Accurate direct spectrophotometric bilirubin measurement combined with blood gas analysis

被引:15
|
作者
Laterza, OF
Smith, CH
Wilhite, TR
Landt, M
机构
[1] Washington Univ, Sch Med, Dept Pediat, St Louis, MO 63110 USA
[2] Washington Univ, Sch Med, Dept Pathol & Immunol, St Louis, MO 63110 USA
[3] St Louis Childrens Hosp, St Louis, MO 63110 USA
关键词
bilirubin; spectrophotometry; blood gas analysis; neonates;
D O I
10.1016/S0009-8981(02)00178-X
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: A new total bilirubin (B-T) method, based on multiple wavelength absorbance measurements, and an algorithm to calculate concentration, were evaluated for accuracy in specimens containing variable amounts of unconjugated bilirubin (B-U), conjugated bilirubin (B-C) and delta (protein-bound) bilirubin (B-D). Methods: Quantitation of B-U, B-C, and BT (with calculation of B-D) using a Vitros 250 analyzer served as the comparison method. Results: Analysis of neonatal specimens using a preliminary algorithm yielded good overall agreement with the Vitros BT method, but there was considerable variation in the agreement for individual specimens, When specimens from adults selected to yield a range of B-C and B-D levels were analyzed, the preliminary algorithm underestimated B-T. Refinement of the method in the form of a finalized algorithm resulted in elimination of the negative bias seen with specimens with high B-D and B-C levels, and better agreement for individual neonatal specimens. Conclusions: This now method overcomes the limitations observed in earlier spectrophotometric methods, and provides accurate results in specimens containing a range of bilirubin forms. (C) 2002 Elsevier Science B.V All rights reserved.
引用
收藏
页码:115 / 120
页数:6
相关论文
共 50 条
  • [21] IMPROVED METHOD FOR ACCURATE QUANTITATION OF TOTAL AND DIRECT BILIRUBIN IN SERUM
    NOVROS, JS
    KOCH, TR
    KNOBLOCK, EC
    CLINICAL CHEMISTRY, 1978, 24 (06) : 1022 - 1022
  • [22] CLINICAL EVALUATION OF A DIRECT SPECTROPHOTOMETRIC METHOD FOR NEONATAL BILIRUBIN ON THE DUPONT ACA
    BELL, GR
    JANOSEK, JP
    WHITE, JM
    BLIJENBERG, BG
    LEIJNSE, B
    CLINICAL CHEMISTRY, 1979, 25 (06) : 1126 - 1126
  • [23] Reactivity of bilirubin photoisomers on the measurement of direct bilirubin using vanadic acid method
    Okada, Hitoshi
    Itoh, Susumu
    Kawamoto, Shohei
    Ozaki, Miyo
    Kusaka, Takashi
    ANNALS OF CLINICAL BIOCHEMISTRY, 2018, 55 (02) : 296 - 298
  • [24] Neonatal hemoglobin affects the accuracy of whole blood bilirubin measurement on GEM Premier 4000 blood gas analyzers
    Huang, Yun
    Dean, Robert
    Dubbelman, Yvonne
    Vincent, Anne
    Khurshid, Faiza
    PRACTICAL LABORATORY MEDICINE, 2021, 25
  • [25] Effects of bilirubin configurational photoisomers on the measurement of direct bilirubin by the vanadate oxidation method
    Kawamoto, Shohei
    Koyano, Kosuke
    Ozaki, Miyo
    Arai, Takeshi
    Iwase, Takashi
    Okada, Hitoshi
    Itoh, Susumu
    Murao, Koji
    Kusaka, Takashi
    ANNALS OF CLINICAL BIOCHEMISTRY, 2021, 58 (04) : 311 - 317
  • [26] ACCURATE MEASUREMENT OF GAS SOLUBILITY
    COOK, MW
    HANSON, DN
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1957, 28 (05): : 370 - 374
  • [27] Transcutaneous bilirubin measurement in newborn infants: evaluation of a new spectrophotometric method
    Beck, M
    Kau, N
    Schlebusch, H
    ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2003, 88 (04): : 350 - 351
  • [28] RAPID AND ACCURATE SPECTROPHOTOMETRIC METHOD FOR TRUE LIPASE MEASUREMENT
    HUANG, CL
    ROY, AV
    CLINICAL CHEMISTRY, 1979, 25 (06) : 1067 - 1067
  • [29] Which Is More Accurate: Transcutaneous Bilirubin Measurement on the Forehead or Sternum?
    Shariati, Maryam Khoshnoud
    Taleghani, Naeeme Taslimi
    Izadi, Neda
    Miri, Aghil
    Tafti, Roya Taheri
    Gorji, Fatemeh Abdollah
    ARCHIVES OF IRANIAN MEDICINE, 2022, 25 (08) : 552 - 556
  • [30] SPECTROPHOTOMETRIC MEASUREMENT OF BILIRUBIN CONCENTRATIONS IN THE SERUM OF THE NEWBORN BY THE USE OF A MICROCAPILLARY METHOD
    WHITE, D
    ABUHAIDAR, G
    REINHOLD, JG
    CLINICAL CHEMISTRY, 1958, 4 (03) : 211 - 222