Comparison of plasma densities measured by using electrical probes to those measured by using microwave probes in inductively coupled plasmas

被引:0
|
作者
Kim, Won-Ki [1 ]
Lee, Min-Hyong
Chung, Chin-Wook
机构
[1] Hanyang Univ, Dept Elect Engn, Seoul 133791, South Korea
[2] Korea Res Inst Stand & Sci, Ctr Vacuum Technol, Taejon 305306, South Korea
关键词
plasma density; electrical probe; microwave probe;
D O I
暂无
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The plasma density in an argon inductively coupled plasma is measured at a point by using two electrical probes (a single Langmuir probe and a double Langmuir probe) and two microwave probes (a cut-off probe and a hairpin probe). In the case of the single Langmuir probe, to avoid the effect of RF fluctuations, we adapt an RF compensated probe and obtain the electron density or the plasma density from the electron energy distribution function (EEDF) measurement through a proper integral. In the case of the double probe, the plasma density is derived from the ion current. Of the microwave probes, the cut-off probe appears to be the most reliable because it works regardless of sheath formation. The plasma density obtained by using the double probe is found to be larger than those obtained by using the other probes, and the plasma densities obtained by using the cut-off probe and the single probe are in good agreement, within 5%, over a wide range. The plasma density obtained by using the hairpin probe is observed to be 30% larger than that obtained by using the cut-off probe. This discrepancy seems to be due to the effect of the sheath on the hairpin probe.
引用
收藏
页码:1687 / 1690
页数:4
相关论文
共 50 条
  • [1] COMPARISON OF ELECTRON-DENSITIES MEASURED WITH LANGMUIR PROBES AND WITH TWO DIFFERENT MICROWAVE DEVICES
    KINDERDIJK, HM
    VANECK, J
    PHYSICA, 1972, 59 (02): : 257 - +
  • [2] Comparison of electron density measurements in planar inductively coupled plasmas by means of the plasma oscillation method and Langmuir probes
    Schwabedissen, A
    Benck, EC
    Roberts, JR
    PLASMA SOURCES SCIENCE & TECHNOLOGY, 1998, 7 (02): : 119 - 129
  • [3] ELECTRON TEMPERATURES AND ELECTRON NUMBER DENSITIES MEASURED BY THOMSON SCATTERING IN THE INDUCTIVELY COUPLED PLASMA
    HUANG, M
    MARSHALL, KA
    HIEFTJE, GM
    ANALYTICAL CHEMISTRY, 1986, 58 (01) : 207 - 210
  • [5] New cathodic protection criteria based on DC and AC current densities measured using probes for buried steel pipelines
    Hosokawa, Yuji
    Kajiyama, Fumio
    Nakamura, Yasuo
    Zairyo to Kankyo/ Corrosion Engineering, 2002, 51 (05): : 221 - 226
  • [6] Comparison of protein surface hydrophobicity measured at various pH values using three different fluorescent probes
    Alizadeh-Pasdar, N
    Li-Chan, ECY
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2000, 48 (02) : 328 - 334
  • [7] MEASURING PLASMA DRIFT VELOCITIES IN TOKAMAK EDGE PLASMAS USING PROBES
    STANGEBY, PC
    PHYSICS OF FLUIDS, 1984, 27 (11) : 2699 - 2704
  • [8] Comparison of fluctuations properties measured by Langmuir and ball-pen probes in the ISTTOK boundary plasma
    Silva, C.
    Adamek, J.
    Fernandes, H.
    Figueiredo, H.
    PLASMA PHYSICS AND CONTROLLED FUSION, 2015, 57 (02)
  • [9] Resistivity anisotropy measured using four probes in epitaxial graphene on silicon carbide
    Kobayashi, Keisuke
    Tanabe, Shinichi
    Tao, Takuto
    Okumura, Toshio
    Nakashima, Takeshi
    Aritsuki, Takuya
    Ryong-Sok, O.
    Nagase, Masao
    APPLIED PHYSICS EXPRESS, 2015, 8 (03)
  • [10] BEDSIDE GLUCOSE MONITORING - CURRENT PRACTICES MEASURED USING O-PROBES
    HOWANITZ, PJ
    JONES, BA
    CLINICAL CHEMISTRY, 1995, 41 (06) : S155 - S155