Minimising flow losses within the pulse tube of a Stirling pulse tube cryocooler

被引:1
|
作者
Abolghasemi, M. A. [1 ]
Stone, R. [1 ]
Dadd, M. [1 ]
Bailey, P. [1 ]
Liang, K. [2 ]
机构
[1] Univ Oxford, Dept Engn Sci, Oxford, England
[2] Univ Sussex, Dept Engn & Design, Brighton, E Sussex, England
基金
英国工程与自然科学研究理事会;
关键词
INERTANCE;
D O I
10.1088/1757-899X/502/1/012044
中图分类号
O59 [应用物理学];
学科分类号
摘要
Successful operation of Stirling pulse tube cryocoolers relies on minimising flow mixing within the pulse tube. Hence, the pulse tube and the flow straighteners at either end must be designed with great care. In this study, the flow within the pulse tube of an existing Stirling pulse tube cryocooler is numerically analysed and alternative flow straightener designs are suggested. The numerical simulation have been carried out using CONVERGE CFD, a finite volume Navier-Stokes solver. The standar k-epsilon RANS turbulence model has been used to account for the effects of turbulence within the pulse tube.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Progress of pulse tube cryocooler
    Matsubara, Yoichi
    Koh, Deuk-Yong
    Journal of the Korea Institute of Applied Superconductivity and Cryogenics, 2010, 12 (04): : 1 - 7
  • [22] A NOVEL STIRLING TYPE PULSE TUBE CRYOCOOLER SUPPRESSING THE THIRD TYPE OF DC GAS FLOW
    Gu, Chao
    Jin, Hai
    Zhou, Yuan
    Zhu, Wenxiu
    Wang, Junjie
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS 57A AND 57B, 2012, 1434 : 214 - 220
  • [23] The third type DC flow in pulse tube cryocooler
    Zhou Yuan
    Gu Chao
    Cai HuiKun
    SCIENCE IN CHINA SERIES E-TECHNOLOGICAL SCIENCES, 2009, 52 (12): : 3491 - 3496
  • [24] The third type DC flow in pulse tube cryocooler
    ZHOU Yuan1
    2Graduate University of Chinese Academy of Sciences
    Science in China(Series E:Technological Sciences), 2009, (12) : 3491 - 3496
  • [26] The third type DC flow in pulse tube cryocooler
    Yuan Zhou
    Chao Gu
    HuiKun Cai
    Science in China Series E: Technological Sciences, 2009, 52 : 3491 - 3496
  • [27] Loss Analysis of High Power Stirling-Type Pulse Tube Cryocooler
    Nakano, K.
    Hiratsuka, Y.
    ADVANCES IN CRYOGENIC ENGINEERING, 2015, 101
  • [28] An inter-phasing Stirling pulse-tube cryocooler without reservoirs
    Hu, J.
    Zhang, L.
    Wang, X.
    Zhu, J.
    Chen, S.
    Li, H.
    Dai, W.
    Luo, E.
    PROCEEDINGS OF THE 25TH INTERNATIONAL CRYOGENIC ENGINEERING CONFERENCE AND INTERNATIONAL CRYOGENIC MATERIALS CONFERENCE 2014, 2015, 67 : 509 - 512
  • [29] Development of a 1 to 5 W at 80 K stirling pulse tube cryocooler
    Hiratsuka, Y
    Kang, YM
    Matsubara, Y
    CRYOCOOLERS 10, 1999, : 149 - 155
  • [30] CFD simulation of the gas flow in a pulse tube cryocooler with two pulse tubes
    Yin, C. L.