Operating a storage-augmented hybrid microgrid considering battery aging costs

被引:37
|
作者
Weitzel, Timm [1 ]
Schneider, Maximilian [2 ]
Glock, Christoph H. [1 ]
Loeber, Florian [3 ]
Rinderknecht, Stephan [2 ]
机构
[1] Tech Univ Darmstadt, Inst Prod & Supply Chain Management, Hochschulstr 1, D-64289 Darmstadt, Germany
[2] Tech Univ Darmstadt, Inst Mechatron Syst Mech Engn, Otto Berndt Str 2, D-64287 Darmstadt, Germany
[3] Tech Univ Darmstadt, Inst Prod Management Technol & Machine Tools, Otto Berndt Str 2, D-64287 Darmstadt, Germany
关键词
Battery energy storage; Battery aging costs; Hybrid microgrid; Thermal and electrical supply; Scheduling problem; Mixed integer linear programming; LITHIUM-ION BATTERIES; ELECTRICAL ENERGY-STORAGE; REALISTIC LIFETIME PREDICTIONS; DYNAMIC-MODEL VALIDATIONS; LEAD-ACID-BATTERIES; DISTRIBUTED GENERATION; CYCLE-LIFE; LIFEPO4/GRAPHITE CELL; CONTROL STRATEGIES; DEMAND RESPONSE;
D O I
10.1016/j.jclepro.2018.03.296
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Over the last decades, electricity demand and supply have become more decentralized, and the opportunities for locally managed microgrids have increased. Especially for residential microgrids consisting of multiple residential buildings equipped with a substantial share of local thermal and electrical energy production, flexibility is needed to balance energy demand and energy supply over time. Battery energy storage systems (BESSs) and thermal energy storage systems can provide this flexibility. Even though some BESS solutions are already available on the market, BESS still suffer from technical limitations and entail high investment costs. As BESS deteriorate over time depending on usage characteristics and the surrounding conditions, actively managing these parameters will largely affect their potential lifetime and the economic viability of their application. The majority of current research has focused on using BESS to optimize energy systems for economical, ecological, and technical objectives, but barely considered battery aging in the optimization models themselves. To contribute to closing this research gap, this article proposes an optimization model for the optimal day-ahead management of a multi-building district considering battery aging costs (BAC) derived from specific literature on battery degradation mechanisms. The resulting non-linear model is linearized and solved by using a commercial solver. Computational studies are performed to illustrate the case of a hybrid integrated local energy supplier responsible for the multi-building district, and sensitivities of its operating profits towards different sizing and pricing parameters are investigated. Results confirm the importance of considering BAC in decision support models for managing energy systems, both for a cost-efficient management of battery operations and to improve battery lifetime. The results also indicate that the application of BESS in day-ahead markets are only relevant for future cost levels of the technology. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:638 / 654
页数:17
相关论文
共 50 条
  • [21] Optimal Scheduling of an Isolated Microgrid With Battery Storage Considering Load and Renewable Generation Uncertainties
    Li, Yang
    Yang, Zhen
    Li, Guoqing
    Zhao, Dongbo
    Tian, Wei
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2019, 66 (02) : 1565 - 1575
  • [22] Optimal sizing of battery energy storage in a microgrid considering capacity degradation and replacement year
    Amini, Mohammad
    Khorsandi, Amir
    Vahidi, Behrooz
    Hosseinian, Seyed Hossein
    Malakmahmoudi, Ali
    ELECTRIC POWER SYSTEMS RESEARCH, 2021, 195
  • [23] Optimal sizing of battery energy storage in solar microgrid considering peak load shaving
    Guru N.
    Nayak M.R.
    Barisal A.K.
    Patnaik S.
    International Journal of Ambient Energy, 2023, 44 (01) : 2362 - 2371
  • [24] Operation Control Strategy of Microgrid Considering Grouping Optimization of Battery Energy Storage Units
    Yan G.
    Cai C.
    Duan S.
    Li H.
    Liu Y.
    Li J.
    Duan, Shuangming (duansm@neepu.edu.cn), 1600, Automation of Electric Power Systems Press (44): : 38 - 46
  • [25] Economic Dispatch of Microgrid Considering Fuzzy Control Based Storage Battery Charging and Discharging
    Mao, Wenjin
    Dai, Ning
    Li, Hongwei
    JOURNAL OF ELECTRICAL SYSTEMS, 2019, 15 (03) : 417 - 428
  • [26] Sizing of Microgrid System Including Multi-Functional Battery Storage and Considering Uncertainties
    Ibrahim, Ibrahim M.
    Abdelaziz, Almoataz Y.
    Alhelou, Hassan Haes
    Omran, Walid A.
    IEEE ACCESS, 2023, 11 : 29521 - 29540
  • [27] Reduction of Battery-Aging of a Hybrid Lithium-Ion and Vanadium-Redox-Flow Storage System in a Microgrid Application
    Resch, Simon
    Luther, Matthias
    2020 2ND IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL ELECTRONICS FOR SUSTAINABLE ENERGY SYSTEMS (IESES), 2020, : 80 - 85
  • [28] Optimization and energy management of a standalone hybrid microgrid in the presence of battery storage system
    Moradi, Hadis
    Esfahanian, Mandi
    Abtahi, Amir
    Zilouchian, Ali
    ENERGY, 2018, 147 : 226 - 238
  • [29] Energy Coordinated Control of Hybrid Battery-Supercapacitor Storage System in a Microgrid
    Mao, Meiqin
    Liu, Yuefan
    Jin, Peng
    Huang, Hui
    Chang, Liuchen
    2013 4TH IEEE INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS FOR DISTRIBUTED GENERATION SYSTEMS (PEDG), 2013,
  • [30] Battery Storage Services that Minimize Wind Farm Operating Costs: A Case Study
    Balischewski, Stephan
    Hauer, Ines
    Wolter, Martin
    Wenge, Christoph
    Lombardi, Pio
    Komarnicki, Przemyslaw
    2017 IEEE PES INNOVATIVE SMART GRID TECHNOLOGIES CONFERENCE EUROPE (ISGT-EUROPE), 2017,