Transcatheter occlusion of the patent ductus arteriosus with Cook detachable coils

被引:82
|
作者
Tometzki, AJP
Arnold, R
Peart, I
Sreeram, N
Abdulhamed, JM
Godman, MJ
Patel, RG
Kitchiner, DJ
BuLock, FA
Walsh, KP
机构
[1] ROYAL MANCHESTER CHILDRENS HOSP,MANCHESTER M27 1HA,LANCS,ENGLAND
[2] ROYAL LIVERPOOL CHILDRENS HOSP,LIVERPOOL L7 7DG,MERSEYSIDE,ENGLAND
[3] BIRMINGHAM CHILDRENS HOSP,BIRMINGHAM,W MIDLANDS,ENGLAND
[4] PRINCE SULTAN CARDIAC CTR,RIYADH,SAUDI ARABIA
关键词
ductus arteriosus; transcatheter occlusion; Cook spring coils; coils;
D O I
10.1136/hrt.76.6.531
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective-To report initial experience with a new occlusion device for native and residual patent ductus arteriosus. Design-Descriptive study of consecutive non-randomised patients undergoing a new method of patent ductus arteriosus closure with detachable coils. Setting-Tertiary centres for paediatric cardiology. Patients-71 consecutive patients, aged 1.2-22 years, with a patent ductus arteriosus (PDA) underwent elective transcatheter closure. 45 had native PDAs (group A) with a minimum diameter of 1.0 mm-5.0 mm (median 2.0 mm). A further 26 had undergone one or more previous occlusion attempts (group B). Interventions-A total of 133 detachable (Cook) spring coils were successfully implanted in 70 patients. The procedure was performed transvenously in 51 patients, retrograde arterially in 13, and by both routes in a further 6 patients. One 5 mm coil migrated but was successfully retrieved. Main outcome measures-In group A colour flow Doppler echocardiography showed that complete occlusion was achieved in 40/45 (89%) at 24 hours, 41/45 (91%) at 1 month, and 44/45 (98%) by 6 months post procedure. Occlusion rates in residual PDAs were 22/25 (88%) occluded at 24 hours, 23/25 (92%) at 1 month, and 24/25 (96%) at 6 months follow up. Conclusions-Transcatheter occlusion using detachable (Cook) spring coils is a safe and effective alternative to presently available devices. The delivery system allows full retrieval of the coil until a satisfactory position is obtained.
引用
收藏
页码:531 / 535
页数:5
相关论文
共 50 条
  • [21] Transvenous embolization of the patent ductus arteriosus with detachable coils in 2 cats
    Schneider, M
    Hildebrandt, N
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2003, 17 (03) : 349 - 353
  • [22] TRANSCATHETER COIL OCCLUSION OF PATENT DUCTUS-ARTERIOSUS
    FEDDERLY, RT
    LLOYD, TR
    MENDELSOHN, AM
    SANDHU, SK
    LUDOMIRSKY, A
    BEEKMAN, RH
    CIRCULATION, 1993, 88 (04) : 389 - 389
  • [23] Transcatheter occlusion of patent ductus arteriosus: State of the art
    Rao, PS
    Sideris, EB
    JOURNAL OF INVASIVE CARDIOLOGY, 1996, 8 (07): : 278 - 288
  • [24] TRANSCATHETER OCCLUSION OF PATENT DUCTUS-ARTERIOSUS IN ADULTS
    SCHENCK, MH
    OLAUGHLIN, MP
    ROKEY, R
    LUDOMIRSKY, A
    MULLINS, CE
    AMERICAN JOURNAL OF CARDIOLOGY, 1993, 72 (07): : 591 - 595
  • [25] Transcatheter occlusion of complex patent ductus arteriosus.
    Zhang, F.
    Ge, J.
    Zhou, D.
    Guan, L.
    AMERICAN JOURNAL OF CARDIOLOGY, 2006, 97 (8B): : 50D - 51D
  • [26] Transcatheter Patent Ductus Arteriosus Occlusion in Small Infants
    Schwartz, Matthew C.
    Nykanen, David
    Winner, Lawrence H.
    Perez, Jose
    McMahan, Michael
    Munro, Hamish M.
    Narasimhulu, Sukumar Suguna
    CONGENITAL HEART DISEASE, 2016, 11 (06) : 647 - 655
  • [27] Anterograde transcatheter occlusion of the patent ductus arteriosus with Gianturco coils - A new, effective and inexpensive technique
    DeMoor, M
    Lawrenson, J
    Fadley, FA
    Pribut, H
    Galal, O
    SOUTH AFRICAN MEDICAL JOURNAL, 1996, 86 : C143 - C146
  • [28] Transcatheter occlusion of patent ductus arteriosus with a new detachable coil system (DuctOcclud) - a multicenter clinical trial
    Oho, S
    Ishizawa, A
    Koike, K
    Kobayashi, T
    Nakanishi, T
    Momma, K
    Ino, T
    Nishimoto, K
    Ohkubo, M
    Ono, Y
    Kamiya, T
    Akagi, T
    Kato, H
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1998, 62 (07): : 489 - 493
  • [29] TRANSCATHETER OCCLUSION OF NATIVE END RESIDUAL PATENT DUCTUS-ARTERIOSUS WITH A NEW DETACHABLE COIL SYSTEM
    TOMETZKI, AJP
    WALSH, KP
    ARNOLD, RR
    PEART, I
    SREERAM, N
    ABDULHAMED, J
    GODMAN, MJ
    KITCHINER, DJ
    BULOCK, FA
    CIRCULATION, 1995, 92 (08) : 1477 - 1477
  • [30] Transcatheter occlusion of the arterial duct with Cook detachable coils: Early experience
    Uzun, O
    Hancock, S
    Parsons, JM
    Dickinson, DF
    Gibbs, JL
    HEART, 1996, 76 (03) : 269 - 273