High-throughput assay of oxygen radical absorbance capacity (ORAC) using a multichannel liquid handling system coupled with a microplate flourescence reader in 96-well format

被引:1228
|
作者
Huang, DJ
Ou, BX
Hampsch-Woodill, M
Flanagan, JA
Prior, RL
机构
[1] Brunswick Labs, Wareham, MA 02571 USA
[2] US Dept Agr, Agr Res Serv, Arkansas Childrens Nutr Ctr, Little Rock, AR 72202 USA
关键词
ORAC; antioxidant activity; free radical; plate reader; high throughput;
D O I
10.1021/jf0201529
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
The oxygen radical absorbance capacity (ORAC) assay has-been widely accepted as a standard tool to measure the, antioxidant activity in the nutraceutical, pharmaceutical, and food industries. However, the ORAC assay has been criticized for a lack of accessibility due to the unavailability of the COBAS FARA II analyzer, an instrument discontinued by the manufacturer. In addition, the manual sample preparation is time-consuming and labor-intensive. The objective of this study was to develop a high-throughput instrument platform that can fully automate the ORAC assay procedure. The new instrument platform consists of a robotic eight-channel liquid handling system and a microplate fluorescence reader. By using the high-throughput platform, the efficiency of the assay is improved with at least a 10-fold increase in sample throughput over the current procedure. The mean of intra- and interday CVs was less than or equal to15%, and the limit of detection and limit of quantitation were 5 and 6.25 muM, respectively.
引用
收藏
页码:4437 / 4444
页数:8
相关论文
共 41 条
  • [21] High-throughput determination of fudosteine in human plasma by liquid chromatography-tandem mass spectrometry, following protein precipitation in the 96-well plate format
    Wen, Jun
    Wu, Yiwen
    Zhang, Linli
    Qi, Yunpeng
    Fan, Guorong
    Wu, Yutian
    Li, Zhen
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 867 (01): : 153 - 159
  • [22] High - throughput spectrofluorimetric approach for one-step, sensitive, and green assays of alfuzosin hydrochloride using a 96-well microplate reader: Application to tablet formulations and human urine
    Metias, Youstina M.
    Hosny, Mervat M.
    Ayad, Magda M.
    Kaji, Noritada
    TALANTA OPEN, 2022, 6
  • [23] Identification of Phenolic Compounds in Petals of Nasturtium Flowers (Tropaeolum majus) by High-Performance Liquid Chromatography Coupled to Mass Spectrometry and Determination of Oxygen Radical Absorbance Capacity (ORAC)
    Astrid Garzon, G.
    Manns, David C.
    Riedl, Ken
    Schwartz, Steven J.
    Padilla-Zakour, Olga
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2015, 63 (06) : 1803 - 1811
  • [24] Development of a high-throughput method for the determination of itraconazole and its hydroxy metabolite in human plasma, employing automated liquid–liquid extraction based on 96-well format plates and LC/MS/MS
    Constantinos Kousoulos
    Georgia Tsatsou
    Constantinos Apostolou
    Yannis Dotsikas
    Yannis L. Loukas
    Analytical and Bioanalytical Chemistry, 2006, 384 : 199 - 207
  • [25] The Use of Automated Solid Phase Extraction in the '96 well' Format for High Throughput Bioanalysis using Liquid Chromatography Coupled to Tandem Mass Spectrometry
    Allanson, J. P.
    Biddlecombe, R. A.
    Jones, A. E.
    Pleasance, S.
    Rapid Communications in Mass Spectrometry, 10 (07):
  • [26] Development of a high-throughput method for the determination of itraconazole and its hydroxy metabolite in human plasma, employing automated liquid-liquid extraction based on 96-well format plates and LC/MS/MS
    Kousoulos, C
    Tsatsou, G
    Apostolou, C
    Dotsikas, Y
    Loukas, YL
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 384 (01) : 199 - 207
  • [27] Bract as a novel extraction phase in thin-film SPME combined with 96-well plate system for the high-throughput determination of estrogens in human urine by liquid chromatography coupled to fluorescence detection
    do Carmo, Sangela Nascimento
    Merib, Josias
    Carasek, Eduardo
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2019, 1118 : 17 - 24
  • [28] Development and Validation of Semiautomated 96-Well Transport Assay Using LLC-PK1 Cells Transfected with Human P-Glycoprotein for High-Throughput Screening
    Miyamoto, Rei
    Nozawa, Takashi
    Kimura, Mayuko
    Shiozuka, Koichi
    Tabata, Kenji
    ASSAY AND DRUG DEVELOPMENT TECHNOLOGIES, 2015, 13 (02) : 79 - 87
  • [29] Development and Validation of a Selective and Robust LC-MS/MS Method, Employing Liquid-Liquid Extraction Based on 96-Well Format Plates, for High-Throughput Quantification of Docetaxel in Small Plasma Samples
    Wu, Yiwen
    Wen, Jun
    Fan, Guorong
    Wu, Yutian
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2009, 37 (01) : 1 - 22
  • [30] Hollow-fiber renewal liquid membrane extraction coupled with 96-well plate system as innovative high-throughput configuration for the determination of endocrine disrupting compounds by high-performance liquid chromatography-fluorescence and diode array detection
    Lopes, Daniela
    Dias, Adriana Neves
    Merib, Josias
    Carasek, Eduardo
    ANALYTICA CHIMICA ACTA, 2018, 1040 : 33 - 40