Diagnostic Consistency and Relation Between Optical Coherence Tomography and Standard Automated Perimetry in Primary Open-Angle Glaucoma

被引:3
|
作者
Toprak, Ibrahim [1 ]
Yaylali, Volkan [2 ]
Yildirim, Cem [2 ]
机构
[1] Servergazi State Hosp, Dept Ophthalmol, Denizli, Turkey
[2] Pamukkale Univ, Fac Med, Dept Ophthalmol, Denizli, Turkey
关键词
Glaucoma; optical coherence tomography; retinal nerve fiber layer; visual field; SPECTRAL-DOMAIN OCT; FIBER LAYER THICKNESS; VISUAL-FIELD; PREPERIMETRIC GLAUCOMA; STRATUS OCT; GDX-VCC; NERVE; PROGRESSION; DEFECTS;
D O I
10.3109/08820538.2015.1046557
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess diagnostic consistency and relation between spectral-domain optical coherence tomography (SD-OCT) and standard automated perimetry (SAP) in patients with primary open-angle glaucoma (POAG). Methods: This retrospective study comprised 51 eyes of 51 patients with a confirmed diagnosis of POAG. The qualitative and quantitative SD-OCT parameters (retinal nerve fiber layer thicknesses [RNFL; average, superior, inferior, nasal and temporal], RNFL symmetry, rim area, disc area, average and vertical cup/disc [C/D] ratio and cup volume) were compared with parameters of SAP (mean deviation, pattern standard deviation, visual field index, and glaucoma hemifield test reports). Results: Fifty-one eyes of 51 patients with POAG were recruited. Twenty-nine eyes (56.9%) had consistent RNFL and visual field (VF) damage. However, nine patients (17.6%) showed isolated RNFL damage on SD-OCT and 13 patients (25.5%) had abnormal VF test with normal RNFL. In patients with VF defect, age, average C/D ratio, vertical C/D ratio, and cup volume were significantly higher and rim area was lower when compared to those of the patients with normal VF. In addition to these parameters, worsening in average, superior, inferior, and temporal RNFL thicknesses and RNFL symmetry was significantly associated with consistent SD-OCT and SAP outcomes. Conclusions: In routine practice, patients with POAG can be manifested with inconsistent reports between SD-OCT and SAP. An older age, higher C/D ratio, larger cup volume, and lower rim area on SD-OCT appears to be associated with detectable VF damage. Moreover, additional worsening in RNFL parameters might reinforce diagnostic consistency between SD-OCT and SAP.
引用
收藏
页码:185 / 190
页数:6
相关论文
共 50 条
  • [41] Anterior Segment Optical Coherence Tomography Angiography Imaging of Conjunctiva and Intrasclera in Treated Primary Open-Angle Glaucoma
    Akagi, Tadamichi
    Uji, Akihito
    Okamoto, Yoko
    Suda, Kenji
    Kameda, Takanori
    Nakanishi, Hideo
    Ikeda, Hanako Ohashi
    Miyake, Masahiro
    Nakano, Eri
    Motozawa, Naohiro
    Tsujikawa, Akitaka
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [42] Comparison of Pattern Electroretinography and Optical Coherence Tomography Parameters in Patients with Primary Open-Angle Glaucoma and Ocular Hypertension
    Demir, Semra Tiryaki
    Oba, Mehmet Ersin
    Erdogan, Ezgi Tuna
    Odabasi, Mahmut
    Dirim, Aye Burcu
    Demir, Mehmet
    Can, Efe
    Kara, Orhan
    Sendul, Selam Yekta
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2015, 45 (06): : 229 - 234
  • [43] USING AUTOMATED PERIMETRY TO SCREEN FOR OPEN-ANGLE GLAUCOMA IN A BLACK-POPULATION
    ODEN, NL
    LESKE, MC
    CONNELL, A
    TROUTMAN, T
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1992, 33 (04) : 757 - 757
  • [44] Primary Open-Angle Glaucoma: Diagnostic Approaches and Management
    Hazin, Ribhi
    Hendrick, Andrew M.
    Kahook, Malik Y.
    JOURNAL OF THE NATIONAL MEDICAL ASSOCIATION, 2009, 101 (01) : 46 - 50
  • [45] Diagnostic performance of wide-field optical coherence tomography angiography in detecting open-angle glaucoma in high myopia
    Zhang, Yinhang
    Wang, Deming
    Lin, Fengbin
    Song, Yunhe
    Chen, Yu
    Peng, Yuying
    Chen, Meiling
    Liu, Yuhong
    Jiang, Jiaxuan
    Yang, Zefeng
    Li, Fei
    Zhang, Xiulan
    ACTA OPHTHALMOLOGICA, 2024, 102 (02) : E168 - E177
  • [46] Ability of Optical Coherence Tomography in Early Detection of Primary Open Angle Glaucoma
    Jewariya, Pinky
    Sharma, Manisha
    Parwal, Sandeep
    Khilnani, Kamlesh
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2021, 15 (08)
  • [47] Correlation between optical coherence tomography, pattern electroretinogram, and visual evoked potentials in open-angle glaucoma patients
    Parisi, V
    Manni, G
    Centofanti, M
    Gandolfi, SA
    Olzi, D
    Bucci, MG
    OPHTHALMOLOGY, 2001, 108 (05) : 905 - 912
  • [48] Parapapillary choroidal microvascular density in acute primary angle-closure and primary open-angle glaucoma: an optical coherence tomography angiography study
    Suwan, Yanin
    Aghsaei Fard, Masoud
    Vilainerun, Nantinee
    Petpiroon, Purit
    Tantraworasin, Apichat
    Teekhasaenee, Chaiwat
    Ritch, Robert
    Kafieh, Rahele
    Hojati, Sahar
    Supakontanasan, Wasu
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2023, 107 (10) : 1438 - 1443
  • [49] A comparison of two optical coherence tomography-angiography devices in pseudoexfoliation glaucoma versus primary open-angle glaucoma and healthy subjects
    Rebolleda, Gema
    Perez-Sarriegui, Ane
    De Juan, Victoria
    Ortiz-Toquero, Sara
    Munoz-Negrete, Francisco J.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2019, 29 (06) : 636 - 644
  • [50] Short Wavelength Automated Perimetry, Standard Automated Perimetry, and Optical Coherence Tomography in Dominant Optic Atrophy
    Lombardo, Marco
    Cusumano, Andrea
    Mancino, Raffaele
    Aiello, Francesco
    Sorge, Roberto Pietro
    Nucci, Carlo
    Cesareo, Massimo
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (07)