Investigation and evaluation of building energy flexibility with energy storage system in hot summer and cold winter zones

被引:24
|
作者
Liu, Jiangyang [1 ]
Yang, Xu [3 ]
Liu, Zhongbing [1 ,2 ]
Zou, Juan [3 ]
Wu, Yaling [1 ]
Zhang, Ling [1 ,2 ]
Zhang, Yelin [1 ,4 ]
Xiao, Hui [5 ]
机构
[1] Hunan Univ, Coll Civil Engn, Changsha 410082, Peoples R China
[2] Hunan Univ, Key Lab Bldg Safety & Energy Efficiency, Minist Educ, Changsha 410082, Peoples R China
[3] Xiangtan Univ, Key Lab Intelligent Comp & Informat Proc, Minist Educ, Informat Engn Coll, Xiangtan, Hunan, Peoples R China
[4] City Univ Hong Kong, Dept Architecture & Civil Engn, Hong Kong, Peoples R China
[5] Changsha Univ Sci & Technol, Dept Elect Engn, Changsha, Peoples R China
关键词
Energy flexibility; Energy storage; Multi-objective optimization; Load coefficient; AIR-CONDITIONING SYSTEM; DEMAND RESPONSE; OPTIMIZATION; PERFORMANCE; MANAGEMENT; DESIGN;
D O I
10.1016/j.est.2021.103877
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The dramatically increasing energy demand of building air-conditioning in hot summer and cold winter zones fluctuates greatly, especially during the period of cooling and heating in summer and winter, which exerts strict operation burden and challenge on power-grid system stability. In order to realize building energy flexibility, this paper proposes a type of energy utilization system including electricity chiller, gas-boiler, electricity heater, cold and thermal energy storage tank (case II), on the basis of electricity chiller and gas-boiler for cooling and heating demand (case I), which is commonly used as cold and heat source in hot summer and cold winter zones. The total cost of the whole life period and annual carbon emission of energy systems are served as objective function is optimized. Furthermore, the system capacity confirmation and load demand management control are analyzed and discussed, the characteristics of energy-flexibility with and without energy storage are presented, the load coefficient is introduced to evaluate the impact of case II on building energy flexibility. Compared with case I, with the deployment of cold and thermal energy storage, the cost-effectiveness of case II is 16.5% and carbon emission is reduced by 30.9% compared with case I .In case II, the load coefficient of electricity chiller and electricity heater is 83.34% and 30.65% respectively, which means that energy storage system enables to promote building energy flexibility improvement and grid-friendliness enhancement. This paper provides methods and theoretical guidance for the planning-operation of building energy system and building energy flexibility in hot summer and cold winter zones.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Energy Sayings Potential for Buildings in Hot Summer and Cold Winter Zone
    Wang, Tianhong
    Yao, Jian
    ADVANCED RESEARCH ON COMPUTER EDUCATION, SIMULATION AND MODELING, PT II, 2011, 176 (02): : 434 - 437
  • [22] Evaluation on energy and thermal performance for residential envelopes in hot summer and cold winter zone of China
    Yu, Jinghua
    Yang, Changzhi
    Tian, Liwei
    Liao, Dan
    APPLIED ENERGY, 2009, 86 (10) : 1970 - 1985
  • [23] Performance simulation of underground seasonal thermal energy storage in hot summer and cold winter zone in China
    Li, Yong
    Li, Yong
    Chen, Xudong
    Ipposhi, Shigetoshi
    Nomura, Yasumitsu
    Wang, Ruzhu
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2020, 41 (09): : 382 - 388
  • [24] INFLUENCE AND ANALYSIS OF RESIDENTIAL BUILDING ORIENTATION ON BUILDING ENERGY CONSUMPTION AT HOT SUMMER AND COLD WINTER ZONE IN CHANGSHA, CHINA
    Dong, Q.
    Li, N. P.
    Wang, B. J.
    Yang, Y.
    Xiao, Z. H.
    Duan, J. J.
    Sha, Z.
    7TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, PROCEEDINGS OF ISHVAC 2011, VOLS I-IV, 2011, : 1136 - 1140
  • [25] Performance simulation of underground seasonal solar energy storage in hot summer and cold winter zone in china
    Li, Yong
    Chen, Xudong
    Ipposhi, Shigetoshi
    Nomura, Yasumitsu
    Wang, Ruzhu
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2019, 25 (07) : 925 - 934
  • [26] Building energy flexibility with battery energy storage system: a comprehensive review
    Xinhua Xu
    Yuting Fu
    Yongqiang Luo
    Discover Mechanical Engineering, 1 (1):
  • [27] Energy Retrofitting Assessment of Public Building Envelopes in China's Hot Summer and Cold Winter Climate Region
    Liu, Changchun
    Ma, Wenting
    Hao, Jianli
    Luo, Daiwei
    Zuo, Jian
    Zhang, Cheng
    BUILDINGS, 2022, 12 (11)
  • [28] Comprehensive assessment of building energy consumption in hot summer and cold winter areas based on carbon tax considerations
    Xie, Jing
    Miao, Xinyue
    Dewancker, Bart Julien
    Xu, Tongyu
    Zhao, Xueyuan
    Shi, Chunyan
    Wei, Xindong
    FRONTIERS IN ENERGY RESEARCH, 2023, 11
  • [29] Study on Thermal Behavior of an Experimental Low-energy Building in the Hot Summer and Cold Winter Zone of China
    Shi, Feng
    Yu, Zhuang
    JOURNAL OF ASIAN ARCHITECTURE AND BUILDING ENGINEERING, 2016, 15 (03) : 503 - 510
  • [30] Research on Climate Adaptability of Energy Conservation Building with Renewable Energy Sources in Hot-summer and Cold-winter Zone of China
    Hui Zhang
    Zhuang Yu
    RENEWABLE ENERGY AND ENVIRONMENTAL TECHNOLOGY, PTS 1-6, 2014, 448-453 : 1289 - 1296