Evaluation of a steady-state method to estimate indoor PM2.5 concentration of outdoor origin

被引:19
|
作者
Sun, Zhiwei [1 ,2 ]
Liu, Cong [3 ,4 ]
Zhang, Yinping [1 ,2 ]
机构
[1] Tsinghua Univ, Dept Bldg Sci, Beijing 100084, Peoples R China
[2] Beijing Key Lab Indoor Air Qual Evaluat & Control, Beijing 100084, Peoples R China
[3] Southeast Univ, Sch Energy & Environm, Nanjing 210096, Peoples R China
[4] Minist Educ, Engn Res Ctr Bldg Equipment Energy & Environm, Nanjing 210096, Jiangsu, Peoples R China
基金
美国国家科学基金会;
关键词
Indoor air quality; Exposure; PM2.5; Steady-state method; Infiltration factor (F-inf); PARTICULATE AIR-POLLUTION; WINDOW-OPENING BEHAVIOR; RESIDENTIAL BUILDINGS; INFILTRATION FACTOR; FINE PARTICLES; TERM EXPOSURE; MORTALITY; MATTER; VENTILATION; IMPACT;
D O I
10.1016/j.buildenv.2019.106243
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Exposure to PM2.5 of outdoor origin, which leads to millions of global premature deaths annually, occurs mainly indoors. A steady-state method has been used to estimate averaged indoor PM2.5 concentration of outdoor origin, but its relative error has not been clarified. This study addresses that problem by comparing the results of a steady-state method to those of a dynamic method. For the cases evaluated, the steady-state method can model indoor annual-, seasonal-, monthly-, and weekly-average PM2.5 concentration of outdoor origin with relative error less than 30%. The relative error of 95% of the daily-average concentrations by the steady-state method is less than 31%, while the maximum is 57%. Sensitivity analysis indicates that both pattern (determined by window opening/closing behavior) and strength of air exchange rate significantly impact the error. Therefore, the averaged concentration of a period longer than one week using the steady-state method can be used to estimate the corresponding health risk. The averaged concentration of a short time period (daily or hourly) has a large relative error and should not be used for estimating the corresponding heath risk or controlling the operation of the air cleaning systems.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Determinants of indoor and personal exposure to PM2.5 of indoor and outdoor origin during the RIOPA study
    Meng, Qing Yu
    Spector, Dalia
    Colome, Steven
    Turpin, Barbara
    ATMOSPHERIC ENVIRONMENT, 2009, 43 (36) : 5750 - 5758
  • [2] Indoor and outdoor concentration of PM2.5 vanadium, nickel, and sulphur in three Mediterrane areas
    Cibella, Fabio
    Perrino, Cinzia
    Balzan, Martin
    Ruggieri, Silvia
    Bilocca, David
    Drago, Gaspare
    Zammit, Christopher
    Minardi, Remo
    Cuttitta, Giuseppina
    Melis, Mario
    Montefort, Stephen
    Viegi, Giovanni
    EUROPEAN RESPIRATORY JOURNAL, 2014, 44
  • [3] Indoor and outdoor concentration of PM10, PM2.5 and PM1 in residential building and evaluation of negative air ions (NAIs) in indoor PM removal
    Nadali, Azam
    Arfaeinia, Hossein
    Asadgol, Zahra
    Fahiminia, Mohammad
    ENVIRONMENTAL POLLUTANTS AND BIOAVAILABILITY, 2020, 32 (01) : 47 - 55
  • [4] Indoor/outdoor PM10 and PM2.5 in Bangkok, Thailand
    FENG C TSAI
    KIRK R SMITH
    NUNTAVARN VICHIT-VADAKAN
    BART D OSTRO
    LAURAINE G CHESTNUT
    NIPAPUN KUNGSKULNITI
    Journal of Exposure Science & Environmental Epidemiology, 2000, 10 : 15 - 26
  • [5] Indoor/outdoor PM10 and PM2.5 in Bangkok, Thailand
    Tsai, FC
    Smith, KR
    Vichit-Vadakan, N
    Ostro, BD
    Chestnut, LG
    Kungskulniti, N
    JOURNAL OF EXPOSURE ANALYSIS AND ENVIRONMENTAL EPIDEMIOLOGY, 2000, 10 (01): : 15 - 26
  • [6] Relations between indoor and outdoor PM2.5 and constituent concentrations
    Cong Liu
    Yinping Zhang
    Frontiers of Environmental Science & Engineering, 2019, 13
  • [7] Personal exposure monitoring of PM2.5 in indoor and outdoor microenvironments
    Steinle, Susanne
    Reis, Stefan
    Sabel, Clive E.
    Semple, Sean
    Twigg, Marsailidh M.
    Braban, Christine F.
    Leeson, Sarah R.
    Heal, Mathew R.
    Harrison, David
    Lin, Chun
    Wu, Hao
    SCIENCE OF THE TOTAL ENVIRONMENT, 2015, 508 : 383 - 394
  • [8] The carbon components in indoor and outdoor PM2.5 in winter of Tianjin
    Wang, Baoqing
    Li, Yinuo
    Tang, Zhenzhen
    Cai, Ningning
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [9] Sources of indoor and outdoor PM2.5 concentrations in primary schools
    Amato, F.
    Rivas, I.
    Viana, M.
    Moreno, T.
    Bouso, L.
    Reche, C.
    Alvarez-Pedrerol, M.
    Alastuey, A.
    Sunyer, J.
    Querol, X.
    SCIENCE OF THE TOTAL ENVIRONMENT, 2014, 490 : 757 - 765
  • [10] Assessment of Reduction in Indoor PM2.5 of Outdoor Origin by using Nanofiber Filters as Window Screens
    Shi, Shanshan
    Chen, Chun
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 2386 - 2392