Evaluation of a steady-state method to estimate indoor PM2.5 concentration of outdoor origin

被引:19
|
作者
Sun, Zhiwei [1 ,2 ]
Liu, Cong [3 ,4 ]
Zhang, Yinping [1 ,2 ]
机构
[1] Tsinghua Univ, Dept Bldg Sci, Beijing 100084, Peoples R China
[2] Beijing Key Lab Indoor Air Qual Evaluat & Control, Beijing 100084, Peoples R China
[3] Southeast Univ, Sch Energy & Environm, Nanjing 210096, Peoples R China
[4] Minist Educ, Engn Res Ctr Bldg Equipment Energy & Environm, Nanjing 210096, Jiangsu, Peoples R China
基金
美国国家科学基金会;
关键词
Indoor air quality; Exposure; PM2.5; Steady-state method; Infiltration factor (F-inf); PARTICULATE AIR-POLLUTION; WINDOW-OPENING BEHAVIOR; RESIDENTIAL BUILDINGS; INFILTRATION FACTOR; FINE PARTICLES; TERM EXPOSURE; MORTALITY; MATTER; VENTILATION; IMPACT;
D O I
10.1016/j.buildenv.2019.106243
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Exposure to PM2.5 of outdoor origin, which leads to millions of global premature deaths annually, occurs mainly indoors. A steady-state method has been used to estimate averaged indoor PM2.5 concentration of outdoor origin, but its relative error has not been clarified. This study addresses that problem by comparing the results of a steady-state method to those of a dynamic method. For the cases evaluated, the steady-state method can model indoor annual-, seasonal-, monthly-, and weekly-average PM2.5 concentration of outdoor origin with relative error less than 30%. The relative error of 95% of the daily-average concentrations by the steady-state method is less than 31%, while the maximum is 57%. Sensitivity analysis indicates that both pattern (determined by window opening/closing behavior) and strength of air exchange rate significantly impact the error. Therefore, the averaged concentration of a period longer than one week using the steady-state method can be used to estimate the corresponding health risk. The averaged concentration of a short time period (daily or hourly) has a large relative error and should not be used for estimating the corresponding heath risk or controlling the operation of the air cleaning systems.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Vertical distribution of PAHs in the indoor and outdoor PM2.5 in Guangzhou, China
    Li, CL
    Fu, JM
    Sheng, GY
    Bi, XH
    Hao, YM
    Wang, XM
    Mai, BX
    BUILDING AND ENVIRONMENT, 2005, 40 (03) : 329 - 341
  • [22] Tracer element for indoor PM2.5 in China migrated from outdoor
    Ji, Wenjing
    Li, Hongyu
    Zhao, Bin
    Deng, Furong
    ATMOSPHERIC ENVIRONMENT, 2018, 176 : 171 - 178
  • [23] Chemical composition of indoor and outdoor PM2.5 in the eastern Arabian Peninsula
    Tutsak, Ersin
    Alfoldy, Balint
    Mahfouz, Mohamed M.
    Al-Thani, Jassem A.
    Yigiterhan, Oguz
    Shahid, Imran
    Isaifan, Rima J.
    Koçak, Mustafa
    Environmental Science and Pollution Research, 2024, 31 (37) : 49589 - 49600
  • [24] Correlation Analysis of Indoor and Outdoor PM2.5 and Exploration of Prevention Methods
    Pan, Hui
    Wang, Hongyun
    Qian, Yong
    Tang, Yan
    2020 2ND INTERNATIONAL CONFERENCE ON CIVIL ENGINEERING, ENVIRONMENT RESOURCES AND ENERGY MATERIALS, 2021, 634
  • [25] Characterization and sources of indoor and outdoor microplastics and PM2.5: Possible relationships
    Zheng, Han
    Yao, Kaixing
    Guo, Huibin
    AIR QUALITY ATMOSPHERE AND HEALTH, 2025, 18 (03): : 645 - 656
  • [26] Spatial and temporal variability in outdoor, indoor, and personal PM2.5 exposure
    Adgate, JL
    Ramachandran, G
    Pratt, GC
    Waller, LA
    Sexton, K
    ATMOSPHERIC ENVIRONMENT, 2002, 36 (20) : 3255 - 3265
  • [27] Indoor-outdoor PM2.5 and PM10 in New York City
    Kendall, M
    Bonnano, L
    Wallace, L
    Lippman, M
    EPIDEMIOLOGY, 2002, 13 (04) : S85 - S86
  • [28] Indoor residential and outdoor sources of PM2.5 and PM10 in Nicosia, Cyprus
    Yichen Wang
    Petros Koutrakis
    Antonis Michanikou
    Panayiotis Kouis
    Andrie G. Panayiotou
    Paraskevi Kinni
    Filippos Tymvios
    Andreas Chrysanthou
    Marina Neophytou
    Petros Mouzourides
    Chrysanthos Savvides
    Emily Vasiliadou
    Ilias Papasavvas
    Theodoros Christophides
    Rozalia Nicolaou
    Panayiotis Avraamides
    Choong-Min Kang
    Stefania I. Papatheodorou
    Nicos Middleton
    Panayiotis K. Yiallouros
    Souzana Achilleos
    Air Quality, Atmosphere & Health, 2024, 17 : 485 - 499
  • [29] Indoor residential and outdoor sources of PM2.5 and PM10 in Nicosia, Cyprus
    Wang, Yichen
    Koutrakis, Petros
    Michanikou, Antonis
    Kouis, Panayiotis
    Panayiotou, Andrie G.
    Kinni, Paraskevi
    Tymvios, Filippos
    Chrysanthou, Andreas
    Neophytou, Marina
    Mouzourides, Petros
    Savvides, Chrysanthos
    Vasiliadou, Emily
    Papasavvas, Ilias
    Christophides, Theodoros
    Nicolaou, Rozalia
    Avraamides, Panayiotis
    Kang, Choong-Min
    Papatheodorou, Stefania I.
    Middleton, Nicos
    Yiallouros, Panayiotis K.
    Achilleos, Souzana
    AIR QUALITY ATMOSPHERE AND HEALTH, 2024, 17 (03): : 485 - 499
  • [30] Distribution Characteristics of Indoor PM2.5 Concentration Based on the Water Type and Humidification Method
    Park, Seonghyun
    Seo, Janghoo
    Lee, Sunwoo
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (22) : 1 - 15