Transmural Myocardial Strain in Mouse: Quantification of High-Resolution MR Tagging Using Harmonic Phase (HARP) Analysis

被引:11
|
作者
Zhong, Jia [1 ,2 ]
Liu, Wei [3 ,4 ]
Yu, Xin [1 ,2 ,3 ,4 ]
机构
[1] Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44122 USA
[2] Case Western Reserve Univ, Case Ctr Imaging Res, Cleveland, OH 44122 USA
[3] Washington Univ, Dept Med, Div Cardiovasc, Cardiovasc MR Labs, St Louis, MO USA
[4] Washington Univ, Dept Biomed Engn, St Louis, MO USA
关键词
MR tagging; transmural myocardial wall motion; SPAMM; HARP; mouse; CONTRACTILE DYSFUNCTION; VENTRICULAR TORSION; SPATIAL MODULATION; WALL MOTION; TAGGED MRI; HEART; MICE; INFARCTION; MAGNETIZATION; RESERVE;
D O I
10.1002/mrm.21942
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
MR tagging allows noninvasive examination of regional myocardial function with high accuracy and reproducibility. The current tagging method is limited by low tagging resolution for accurate transmural strain quantification. Previously, a spatial modulation of magnetization (SPAMM)-based method was proposed to increase the tagging resolution by combining two or more tagged images with different tagging grid positions. However, there has been limited application due to the challenge in image processing of multiple data sets. In the current study, we propose a harmonic phase (HARP)-based method for automated and fast analysis of high tagging resolution images. First-order harmonic peaks from low tagging resolution images were combined to generate the composite second-order harmonic peak for strain computation. The combined images reached a tagging resolution of 0.3 mm. The proposed method was applied to the quantification of transmural myocardial wall strain in seven normal C5713L/6 mice. Principal strains, as well as radial and circumferential strains, were quantified using the current method. Magn Reson Med 61:1368-1373, 2009. (C) 2009 Wiley-Liss, Inc.
引用
收藏
页码:1368 / 1373
页数:6
相关论文
共 50 条
  • [21] EVALUATION OF MYOCARDIAL STRAIN USING BANDPASS OPTICAL FLOW. COMPARISON TO HARMONIC PHASE ANALYSIS
    Hassanein, Azza S.
    Khalifa, Ayman M.
    Ibrahim, El-Sayed
    2015 IEEE 12th International Symposium on Biomedical Imaging (ISBI), 2015, : 1316 - 1319
  • [22] Longitudinal assessment of mouse renal injury using high-resolution anatomic and magnetization transfer MR imaging
    Wang, Feng
    Jiang, Rosie
    Takahashi, Keiko
    Gore, John
    Harris, Raymond C.
    Takahashi, Takamune
    Quarles, C. Chad
    MAGNETIC RESONANCE IMAGING, 2014, 32 (09) : 1125 - 1132
  • [23] High-resolution MR imaging of mouse brain microvasculature using the relaxation rate shift index Q
    Wu, EX
    Tang, HY
    Jensen, JH
    NMR IN BIOMEDICINE, 2004, 17 (07) : 507 - 512
  • [24] Quantification of Myocardial Perfusion Defect in Rats with Ultra-high Resolution SPECT System using QPS Software: Comparison with High-resolution Autoradiography
    Wakabayashi, H.
    Taki, J.
    Inaki, A.
    Hiromasa, T.
    Shiba, K.
    Kinuya, S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 : S566 - S566
  • [25] Noninvasive analysis of myocardial function using high-resolution Doppler tissue echocardiography in rats
    Shimizu, N
    Konstantinov, IE
    Suess, AM
    Cheung, M
    McCrindle, BW
    Vogel, M
    Redington, AN
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2005, 18 (05) : 461 - 467
  • [26] Non-invasive quantification of myocardial fibrosis in diabetic mice using in-vivo high-resolution MRI
    Sok Sithikun
    Frank Kober
    Alexis Jacquier
    Jérôme Kalifa
    Francis Kopp
    Marie-France Bonzi
    Jean-Claude Deharo
    Patrick J Cozzone
    Monique Bernard
    Journal of Cardiovascular Magnetic Resonance, 11 (Suppl 1)
  • [27] Direct Detection and Quantification of Methylation in Nucleic Acid Sequences Using High-Resolution Melting Analysis
    Lopez, Carlos M. Rodriguez
    Asenjo, Beatriz Guzman
    Lloyd, Amanda J.
    Wilkinson, Mike J.
    ANALYTICAL CHEMISTRY, 2010, 82 (21) : 9100 - 9108
  • [28] Challenges in Evaluating Thickness, Phase, and Strain in Semiconductor Devices Using High-Resolution Transmission Electron Microscopy
    Rai, Raghaw
    Conner, James
    Murphy, Sharon
    Subramanian, Swaminathan
    ISTFA 2006, 2006, : 343 - 350
  • [29] Comparison of Intravascular and Extracellular Contrast Media for Absolute Quantification of Myocardial Rest-Perfusion Using High-Resolution MRI
    Ritter, Christian O.
    Wilke, Aline
    Wichmann, Tobias
    Beer, Meinrad
    Hahn, Dietbert
    Koestler, Herbert
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 33 (05) : 1047 - 1051