Glycoprotein characterization combining intact protein and glycan analysis by capillary electrophoresis-electrospray ionization-mass spectrometry

被引:105
|
作者
Balaguer, Elvira
Neusuess, Christian [2 ]
机构
[1] Bruker Daltonik GmbH, D-28359 Bremen, Germany
[2] Univ Barcelona, Barcelona, Spain
关键词
D O I
10.1021/ac060376g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Glycosylated proteins play important roles in a large number of biological processes. Therefore, a complete characterization in terms of glycan structures and glycoform heterogeneity is needed. In this paper, a combined approach based on glycan and intact glycoprotein analysis by capillary zone electrophoresis-electrospray-mass spectrometry (CZE-ESI-MS) is presented. Based on a new capillary coating, a CZE-ESI-MS method for the separation and characterization of intact glycoproteins has been developed and compared to a method recently introduced for the characterization of erythropoietin. The excellent glycoform separation results in high-quality mass spectra, high dynamic range, and good sensitivity, allowing the correct characterization of minor glycan modifications. Additionally, a CZE-ESI-MS separation method for underivatized N-glycans has been developed. The separation of glycans differing in the degree of sialic acids and repeats of noncharged carbohydrates is achieved. The separation power of the method is demonstrated by obtaining mobility differences in glycans differing only by 16 Da. A time-of-flight mass spectrometer allowed the correct identification of the glycan composition based on high mass accuracy and resolution, identifying even minor modifications such as the exchange of "O" by "NH". An ion trap mass spectrometer provided structural information of the underivatized glycans from fragmentation spectra. The general applicability of both methods to glycoprotein analysis is illustrated for erythropoietin, fetuin, and alpha 1-acid glycoprotein. The results obtained by the glycan analysis allowed an unequivocal glyco-assignment to the masses obtained for the intact proteins as long as the protein backbone is well characterized. Furthermore, modifications found for intact proteins can be attributed to differences in the glycostructure.
引用
收藏
页码:5384 / 5393
页数:10
相关论文
共 50 条
  • [21] Comparison of sheathless and sheath-flow electrospray interfaces for the capillary electrophoresis-electrospray ionization-mass spectrometry analysis of peptides
    Sanz-Nebot, V
    Balaguer, E
    Benavente, F
    Barbosa, J
    ELECTROPHORESIS, 2005, 26 (7-8) : 1457 - 1465
  • [22] Determination of amino acids by capillary electrophoresis-electrospray ionization-mass spectrometry: An evaluation of different protein hydrolysis procedures
    Colnaghi Simionato, Ana V.
    Moraes, Edgar Perin
    Carrilho, Emanuel
    Maggi Tavares, Marina Franco
    Kenndler, Ernst
    ELECTROPHORESIS, 2008, 29 (10) : 2051 - 2058
  • [23] Development of capillary zone electrophoresis-electrospray ionization-mass spectrometry for the determination of lamotrigine in human plasma
    Zheng, J
    Jann, MW
    Hon, YY
    Shamsi, SA
    ELECTROPHORESIS, 2004, 25 (13) : 2033 - 2043
  • [24] Characterization of phenolic and other polar compounds in a lemon verbena extract by capillary electrophoresis-electrospray ionization-mass spectrometry
    Quirantes-Pine, Rosa
    Arraez-Roman, David
    Segura-Carretero, Antonio
    Fernandez-Gutierrez, Alberto
    JOURNAL OF SEPARATION SCIENCE, 2010, 33 (17-18) : 2818 - 2827
  • [25] Study of the electrical connection mechanism of sheathless interface for capillary electrophoresis-electrospray ionization-mass spectrometry
    Tie, Cai
    Zhang, De-Wen
    Chen, Hong-Xu
    Song, Sen-Lin
    Zhang, Xin-Xiang
    JOURNAL OF MASS SPECTROMETRY, 2012, 47 (11): : 1429 - 1434
  • [26] Validation of chiral capillary electrophoresis-electrospray ionization-mass spectrometry methods for ecstasy and methadone in plasma
    Schappler, Julie
    Guillarme, Davy
    Prat, Josiane
    Veuthey, Jean-Luc
    Rudaz, Serge
    ELECTROPHORESIS, 2008, 29 (10) : 2193 - 2202
  • [27] Metabolic Differentiation of Neuronal Phenotypes by Single-cell Capillary Electrophoresis-Electrospray Ionization-Mass Spectrometry
    Nemes, Peter
    Knolhoff, Ann M.
    Rubakhin, Stanislav S.
    Sweedler, Jonathan V.
    ANALYTICAL CHEMISTRY, 2011, 83 (17) : 6810 - 6817
  • [28] Determination of Glyphosate as cross-contaminant in a commercial herbicide by capillary electrophoresis-electrospray ionization-mass spectrometry
    Safarpour, H
    Asiaie, R
    ELECTROPHORESIS, 2005, 26 (7-8) : 1562 - 1566
  • [29] Highly Sensitive and Robust Capillary Electrophoresis-Electrospray Ionization-Mass Spectrometry: Interfaces, Preconcentration Techniques and Applications
    Wu, Huanming
    Tang, Keqi
    REVIEWS IN ANALYTICAL CHEMISTRY, 2020, 39 (01) : 45 - 55
  • [30] Virtual Quantification of Metabolites by Capillary Electrophoresis-Electrospray Ionization-Mass Spectrometry: Predicting Ionization Efficiency Without Chemical Standards
    Chalcraft, Kenneth R.
    Lee, Richard
    Mills, Casandra
    Britz-McKibbin, Philip
    ANALYTICAL CHEMISTRY, 2009, 81 (07) : 2506 - 2515