Optimal Design of Tuned Liquid Column Damper for Wind-induced Response Control of Benchmark Tall Building

被引:10
|
作者
Suthar, Sameer J. [1 ]
Jangid, Radhey Shyam [1 ]
机构
[1] Indian Inst Technol, Dept Civil Engn, Mumbai 400076, Maharashtra, India
关键词
Tuned liquid column damper; Mass dampers; Tall buildings; Across-wind response; Nonlinear optimization; Wind loads; SEISMIC VIBRATION CONTROL; PERFORMANCE EVALUATION; HIGHRISE BUILDINGS; HYBRID CONTROL; MASS DAMPERS; BALL DAMPER; OPTIMIZATION; SINGLE; MOTION; TLCD;
D O I
10.1007/s42417-022-00528-6
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Method In this study, control effectiveness of optimal tuned liquid column damper (TLCD) on acrosswind response control of 76 story wind-excited benchmark tall building is investigated. The optimal design of TLCD was carried out using nonlinear constraint optimization technique. The absolute value of top floor peak acceleration was used as objective function and constraints were placed on the liquid column displacement and tuning frequency of vibration of the TLCD. Results The structural response of benchmark tall building with and without optimal TLCD is compared. It is found that the optimal TLCD effectively control the structural response of thebuilding. Beat phenomenon is also observed in liquid displacement as well as structural response time histories. To investigate the effect of off-tuning due to change in the stiffness of the building, uncertainties in the stiffness were considered and the performance of optimal TLCD was investigated. Conclusion It is found that the optimal TLCD is robust against acceleration control, but needs improvement against displacement control.
引用
收藏
页码:2935 / 2945
页数:11
相关论文
共 50 条
  • [21] Tuned Liquid Column Damper Inerter (TLCDI) for Wind-Induced Vibration Control of Fixed-Base Structures
    Chiara, Masnata
    Di Matteo, Alberto
    Adam, Christoph
    Pirrotta, Antonina
    PERSPECTIVES IN DYNAMICAL SYSTEMS I-APPLICATIONS, DSTA 2021, 2024, 453 : 351 - 368
  • [22] Real-world installations of tuned liquid column dampers for wind-induced vibration control of tall buildings
    Konar, Tanmoy
    Ghosh, Aparna Dey
    Basu, Biswajit
    STRUCTURE AND INFRASTRUCTURE ENGINEERING, 2024,
  • [23] Wind response control of tall buildings with a tuned mass damper
    Elias, Said
    Matsagar, Vasant
    JOURNAL OF BUILDING ENGINEERING, 2018, 15 : 51 - 60
  • [24] Experimental parametric study on wind-induced vibration control of particle tuned mass damper on a benchmark high-rise building
    Lu, Zheng
    Wang, Dianchao
    Zhou, Ying
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2017, 26 (08):
  • [25] Design of tuned liquid sloshing dampers using nonlinear constraint optimization for across-wind response control of benchmark tall building
    Suthar, Sameer J.
    Jangid, Radhey Shyam
    STRUCTURES, 2021, 33 : 2675 - 2688
  • [26] Nonlinear vibration control of a tall structure with tuned liquid column damper
    Lin, Shueei-Muh
    MECHANICS OF ADVANCED MATERIALS AND STRUCTURES, 2016, 23 (02) : 146 - 155
  • [27] VIBRATION CONTROL OF SUPER TALL BUILDINGS BY TUNED LIQUID COLUMN DAMPER
    Farshidianfar, Anooshirvan
    Oliazadeh, Pouria
    PROCEEDINGS OF THE 17TH INTERNATIONAL CONGRESS ON SOUND AND VIBRATION, 2010,
  • [28] Bioinspired Tuned Mass Damper for Mitigation of Wind-Induced Building Excitation
    Kwon, Isaac Y.
    Yang, Henry T.
    Hansma, Paul K.
    Randall, Connor J.
    JOURNAL OF STRUCTURAL ENGINEERING, 2017, 143 (10)
  • [29] Effect of building shape on wind-induced response of tall building
    Kwok, K.C.S.
    Journal of Wind Engineering and Industrial Aerodynamics, 1988, 28 pt 1 (1-3) : 381 - 390