Feasibility analysis of a hot water solar system coupled to an absorption crossMark heat transformer

被引:7
|
作者
Ibarra-Bahena, J. [1 ]
Dehesa-Carrasco, U. [2 ]
Montiel-Gonzalez, M. [3 ]
Romero, R. J. [1 ]
Venegas-Reyes, E. [4 ]
机构
[1] Univ Autonoma Estado Morelos, Ctr Invest Ingn & Ciencias Aplicadas, Av Univ 1001, Cuernavaca 62209, Morelos, Mexico
[2] Inst Mexicano Tecnol Agua, Catedrat CONACyT, Paseo Cuauhnahuac 8532, Jiutepec 62550, Morelos, Mexico
[3] Univ Autonoma Estado Morelos, Fac Ciencias Quim & Ingn, Av Univ 1001, Cuernavaca 62209, Morelos, Mexico
[4] Ctr Invest Mat Avanzados CIMAV, Catedrat CONACyT, Victoria 147 Nte, Zona Ctr 34000, Durango, Mexico
关键词
Parabolic Trough Collectors; Absorption Heat Transformer; Thermal energy recovery; Water/Carrol mixture; SINGLE-STAGE; WASTE HEAT; PURIFICATION SYSTEM; COGENERATION SYSTEM; PRESSURE-DROP; GENERATOR; TEMPERATURE; DESALINATION; CYCLE; CONFIGURATIONS;
D O I
10.1016/j.applthermaleng.2016.05.140
中图分类号
O414.1 [热力学];
学科分类号
摘要
Parabolic Trough Collectors (PTC) provides thermal solar energy at medium temperature, and in order to increase the thermal level, the solar system can be coupled to upgrading-devices, such as Absorption Heat Transformers (AHT). In this paper, a feasibility analysis of the PTC system operating as thermal source of an AHT is described. The PTC and AHT units were tested and, based on the experimental data of each system, a heat transfer analysis was carried out in order to propose a single system. Two case studies were analysed: In the first, the evaporator temperature was close to the generator temperature (84.6 and 85.2 degrees C respectively) and a simultaneous flow from the heat source was used; in the second case, the evaporator temperature was lower than the generator temperature (79.6 and 86.7 degrees C respectively) and a serial flow from the heat source was proposed. Results show that, for the absorber temperature of 101 C, the calculated generator and evaporator heat loads were 1.50 and 1.34 kW respectively in Case 1, and 0.86 kW for both components in Case 2. For Case 1, the PTC system required 6.0 m(2) in order to provide two mass flows of 6.00 x 10(-02) and 535 x 10-02 kg/s for generator and evaporator at 89 C. For Case 2, one mass flow of 6.60 x 10(-02) kg/s at 89 C for generator and evaporator must be satisfied by a 3.7 m(2) PTC system. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1176 / 1185
页数:10
相关论文
共 50 条
  • [41] THERMAL ANALYSIS OF A SOLAR HOT WATER SYSTEM AND A STOCK TANK
    Moaveni, Saeed
    ES2009: PROCEEDINGS OF THE ASME 3RD INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY, VOL 2, 2009, : 769 - 776
  • [42] Design of an ORC system operating with solar heat and producing sanitary hot water
    Ksayer, E. Bou Lawz
    IMPACT OF INTEGRATED CLEAN ENERGY ON THE FUTURE OF THE MEDITERRANEAN ENVIRONMENT, 2011, 6 : 389 - 395
  • [43] A solar based system for integrated production of power, heat, hot water and cooling
    Gursoy, Mehmet
    Dincer, Ibrahim
    ENERGY, 2023, 282
  • [44] A Hybrid Solar–Geothermal Heat- and Hot-Water Supply System
    A. B. Alkhasov
    D. A. Alkhasova
    M. G. Dibirov
    Thermal Engineering, 2021, 68 : 564 - 569
  • [45] Application of a heat source system using solar energy with hot water storage
    Kuboki, Masatoshi
    Tanabe, Shin-ichi
    Togashi, Eisuke
    SUSTAINABLE BUILT ENVIRONMENT CONFERENCE 2019 TOKYO (SBE19TOKYO) - BUILT ENVIRONMENT IN AN ERA OF CLIMATE CHANGE: HOW CAN CITIES AND BUILDINGS ADAPT?, 2019, 294
  • [46] Investigation of the performance of a combined solar thermal heat pump hot water system
    Panaras, G.
    Mathioulakis, E.
    Belessiotis, V.
    SOLAR ENERGY, 2013, 93 : 169 - 182
  • [47] A new heat-pipe type solar domestic hot water system
    Mathioulakis, E
    Belessiotis, V
    SOLAR ENERGY, 2002, 72 (01) : 13 - 20
  • [48] Energy and exergy analysis of a double absorption heat transformer operating with water/lithium bromide
    Martinez, H.
    Rivera, W.
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2009, 33 (07) : 662 - 674
  • [49] Experiment and Simulation Study of Flow Rate of PV Coupled Solar Hot Water System
    Ji, Jie (jijie@ustc.edu.cn), 1600, Science Press (38):
  • [50] A hybrid system consisting of dye-sensitized solar cell and absorption heat transformer for electricity production and heat upgrading
    Ma, Liuyang
    Zhao, Qin
    Guo, Xinru
    Zhang, Houcheng
    Hu, Ziyang
    Hou, Shujin
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2021, 150 : 233 - 241