Comparison of plasma densities measured by using electrical probes to those measured by using microwave probes in inductively coupled plasmas

被引:0
|
作者
Kim, Won-Ki [1 ]
Lee, Min-Hyong
Chung, Chin-Wook
机构
[1] Hanyang Univ, Dept Elect Engn, Seoul 133791, South Korea
[2] Korea Res Inst Stand & Sci, Ctr Vacuum Technol, Taejon 305306, South Korea
关键词
plasma density; electrical probe; microwave probe;
D O I
暂无
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The plasma density in an argon inductively coupled plasma is measured at a point by using two electrical probes (a single Langmuir probe and a double Langmuir probe) and two microwave probes (a cut-off probe and a hairpin probe). In the case of the single Langmuir probe, to avoid the effect of RF fluctuations, we adapt an RF compensated probe and obtain the electron density or the plasma density from the electron energy distribution function (EEDF) measurement through a proper integral. In the case of the double probe, the plasma density is derived from the ion current. Of the microwave probes, the cut-off probe appears to be the most reliable because it works regardless of sheath formation. The plasma density obtained by using the double probe is found to be larger than those obtained by using the other probes, and the plasma densities obtained by using the cut-off probe and the single probe are in good agreement, within 5%, over a wide range. The plasma density obtained by using the hairpin probe is observed to be 30% larger than that obtained by using the cut-off probe. This discrepancy seems to be due to the effect of the sheath on the hairpin probe.
引用
收藏
页码:1687 / 1690
页数:4
相关论文
共 50 条
  • [21] COMPARATIVE MEASUREMENTS OF COHERENT OSCILLATIONS AND TURBULENCE IN PLASMAS USING RESISTIVELY- AND CAPACITIVELY-COUPLED PROBES
    SERAFINI, JS
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1969, 14 (11): : 1011 - &
  • [22] Comparison of Serum Zinc Levels Measured by Inductively Coupled Plasma Mass Spectrometry in Preschool Children with Febrile and Afebrile Seizures
    Lee, Jun-Hwa
    Kim, Jeong Hyun
    ANNALS OF LABORATORY MEDICINE, 2012, 32 (03) : 190 - 193
  • [23] Relation between the CF2 radical and plasma density measured using LIF and cutoff probe in a CF4 inductively coupled plasma
    Kim, JH
    Shin, YH
    Chung, KH
    Yoo, YS
    APPLIED PHYSICS LETTERS, 2004, 85 (11) : 1922 - 1924
  • [24] Effect of electron kinetics on plasma density in inductively coupled plasmas using a passive resonant antenna
    Kim, Ju-Ho
    Chung, Chin-Wook
    PHYSICS OF PLASMAS, 2020, 27 (06)
  • [25] Measurements of absolute Cu, Zn and Sn metastable densities in CZTS sputtering plasmas measured using UVAS technique
    Nafarizal, Nayan
    Sasaki, Koichi
    2016 IEEE INTERNATIONAL CONFERENCE ON SEMICONDUCTOR ELECTRONICS (ICSE) PROCEEDINGS, 2016, : 252 - 255
  • [26] Absolute CO number densities measured using TALIF in a non-thermal plasma environment
    Damen, M. A.
    Hage, D. A. C. M.
    van de Steeg, A. W.
    Martini, L. M.
    Engeln, R.
    PLASMA SOURCES SCIENCE & TECHNOLOGY, 2019, 28 (11):
  • [27] Modeling the Rotational Dynamics of Novel Hetero-FRET Probes as Measured using Time-Resolved Anisotropy
    Leighton, Ryan E.
    Leopold, Hannah
    Schwarz, Jacob
    Boersma, Arnold J.
    Sheets, Erin D.
    Heikal, Ahmed A.
    BIOPHYSICAL JOURNAL, 2018, 114 (03) : 341A - 342A
  • [28] Subunit-Dependent Surface Mobility and Localization of NMDA Receptors in Hippocampal Neurons Measured Using Nanobody Probes
    Kortus, Stepan
    Rehakova, Kristyna
    Klima, Martin
    Kolcheva, Marharyta
    Ladislav, Marek
    Langore, Emily
    Barackova, Petra
    Netolicky, Jakub
    Misiachna, Anna
    Hemelikova, Katarina
    Humpolickova, Jana
    Chalupska, Dominika
    Silhan, Jan
    Kaniakova, Martina
    Krausova, Barbora Hrcka
    Boura, Evzen
    Zapotocky, Martin
    Horak, Martin
    JOURNAL OF NEUROSCIENCE, 2023, 43 (26): : 4755 - 4774
  • [29] Dark electrical bias effects on moisture-induced degradation in inverted lead halide perovskite solar cells measured by using advanced chemical probes
    Barbe, Jeremy
    Kumar, Vikas
    Newman, Michael J.
    Lee, Harrison K. H.
    Jain, Sagar M.
    Chen, Hu
    Charbonneau, Cecile
    Rodenburg, Cornelia
    Tsoi, Wing C.
    SUSTAINABLE ENERGY & FUELS, 2018, 2 (04): : 905 - 914
  • [30] Comparison of Microwave Ablation and Multipolar Radiofrequency Ablation In Vivo Using Two Internally Cooled Probes
    Fan, WeiJun
    Li, Xin
    Zhang, Liang
    Jiang, Hua
    Zhang, JianLei
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (01) : W46 - W50