Optimal Design of Tuned Liquid Column Damper for Wind-induced Response Control of Benchmark Tall Building

被引:10
|
作者
Suthar, Sameer J. [1 ]
Jangid, Radhey Shyam [1 ]
机构
[1] Indian Inst Technol, Dept Civil Engn, Mumbai 400076, Maharashtra, India
关键词
Tuned liquid column damper; Mass dampers; Tall buildings; Across-wind response; Nonlinear optimization; Wind loads; SEISMIC VIBRATION CONTROL; PERFORMANCE EVALUATION; HIGHRISE BUILDINGS; HYBRID CONTROL; MASS DAMPERS; BALL DAMPER; OPTIMIZATION; SINGLE; MOTION; TLCD;
D O I
10.1007/s42417-022-00528-6
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Method In this study, control effectiveness of optimal tuned liquid column damper (TLCD) on acrosswind response control of 76 story wind-excited benchmark tall building is investigated. The optimal design of TLCD was carried out using nonlinear constraint optimization technique. The absolute value of top floor peak acceleration was used as objective function and constraints were placed on the liquid column displacement and tuning frequency of vibration of the TLCD. Results The structural response of benchmark tall building with and without optimal TLCD is compared. It is found that the optimal TLCD effectively control the structural response of thebuilding. Beat phenomenon is also observed in liquid displacement as well as structural response time histories. To investigate the effect of off-tuning due to change in the stiffness of the building, uncertainties in the stiffness were considered and the performance of optimal TLCD was investigated. Conclusion It is found that the optimal TLCD is robust against acceleration control, but needs improvement against displacement control.
引用
收藏
页码:2935 / 2945
页数:11
相关论文
共 50 条
  • [1] Optimal Design of Tuned Liquid Column Damper for Wind-induced Response Control of Benchmark Tall Building
    Sameer J Suthar
    Radhey Shyam Jangid
    Journal of Vibration Engineering & Technologies, 2022, 10 : 2935 - 2945
  • [2] SUPPRESSION OF WIND-INDUCED VIBRATION OF A TALL BUILDING USING TUNED LIQUID DAMPER
    WAKAHARA, T
    OHYAMA, T
    FUJII, K
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1992, 43 (1-3) : 1895 - 1906
  • [3] Design of Tuned Mass Damper Fluid Inerter for Wind-Induced Vibration Control of a Tall Building
    Sarkar, Saptarshi
    Fitzgerald, Breiffni
    JOURNAL OF STRUCTURAL ENGINEERING, 2024, 150 (03)
  • [4] A combined tuned damper and an optimal design method for wind-induced vibration control for super tall buildings
    Wang, Lilin
    Zhao, Xin
    Zheng, Yimin M.
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2016, 25 (10): : 468 - 502
  • [5] Optimal design of a simplified tuned tandem mass damper for wind-induced vibration control of tall buildings
    Huang, Peng
    Tang, Yi
    Wang, Qinhua
    Qiao, Haoshuai
    STRUCTURES, 2025, 71
  • [6] Effect of tuned mass damper in wind-induced response of "V" plan-shaped tall building
    Bhattacharya, Satadru
    Dalui, Sujit Kumar
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2022, 31 (09):
  • [7] Evaluation on Aerodynamic Across-wind Response for a Tall Building Using Tuned Liquid Column Damper
    You, Jang-Youl
    You, Ki-Pyo
    Kim, Young-Moon
    ADVANCED CONSTRUCTION TECHNOLOGIES, 2014, 919-921 : 1361 - +
  • [8] Wind-induced torsional vibration control effect of bridge with magnetorheological tuned liquid column damper
    Sun, Hong-Xin
    Wang, Xiu-Yong
    Chen, Zheng-Qing
    Li, Chun-Guang
    Zhongguo Gonglu Xuebao/China Journal of Highway and Transport, 2010, 23 (01): : 58 - 65
  • [9] Wind-induced excitation control of a tall building with tuned mass dampers
    Kim, Young-Moon
    You, Ki-Pyo
    Kim, Han-Young
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2008, 17 (03): : 669 - 682
  • [10] CONTROL OF WIND-INDUCED TALL BUILDING VIBRATION BY TUNED MASS DAMPERS
    XU, YL
    KWOK, KCS
    SAMALI, B
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1992, 40 (01) : 1 - 32