Blood compatibility and extended linearity of lactate enzyme electrode using poly(vinyl chloride) outer membranes

被引:19
|
作者
Kyrolainen, M [1 ]
Reddy, SM [1 ]
Vadgama, PM [1 ]
机构
[1] UNIV MANCHESTER,HOPE HOSP,DEPT CLIN BIOCHEM,SALFORD M6 8HD,LANCS,ENGLAND
关键词
blood; lactate enzyme electrode; poly(vinylchloride); membranes; amperometry;
D O I
10.1016/S0003-2670(97)87787-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A functionally haemocompatible lactate enzyme electrode system with an extended linear range has been developed. The electrode is based on classical amperometric detection of hydrogen peroxide produced by the enzyme lactate oxidase, immobilised in a glutaraldehyde matrix. The sensor system comprises an outer poly(vinyl chloride), PVC, membrane with incorporated non-ionic surfactant which acts both asa haemocompatible interface and a diffusion barrier, extending the sensor linear range up to at least 90 mM lactate. Electroactive interferents, such as ascorbate, urate and acetaminophen, are effectively excluded by the further use of an inner sulphonated polyether-ether sulphone/polyether sulphone membrane. Membrane composition and fabrication were investigated. The blood compatibility of the outer PVC membranes was evaluated by comparing sensitivity of the electrode before and after exposure to undiluted whole blood. Scanning electron microscopy (SEM) was also used to examine the membrane surface. Measurements of whole blood and plasma lactate concentrations when compared with those obtained with a standard lactate analyser gave, respectively, y=1.2x+050, r(2)=0.97, n=6 and y=0.89x+0.13, r(2)=0.96, n=20. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:281 / 289
页数:9
相关论文
共 50 条
  • [41] Determination of chlorine and dissolved oxygen in waters and of ascorbic acid in pharmaceuticals by iodimetric potentiometric titration using a plasticized poly(vinyl chloride) membrane electrode
    SanchezPedreno, C
    Ortuno, JA
    Hernandez, J
    ANALYTICA CHIMICA ACTA, 1996, 333 (1-2) : 107 - 113
  • [42] Enhancing compatibility and hydrophilicity of polysulfone/poly (ethylene-co-vinyl alcohol) copolymer blend ultrafiltration membranes using polyethylene glycol as hydrophilic additive and compatibilizer
    Kadanyo, Sania
    Gumbi, Nozipho N.
    Matindi, Christine N.
    Dlamini, Derrick S.
    Hu, Yunxia
    Cui, Zhenyu
    Wang, Hong
    Hu, Mengyang
    Li, Jianxin
    SEPARATION AND PURIFICATION TECHNOLOGY, 2022, 287
  • [43] Potentiometric back-titration of sulfate ion using a tetraphenylborate derivative as a titrant and a titrant-sensitive plasticized poly(vinyl chloride) membrane electrode
    T. Masadome
    Yasukazu Asano
    Fresenius' Journal of Analytical Chemistry, 1998, 362 : 423 - 425
  • [44] Potentiometric back-titration of sulfate ion using a tetraphenylborate derivative as a titrant and a titrant-sensitive plasticized poly(vinyl chloride) membrane electrode
    Masadome, T
    Asano, Y
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 362 (04): : 423 - 425
  • [45] MEDIATED AMPEROMETRIC DETECTION OF GLUCOSE-6-PHOSPHATE-DEHYDROGENASE AT A POLY(VINYL CHLORIDE) COVERED ELECTRODE USING 1,4-BENZOQUINONE AND DIAPHORASE
    TRELOAR, PH
    CHRISTIE, IM
    KANE, JW
    CRUMP, P
    NKOHKWO, AT
    VADGAMA, PM
    ELECTROANALYSIS, 1995, 7 (03) : 216 - 220
  • [46] DETERMINATION OF SODIUM IN PROCESSED FOODSTUFFS USING A BIS(12-CROWN-4) DERIVATIVE-BASED POLY(VINYL CHLORIDE) MEMBRANE-ELECTRODE
    BINSAAD, B
    DEVI, J
    JOURNAL OF THE SCIENCE OF FOOD AND AGRICULTURE, 1991, 56 (03) : 403 - 406
  • [47] CO2 absorption using gas-liquid membrane contactors made of highly porous poly(vinyl chloride) hollow fiber membranes
    Fashandi, Hossein
    Ghodsi, Ali
    Saghafi, Reza
    Zarrebini, Mohammad
    INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2016, 52 : 13 - 23
  • [48] POTENTIOMETRIC FLOW-INJECTION DETERMINATION OF BORON BY USING A FLOW-THROUGH TETRAFLUOROBORATE ION-SELECTIVE POLY(VINYL CHLORIDE) MEMBRANE-ELECTRODE
    IMATO, T
    YOSHIZUKA, T
    ISHIBASHI, N
    ANALYTICA CHIMICA ACTA, 1990, 233 (01) : 139 - 141
  • [49] CONTRIBUTION OF PLASTICIZER TO RESPONSE OF SURFACTANT-SELECTIVE PLASTICIZED POLY(VINYL CHLORIDE) MEMBRANE-ELECTRODE BY USING ION-SENSITIVE FIELD-EFFECT TRANSISTOR
    MASADOME, T
    WAKIDA, S
    KAWABATA, Y
    IMATO, T
    ISHIBASHI, N
    ANALYTICAL SCIENCES, 1992, 8 (01) : 89 - 90
  • [50] SEQUENTIAL DETERMINATION OF GLUTAMATE-OXALACETATE TRANSAMINASE AND GLUTAMATE-PYRUVATE TRANSAMINASE ACTIVITIES IN SERUM USING AN IMMOBILIZED BIENZYME-POLY(VINYL CHLORIDE) MEMBRANE-ELECTRODE
    KIHARA, K
    YASUKAWA, E
    HIROSE, S
    ANALYTICAL CHEMISTRY, 1984, 56 (11) : 1876 - 1880