P = 0.012,P = 0.004) compared to NA. Clarke scores correlated positively with the percentage of CGM values <70 and <54 mg/dL (P = 0.013,P = 0.004). IAH was also related to more events with glucose <70 and <54 mg/dL determined either with at >= 1 time point (P = 0.048,P = 0.003) or lasting >= 20 min (P = 0.016,P = 0.004). IAH patients presented with more day-time events with glucose <54 mg/dL (P = 0.015), nocturnal events with glucose levels <70 and <54 mg/dL (P = 0.009,P = 0.007) and longer day-time event duration with glucose levels <70 and <54 mg/dL (P < 0.001,P = 0.006), respectively. Conclusions:T1D patients with IAH continue to experience more hypoglycemia despite dedicated CGM use.
引用
收藏
页码:787 / 793
页数:7
相关论文
共 50 条
  • [41] The decision not to drive during hypoglycemia in patients with type 1 and type 2 diabetes, according to hypoglycemia awareness
    Stork, Alexander D.
    Van Haeften, Timon W.
    Veneman, Thiemo F.
    DIABETES, 2007, 56 : A44 - A44
  • [42] Analysis of Hemodialysis-Associated Hypoglycemia in Patients with Type 2 Diabetes Using a Continuous Glucose Monitoring System
    Jung, Hye Seung
    Kim, Hong Il
    Kim, Min Joo
    Yoon, Ji Won
    Ahn, Hwa Young
    Cho, Young Min
    Oh, Kook-Hwan
    Joo, Kwon Wook
    Lee, Jung Geon
    Kim, Seong Yeon
    Park, Kyong Soo
    DIABETES TECHNOLOGY & THERAPEUTICS, 2010, 12 (10) : 801 - 807
  • [43] The decision not to drive during hypoglycemia in patients with type 1 and type 2 diabetes according to hypoglycemia awareness
    Stork, Alexander D. M.
    van Haeften, Timon W.
    Veneman, Thiemo F.
    DIABETES CARE, 2007, 30 (11) : 2822 - 2826
  • [44] SELF BLOOD GLUCOSE MONITORING UNDERESTIMATES HYPERGLYCEMIA AND HYPOGLYCEMIA AS COMPARED TO CONTINUOUS GLUCOSE MONITORING IN TYPE 1 AND TYPE 2 DIABETES
    Mangrola, Devna
    Cox, Christine
    Furman, Arianne S.
    Krishnan, Sridevi
    Karakas, Sidika E.
    ENDOCRINE PRACTICE, 2018, 24 (01) : 47 - 52
  • [45] Continuous glucose monitoring reveals hypoglycemia risk in elderly patients with type 2 diabetes mellitus
    Ishikawa, Takahiro
    Koshizaka, Masaya
    Maezawa, Yoshiro
    Takemoto, Minoru
    Tokuyama, Yoshiharu
    Saito, Toshihiro
    Yokote, Koutaro
    JOURNAL OF DIABETES INVESTIGATION, 2018, 9 (01): : 69 - 74
  • [46] Hypoglycemia unawareness in type 1 diabetes patients using intermittent continuous glucose monitoring: Identification of risk factors and glycemic patterns
    Vieira, Ines H.
    Barros, Luisa M.
    Baptista, Carla F.
    Melo, Miguel
    Rodrigues, Dircea M.
    Paiva, Isabel M.
    DIABETES & METABOLIC SYNDROME-CLINICAL RESEARCH & REVIEWS, 2022, 16 (06)
  • [47] HEART RATE VARIABILITY DURING HYPOGLYCEMIA IN PATIENTS WITH TYPE 1 DIABETES AND IMPAIRED AWARENESS OF HYPOGLYCEMIA
    Koeneman, M.
    Bekkink, M. Olde
    Bredie, S. J.
    de Galan, B. E.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2019, 21 : A115 - A115
  • [48] Hypoglycemic Exposure and Risk of Asymptomatic Hypoglycemia in Type 1 Diabetes Assessed by Continuous Glucose Monitoring
    Henriksen, Marie Moth
    Andersen, Henrik Ullits
    Thorsteinsson, Birger
    Pedersen-Bjergaard, Ulrik
    JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2018, 103 (06): : 2329 - 2335
  • [49] Can continuous glucose monitoring technology reduce fear of hypoglycemia in people with type 1 diabetes?
    Talbo, Meryem K.
    Peters, Tricia
    Brazeau, Anne -Sophie
    Rabasa-Lhoret, Remi
    Yale, Jean -Francois
    POLISH ARCHIVES OF INTERNAL MEDICINE-POLSKIE ARCHIWUM MEDYCYNY WEWNETRZNEJ, 2022, 132 (02):
  • [50] The influence of risk factors on Hypoglycemia in type 1 diabetes assessed by continuous subcutaneous glucose monitoring
    Thorsteinsson, B
    Pramming, S
    Pedersen-Bjergaard, U
    DIABETES, 2003, 52 : A149 - A149