Optimization of selective pressurized liquid extraction and ultrasonication-assisted QuEChERS methods for the determination of polybrominated diphenyl ethers in sediments

被引:11
|
作者
Song, Shanjun [1 ]
Dai, Xinhua [1 ]
Wang, Weihua [1 ]
He, Yajuan [1 ]
Liu, Zhao [1 ]
Shao, Mingwu [1 ]
机构
[1] Natl Inst Metrol, Beijing, Peoples R China
关键词
SOLID-PHASE EXTRACTION; TANDEM MASS-SPECTROMETRY; BROMINATED FLAME RETARDANTS; POLYCYCLIC AROMATIC-HYDROCARBONS; GAS-CHROMATOGRAPHY; SOUTH CHINA; POLYCHLORINATED-BIPHENYLS; ENVIRONMENTAL MATRICES; HYDROXYLATED ANALOGS; SPATIAL-DISTRIBUTION;
D O I
10.1039/c5ay02099a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two fast analytical methods, selective pressurized liquid extraction (SPLE) and ultrasonication-assisted QuEChERS methods (Quick, Easy, Cheap, Effective, Rugged and Safe) followed by GC-MS/MS, were optimized for the determination of polybrominated diphenyl ethers (PBDEs) in sediments. Ultrasonication was used to improve the extraction efficiency of QuEChERS. The experimental parameters of SPLE and ultrasonication-assisted QuEChERS, such as sorbent type, composition and elution solvents, were optimized in detail. The obtained recoveries of both methods were satisfactory for PBDE analysis. The inter/intra-day RSDs were <7%. The limits of quantification (LOQ) were <= 0.1 ng g(-1) dry weight (d.w.). The figures of merit were at the same level as former reported results. The proposed methods were validated for the analysis of PBDEs in standard reference materials (SRM 1944 and 2585). The results indicated that both optimized methods were feasible for the analysis and monitoring of PBDEs. Besides, the comparison between two methods revealed that elevated temperature and pressure could weaken the interaction between PBDEs and sediment matrices, resulting in improvement of extraction efficiency. Both proposed methods were successfully applied to the analysis of 3 sediment samples and the determination of BDE 47, 99, 100 and 153 suggested that both methods are practical and suitable for PBDE analysis in real sediment samples.
引用
收藏
页码:9542 / 9548
页数:7
相关论文
共 50 条
  • [41] Micro-solid phase extraction followed by thermal extraction coupled with gas chromatography-mass selective detector for the determination of polybrominated diphenyl ethers in water
    Naing, Nyi Nyi
    Li, Sam Fong Yau
    Lee, Hian Kee
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1458 : 25 - 34
  • [42] Design of experiment approach for the optimization of polybrominated diphenyl ethers determination in fine airborne particulate matter by microwave-assisted extraction and gas chromatography coupled to tandem mass spectrometry
    Beser, Maria Isabel
    Beltran, Joaquim
    Yusa, Vicent
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1323 : 1 - 10
  • [43] Determination of decabromodiphenyl ether in sediments using selective pressurized liquid extraction followed by GC–NCI-MS
    Ethel Eljarrat
    Agustina de la Cal
    Damià Barceló
    Analytical and Bioanalytical Chemistry, 2004, 378 : 610 - 614
  • [44] Determination of decabromodiphenyl ether in sediments using selective pressurized liquid extraction followed by GC-NCI-MS
    Eljarrat, E
    de la Cal, A
    Barceló, D
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 378 (03) : 610 - 614
  • [45] Determination of polybrominated diphenyl ethers in water and soil samples by cloud point extraction-ultrasound-assisted back-extraction-gas chromatography-mass spectrometry
    Fontana, Ariel R.
    Silva, Maria F.
    Martinez, Luis D.
    Wuilloud, Rodolfo G.
    Altamirano, Jorgelina C.
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (20) : 4339 - 4346
  • [46] Polybrominated diphenyl ethers (PBDEs) contents in house and car dust of Portugal by pressurized liquid extraction (PLE) and gas chromatography-mass spectrometry (GC-MS)
    Cunha, S. C.
    Kalachova, K.
    Pulkrabova, J.
    Fernandes, J. O.
    Oliveira, M. B. P. P.
    Alves, A.
    Hajslova, J.
    CHEMOSPHERE, 2010, 78 (10) : 1263 - 1271
  • [47] Determination of polybrominated diphenyl ethers in pine needles using ultrasonic-assisted extraction and gas chromatography negative chemical ionization-mass spectrometry
    Chen Chang'er
    Zhao Hongxia
    Xie Qing
    Chen Jingwen
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2009, 27 (01) : 59 - 62
  • [48] Determination of polybrominated diphenyl ethers in indoor dust using ultrasonic-assisted extraction and gas chromatography-negative chemical ionization mass spectrometry
    Zhang Xiaoling
    Wang Bingling
    Lu Xiaomei
    Zhang Qi
    Zhang Zhengdong
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2012, 30 (12) : 1241 - 1245
  • [49] Dispersive solid-phase extraction combined with dispersive liquid-liquid microextraction for the determination of polybrominated diphenyl ethers in plastic bottled beverage by GC-MS
    Han, Yi
    Jia, Xiaoyu
    Liu, Xinli
    Duan, Taicheng
    Chen, Hangting
    JOURNAL OF SEPARATION SCIENCE, 2011, 34 (09) : 1047 - 1054
  • [50] Extraction and determination of polybrominated diphenyl ethers in water and urine samples using solidified floating organic drop microextraction along with high performance liquid chromatography
    Liu, Huanqiang
    Zhang, Minghua
    Wang, Xuedong
    Zou, Yujie
    Wang, Wenwei
    Ma, Meiping
    Li, Yanyan
    Wang, Huili
    MICROCHIMICA ACTA, 2012, 176 (3-4) : 303 - 309