Evaluation of the multi-element capabilities of collision/reaction cell inductively coupled plasma-mass spectrometry in wine analysis

被引:18
|
作者
Grindlay, Guillermo [1 ,2 ]
Mora, Juan [1 ]
de Loos-Vollebregt, Margaretha T. C. [2 ,3 ]
Vanhaecke, Frank [1 ]
机构
[1] Univ Alicante, Dept Analyt Chem Nutr & Food Sci, E-03080 Alicante, Spain
[2] Univ Ghent, Dept Analyt Chem, B-9000 Ghent, Belgium
[3] Delft Univ Technol, Fac Appl Sci Analyt Biotechnol, NL-2628 BC Delft, Netherlands
关键词
Spectral interference; Collision/reaction cell; ICP-MS; Multi-element analysis; Wine; ICP-MS; TRACE-ELEMENTS; METALS; INTERFERENCES; SYSTEM;
D O I
10.1016/j.talanta.2014.05.008
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work explores the multi-element capabilities of inductively coupled plasma-mass spectrometry with collision/reaction cell technology (CCT-ICP-MS) for the simultaneous determination of both spectrally interfered and non-interfered nuclides in wine samples using a single set of experimental conditions. The influence of the cell gas type (i.e. He, He+H-2 and He+NH3), cell gas flow rate and sample pre-treatment (i.e. water dilution or acid digestion) on the background-equivalent concentration (BEC) of several nuclides covering the mass range from 7 to 238 u has been studied. Results obtained in this work show that, operating the collision/reaction cell with a compromise cell gas flow rate (i.e. 4 mL min(-1)) improves BEC values for interfered nuclides without a significant effect on the BECs for non-interfered nuclides, with the exception of the light elements Li and Be. Among the different cell gas mixtures tested, the use of He or He+H-2 is preferred over He+NH3 because NH3 generates new spectral interferences. No significant influence of the sample pre-treatment methodology (i.e. dilution or digestion) on the multi-element capabilities of CCT-ICP-MS in the context of simultaneous analysis of interfered and non-interfered nuclides was observed. Nonetheless, sample dilution should be kept at minimum to ensure that light nuclides could be quantified in wine. Finally, a direct 5-fold aqueous dilution is recommended for the simultaneous trace and ultra-trace determination of spectrally interfered and non-interfered elements in wine by means of CCT-ICP-MS. The use of the CCT is mandatory for interference-free ultra-trace determination of Ti and Cr. Only Be could not be determined when using the CCT due to a deteriorated limit of detection when compared to conventional ICP-MS. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:379 / 385
页数:7
相关论文
共 50 条
  • [22] Multielemental Analysis of Biodiesel by Dynamic Reaction Cell-Inductively Coupled Plasma-Mass Spectrometry
    Ling, Zhao-Xing
    He, Yang-Ming
    Wang, Ping-Ya
    Zhou, Ying
    Ahmad, Farooq
    Zhao, Fang-Fang
    ANALYTICAL LETTERS, 2016, 49 (15) : 2461 - 2473
  • [23] Inductively coupled plasma mass spectrometry for direct multi-element analysis of diluted human blood and serum
    Barany, E
    Bergdahl, IA
    Schutz, A
    Skerfving, S
    Oskarsson, A
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (09) : 1005 - 1009
  • [24] Rapid multi-element analysis of Chinese vinegar by sector field inductively coupled plasma mass spectrometry
    Liang Fu
    Xi-du Nie
    Hua-Lin Xie
    Miguel Duarte Ferro
    European Food Research and Technology, 2013, 237 : 795 - 800
  • [25] Rapid multi-element analysis of groundwater by high-resolution inductively coupled plasma mass spectrometry
    Cheng, Z
    Zheng, Y
    Mortlock, R
    van Geen, A
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 379 (03) : 512 - 518
  • [26] Rapid multi-element analysis of groundwater by high-resolution inductively coupled plasma mass spectrometry
    Z. Cheng
    Y. Zheng
    R. Mortlock
    A. van Geen
    Analytical and Bioanalytical Chemistry, 2004, 379 : 512 - 518
  • [27] Rapid multi-element analysis of Chinese vinegar by sector field inductively coupled plasma mass spectrometry
    Fu, Liang
    Nie, Xi-du
    Xie, Hua-Lin
    Ferro, Miguel Duarte
    EUROPEAN FOOD RESEARCH AND TECHNOLOGY, 2013, 237 (05) : 795 - 800
  • [28] Application of extraction induced by emulsion breaking for trace multi-element determination in jet fuel by inductively coupled plasma-mass spectrometry
    He, Yang-Ming
    Ling, Zhao-Xing
    Zhou, Ying
    Ahmad, Farooq
    Zhao, Fang-Fang
    SPECTROSCOPY LETTERS, 2016, 49 (01) : 37 - 43
  • [29] Development of column-pretreatment chelating resins for matrix elimination/multi-element determination by inductively coupled plasma-mass spectrometry
    Gao, YH
    Oshita, K
    Lee, KH
    Oshima, M
    Motomizu, S
    ANALYST, 2002, 127 (12) : 1713 - 1719
  • [30] Determination of Metals Content in Wine Samples by Inductively Coupled Plasma-Mass Spectrometry
    Plotka-Wasylka, Justyna
    Frankowski, Marcin
    Simeonov, Vasil
    Polkowska, Zaneta
    Namiesnik, Jacek
    MOLECULES, 2018, 23 (11):