Theory and application of static field inhomogeneity effects in gradient-echo imaging

被引:232
|
作者
Reichenbach, JR
Venkatesan, R
Yablonskiy, DA
Thompson, MR
Lai, S
Haacke, EM
机构
[1] Mallinckrodt Institute of Radiology, Washington University, St. Louis, MO 63110
[2] Dept. of Biomed. and Biol. Eng., Washington University, St. Louis
[3] Department of Physics, Case Western Reserve University, Cleveland
[4] Lucas MRS Imaging Center, Stanford University, Stanford
来源
关键词
artifact; rapid imaging; phase imaging; K space; image processing; brain;
D O I
10.1002/jmri.1880070203
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The influence of local static magnetic field inhomogeneities on gradient-echo imaging is discussed and the underlying theoretical aspects are reviewed, A high-resolution approach is suggested to suppress image distortion and restore signal loss due to spin dephasing. Acquisition of three-dimensional data sets not only overcomes part of the limitations associated with gradient echoes but also makes it possible to extract local information about the strength or direction of background gradients and relative susceptibility changes between different tissues. Applications of the suggested approach in the human brain for anatomical imaging as well as for extraction of physical and physiological parameters are presented and discussed.
引用
收藏
页码:266 / 279
页数:14
相关论文
共 50 条
  • [21] VASCULAR INTRACRANIAL LESIONS - APPLICATIONS OF GRADIENT-ECHO MR IMAGING
    ATLAS, SW
    MARK, AS
    FRAM, EK
    GROSSMAN, RI
    RADIOLOGY, 1988, 169 (02) : 455 - 461
  • [22] A GUIDE TO UNDERSTANDING KEY ASPECTS OF FAST GRADIENT-ECHO IMAGING
    HAACKE, EM
    FRAHM, J
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1991, 1 (06): : 621 - 624
  • [23] Physiological noise compensation in gradient-echo myelin water imaging
    Nam, Yoonho
    Kim, Dong-Hyun
    Lee, Jongho
    NEUROIMAGE, 2015, 120 : 345 - 349
  • [24] Inflow effect correction in fast gradient-echo perfusion imaging
    Ivancevic, MK
    Zimine, I
    Montet, X
    Hyacinthe, JN
    Lazeyras, F
    Foxall, D
    Vallée, JP
    MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (05) : 885 - 891
  • [25] ON SELF-REFOCUSING PULSES FOR RAPID GRADIENT-ECHO IMAGING
    MCKINNON, GC
    MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (02) : 260 - 262
  • [26] Tissue temperature monitoring with multiple gradient-echo imaging sequences
    Mulkern, RV
    Panych, LP
    McDannold, NJ
    Jolesz, FA
    Hynynen, K
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (02): : 493 - 502
  • [27] On the artifact of a subvoxel susceptibility deviation in spoiled gradient-echo imaging
    Bos, C
    Viergever, MA
    Bakker, CJG
    MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (02) : 400 - 404
  • [28] Generalized equation for describing the magnetization in spoiled gradient-echo imaging
    Murase, Kenya
    MAGNETIC RESONANCE IMAGING, 2011, 29 (05) : 723 - 730
  • [29] AQUEDUCTAL STENOSIS - EVALUATION WITH GRADIENT-ECHO RAPID MR IMAGING
    ATLAS, SW
    MARK, AS
    FRAM, EK
    RADIOLOGY, 1988, 169 (02) : 449 - 453
  • [30] MRI APPEARANCES OF THE ASYMPTOMATIC PATELLAR TENDON ON GRADIENT-ECHO IMAGING
    REIFF, DB
    HEENAN, SD
    HERON, CW
    SKELETAL RADIOLOGY, 1995, 24 (02) : 123 - 126