Modern Power Spectral Density Estimation of Discharge Pulses of Polluted Insulators

被引:0
|
作者
Tan, Wenqiang [1 ]
Zhu, Zhan [1 ,2 ]
Yao, Shuyou [2 ]
Xiong, Lan [2 ]
Zhang, Zhanlong [2 ]
机构
[1] Zigong Elect Power Co, Zigong 643000, Sichuan, Peoples R China
[2] Chongqing Univ, State Key Lab Power Transmiss Equipment & Sys Sec, Chongqing 400044, Peoples R China
关键词
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Although the insulation level of polluted insulators and the number of ultra-violet discharge pulses have close relationship, it is difficult to determine the insulation level of polluted insulators only by the number of discharge pulses. This paper illustrates the method of time-series analysis to study power spectral density (PSD) of ultra-violet discharge pulses from one string of 110kV polluted insulators, by applying Burg algorithm to establish the autoregressive model based on field data. Results indicate that different polluted level has its own corresponding curve, so it is possible to classify the insulation level of insulators through PSD method.
引用
收藏
页码:1390 / +
页数:2
相关论文
共 50 条
  • [21] Mapping Relation of Leakage Currents of Polluted Insulators and Discharge Arc Area
    Fang, Chunhua
    Tao, Yuning
    Wang, Jianguo
    Ding, Can
    Huang, Li
    Zhou, Mi
    Gu, Yi
    Wang, Yali
    FRONTIERS IN ENERGY RESEARCH, 2021, 9
  • [22] Additional salt deposit density of polluted insulators in salt fog
    Jiang, Xingliang
    Guo, Yujun
    Meng, Zhigao
    Li, Zhenyu
    Jiang, Zidan
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2016, 10 (15) : 3691 - 3697
  • [23] Comparison of arrival time estimation methods for partial discharge pulses in power cables
    Wagenaars, Paul
    Wouters, Peter A. A. F.
    van der Wielen, Peter C. J. M.
    Steennis, E. Fred
    PROCEEDINGS OF 2008 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS, 2007, : 1162 - +
  • [24] Flashover Mechanism and Prevention Measures of Polluted Insulators in Power System
    Wang Daxing
    Xu An
    Liu Ping
    Cui Tao
    2011 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2011,
  • [25] Variations in the Power Spectral Density of Thunderstorm Discharge Pulses in the Frequency Band of 12-40 kHz Associated with Earthquakes in Japan and Taiwan
    Kabanov, V. V.
    GEOMAGNETISM AND AERONOMY, 2019, 59 (01) : 76 - 89
  • [26] Cumulative power spectral density-based damping estimation
    Kim, Wonsul
    Hwang, Jae-Seung
    Kwon, Dae-Kun
    Kareem, Ahsan
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2024, 53 (05): : 1787 - 1802
  • [27] Power spectral density estimation from random interleaved samples
    Zhao Yijiu
    Yang Xi
    Wang Qi
    Liu Jingjing
    Fu Zaiming
    Zhang Peng
    Hu Lin
    PROCEEDINGS OF 2017 13TH IEEE INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS (ICEMI), VOL 1, 2017, : 76 - 79
  • [28] Optimum segmentation and windowing in nonparametric power spectral density estimation
    Beheshti, Soosan
    Pal, Sudeshna
    PROCEEDINGS OF THE 2007 15TH INTERNATIONAL CONFERENCE ON DIGITAL SIGNAL PROCESSING, 2007, : 379 - +
  • [29] Power spectral density peak estimation from broadband data
    Yoshida, Keiko
    JOURNAL OF SOUND AND VIBRATION, 2008, 312 (4-5) : 893 - 905
  • [30] Power spectral density estimation of noisy signal based on wavelet
    Jiang, Mingyan
    Pfletschinger, Stephan
    2007 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS, PROCEEDINGS, VOLS 1-8, 2007, : 1612 - 1616