Calibration issues of the Tokamak Fusion Test Reactor multichannel neutron collimator

被引:9
|
作者
vonGoeler, S
Johnson, LC
Bitter, M
Efthimion, PC
Roquemore, AL
机构
[1] Princeton Plasma Physics Laboratory, Princeton
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 1997年 / 68卷 / 01期
关键词
D O I
10.1063/1.1147649
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The calibration procedures for the detectors in the neutron collimator are reviewed. The absolute calibration was performed for the NE451 detectors, in situ, by moving a DT neutron generator in the Tokamak Fusion Test Reactor (TFTR) vacuum vessel across each sight line. This calibration was transferred to other detectors in the same channel. Four new sight Lines have been installed at a different toroidal location, which view the plasma through the vacuum vessel port cover rather than through thinned windows. The new detectors are cross calibrated to the NE451 detectors with a ''jog shot'' procedure, where the plasma is quickly shifted in major radius over a distance of 30 cm. The jog shot procedure shows that scattered neutrons account approximately for 30% of the signal of the new central channels. Corrections for detector nonlinearity are discussed. The neutron source strength from the collimator agrees within 10% with the source strength from global neutron monitors in the TFTR test cell. (C) 1997 American Institute of Physics.
引用
收藏
页码:548 / 551
页数:4
相关论文
共 50 条
  • [31] Recent progress on the Tokamak Fusion Test Reactor
    Meade, D.M.
    1997, Plenum Publ Corp, New York, NY, United States (15) : 3 - 4
  • [32] RADIOACTIVATION CHARACTERISTICS FOR THE TOKAMAK FUSION TEST REACTOR
    KU, LP
    KOLIBAL, JG
    NUCLEAR TECHNOLOGY-FUSION, 1983, 4 (03): : 586 - 598
  • [33] Tokamak fusion neutron source for a fast transmutation reactor
    Floyd, J.-P.
    Jones, S. M.
    Kato, M.
    Schultz, J. C.
    Shrader, B. H.
    Weathers, J. B.
    Stacey, W. M.
    Friis, Z. W.
    Johnson, R. W.
    FUSION SCIENCE AND TECHNOLOGY, 2007, 52 (03) : 727 - 730
  • [34] PERFORMANCE OF THE UPGRADED MULTICHANNEL NEUTRON COLLIMATOR
    ROQUEMORE, AL
    JOHNSON, LC
    VONGOELER, S
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (01): : 916 - 918
  • [35] MULTICHANNEL FAR-INFRARED LASER INTERFEROMETER FOR ELECTRON-DENSITY MEASUREMENTS ON THE TOKAMAK FUSION TEST REACTOR
    MANSFIELD, DK
    PARK, HK
    JOHNSON, LC
    ANDERSON, HM
    CHOUINARD, R
    FOOTE, VS
    MA, CH
    CLIFTON, BJ
    APPLIED OPTICS, 1987, 26 (20): : 4469 - 4474
  • [36] TRITIUM NEUTRAL BEAMS FOR THE TOKAMAK FUSION TEST REACTOR
    GRISHAM, LR
    DYLLA, HF
    WILLIAMS, MD
    WRIGHT, K
    CAUSEY, R
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 1989, 7 (03): : 944 - 948
  • [37] Tokamak fusion test reactor poloidal rotation diagnostic
    Rev Sci Instrum, 1 pt 2 (821):
  • [38] Final operations of the tokamak fusion test reactor (TFTR)
    von Halle, A
    17TH IEEE/NPSS SYMPOSIUM ON FUSION ENGINEERING, VOLS 1 AND 2, 1998, : 65 - 69
  • [39] DIFFUSION OF BEAM IONS AT THE TOKAMAK FUSION TEST REACTOR
    RUSKOV, E
    HEIDBRINK, WW
    BUDNY, RV
    NUCLEAR FUSION, 1995, 35 (09) : 1099 - 1113
  • [40] THE OPERATION OF THE TOKAMAK FUSION TEST REACTOR TRITIUM FACILITY
    GENTILE, CA
    ANDERSON, JL
    LAMARCHE, PH
    FUSION TECHNOLOGY, 1995, 28 (03): : 1327 - 1329