Evaluation of the multi-element capabilities of collision/reaction cell inductively coupled plasma-mass spectrometry in wine analysis

被引:18
|
作者
Grindlay, Guillermo [1 ,2 ]
Mora, Juan [1 ]
de Loos-Vollebregt, Margaretha T. C. [2 ,3 ]
Vanhaecke, Frank [1 ]
机构
[1] Univ Alicante, Dept Analyt Chem Nutr & Food Sci, E-03080 Alicante, Spain
[2] Univ Ghent, Dept Analyt Chem, B-9000 Ghent, Belgium
[3] Delft Univ Technol, Fac Appl Sci Analyt Biotechnol, NL-2628 BC Delft, Netherlands
关键词
Spectral interference; Collision/reaction cell; ICP-MS; Multi-element analysis; Wine; ICP-MS; TRACE-ELEMENTS; METALS; INTERFERENCES; SYSTEM;
D O I
10.1016/j.talanta.2014.05.008
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work explores the multi-element capabilities of inductively coupled plasma-mass spectrometry with collision/reaction cell technology (CCT-ICP-MS) for the simultaneous determination of both spectrally interfered and non-interfered nuclides in wine samples using a single set of experimental conditions. The influence of the cell gas type (i.e. He, He+H-2 and He+NH3), cell gas flow rate and sample pre-treatment (i.e. water dilution or acid digestion) on the background-equivalent concentration (BEC) of several nuclides covering the mass range from 7 to 238 u has been studied. Results obtained in this work show that, operating the collision/reaction cell with a compromise cell gas flow rate (i.e. 4 mL min(-1)) improves BEC values for interfered nuclides without a significant effect on the BECs for non-interfered nuclides, with the exception of the light elements Li and Be. Among the different cell gas mixtures tested, the use of He or He+H-2 is preferred over He+NH3 because NH3 generates new spectral interferences. No significant influence of the sample pre-treatment methodology (i.e. dilution or digestion) on the multi-element capabilities of CCT-ICP-MS in the context of simultaneous analysis of interfered and non-interfered nuclides was observed. Nonetheless, sample dilution should be kept at minimum to ensure that light nuclides could be quantified in wine. Finally, a direct 5-fold aqueous dilution is recommended for the simultaneous trace and ultra-trace determination of spectrally interfered and non-interfered elements in wine by means of CCT-ICP-MS. The use of the CCT is mandatory for interference-free ultra-trace determination of Ti and Cr. Only Be could not be determined when using the CCT due to a deteriorated limit of detection when compared to conventional ICP-MS. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:379 / 385
页数:7
相关论文
共 50 条
  • [1] Rapid Multi-Element Analysis of Red Wine by Inductively Coupled Plasma Tandem Mass Spectrometry
    Zhang, Ping
    Liu, Hongwei
    Shipin Kexue/Food Science, 2019, 40 (02): : 259 - 263
  • [2] Multivariate analysis to discriminate the origin of sesame seeds by multi-element analysis inductively coupled plasma-mass spectrometry
    Young Hee Choi
    Chae Kyu Hong
    Misun Kim
    Sun Oak Jung
    Juseong Park
    Young Hee Oh
    Joong-Ho Kwon
    Food Science and Biotechnology, 2017, 26 : 375 - 379
  • [3] Multivariate analysis to discriminate the origin of sesame seeds by multi-element analysis inductively coupled plasma-mass spectrometry
    Choi, Young Hee
    Hong, Chae Kyu
    Kim, Misun
    Jung, Sun Oak
    Park, Juseong
    Oh, Young Hee
    Kwon, Joong-Ho
    FOOD SCIENCE AND BIOTECHNOLOGY, 2017, 26 (02) : 375 - 379
  • [4] New application of microwave digestion-inductively coupled plasma-mass spectrometry for multi-element analysis in komatiites
    Nna-Mvondo, Delphine
    Martin-Redondo, Maria-Paz
    Martinez-Frias, Jesus
    ANALYTICA CHIMICA ACTA, 2008, 628 (02) : 133 - 142
  • [5] Multi-element determination in complex matrices by inductively coupled plasma-mass spectrometry (ICP-MS)
    Holmes, LJ
    Robinson, VJ
    Makinson, PR
    Livens, FR
    SCIENCE OF THE TOTAL ENVIRONMENT, 1995, 173 (1-6) : 345 - 350
  • [7] ASSESSMENT OF THE ANALYTICAL CAPABILITIES OF INDUCTIVELY COUPLED PLASMA-MASS SPECTROMETRY
    TAYLOR, HE
    GARBARINO, JR
    JOURNAL OF RESEARCH OF THE NATIONAL BUREAU OF STANDARDS, 1988, 93 (03): : 433 - 435
  • [8] Multi-element Analysis of Ferromanganese Nodules and Crusts by Inductively Coupled Plasma Mass Spectrometry
    Wang, Xiaoyuan
    Yin, Xuebo
    Zeng, Zhigang
    Chen, Shuai
    ATOMIC SPECTROSCOPY, 2019, 40 (05) : 153 - 160
  • [9] Multi-element analysis in plastics by laser ablation inductively coupled plasma mass spectrometry
    Kayar, Murat
    Izgi, Belgin
    Cimenoglu, M. Akif
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2016, 399 : 10 - 16
  • [10] Attenuation of interference in collision/reaction cell inductively coupled plasma mass spectrometry, using helium and hydrogen as cell gases - application to multi-element analysis of mastic gum
    Rousis, Nikolaos I.
    Pasias, Loannis N.
    Thomaidis, Nikotaos S.
    ANALYTICAL METHODS, 2014, 6 (15) : 5899 - 5908