Experimental direct lightning current distribution in a reinforced concrete building

被引:1
|
作者
Sato, M [1 ]
Kuramoto, S
机构
[1] NTT, Serv Mkt & Support Headquarters, Tokyo 180, Japan
[2] NTT, Multimedia Networks Labs, Tokyo 180, Japan
来源
ELECTRONICS AND COMMUNICATIONS IN JAPAN PART I-COMMUNICATIONS | 2000年 / 83卷 / 04期
关键词
lightning surge; direct lightning; lightning protection; grounding; building;
D O I
10.1002/(SICI)1520-6424(200004)83:4<53::AID-ECJA6>3.0.CO;2-U
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
When a building is hit by a direct lightning strike, the communication equipment may be damaged due to the current flowing on the columns, girders, and walls. Therefore, it is necessary to determine the current distribution and establish preventive procedures. Previously, the linear model in which the columns and girders are expressed in terms of lumped elements has been used for estimation of the current distributions in the buildings. However, few buildings have been studied. It is very important to understand correspondence between the models and the actual structures, such as the treatment of the buildings' walls and floors. The researchers in the past have experimentally investigated the equivalent impedance of the columns and girders with complex shapes and measured the currents on the actual columns and girders by designing a large-diameter Rogowski coil. Based on these results, a Lightning current application experiment was carried out using a steel-reinforced concrete building and a model scale without walls and floors. The effects of the ground, walls, and floors were studied and a comparison was carried out with the conventional computational method using the Linear model. The current distribution characteristics of the columns and girders were revealed. It was shown that, in the calculation of the current distributions, the ground resistivity needs to be considered in addition to the equivalent impedance of the columns and girders. Also, in the case where the exterior of the building is concrete walls, the current flowing through the steel reinforcement of the exterior walls is about 30% of the current flowing into the building. (C) 1999 Scripta Technica, Electron Comm Jpn Pt 1, 83(4): 53-62, 2000.
引用
收藏
页码:53 / 62
页数:10
相关论文
共 50 条
  • [31] Lightning current distribution in lightning protection systems of structures
    Sowa, Andrzej
    Markowska, Renata
    Augustyniak, Leszek
    PRZEGLAD ELEKTROTECHNICZNY, 2008, 84 (10): : 263 - 265
  • [32] EXPERIMENTAL-STUDY OF RESPONSE OF POWER DISTRIBUTION LINES TO DIRECT LIGHTNING HITS
    YOKOYAMA, S
    ASAKAWA, A
    IEEE TRANSACTIONS ON POWER DELIVERY, 1989, 4 (04) : 2242 - 2248
  • [33] EFFECT OF CURRENT DISTRIBUTION ON CORROSION RATE MEASUREMENTS IN REINFORCED-CONCRETE
    FELIU, S
    GONZALEZ, JA
    ANDRADE, C
    CORROSION, 1995, 51 (01) : 79 - 86
  • [34] Design of Reinforced Concrete Shear Wall of Reactor Building, Experimental Power Reactor
    Suntoko, Hadi
    Iswanto, Eko Rudi
    Marwanto, Ary
    Puteraka, Antonius Mahatma
    SYMPOSIUM OF EMERGING NUCLEAR TECHNOLOGY AND ENGINEERING NOVELTY (SENTEN 2018), 2019, 1198
  • [35] Influence of lightning current waveform on magnetic fields in a building struck by lightning
    Wang, Q.
    Fu, Z.C.
    Zhou, Q.B.
    Du, Y.P.
    Gaodianya Jishu/High Voltage Engineering, 2001, 27 (01):
  • [36] Experimental Study of Competing Failure of Reinforced Concrete Based on the Weibull Distribution
    Feng, Qiong
    Qiao, Hongxia
    Wang, Penghui
    Zhu, Binrong
    Ndahirwa, Desire
    ADVANCES IN CIVIL ENGINEERING MATERIALS, 2018, 7 (01): : 520 - 537
  • [37] On the Influence of Steel Geometry on the Induced Currents in Steel Reinforced Concrete Building due to a Nearby Lightning Strike to Ground
    Hegde, Vishwanath
    Shivanand, Vinoda
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2015, 57 (03) : 418 - 424
  • [38] Observed direct lightning current distribution at a mountain-top radio relay station
    NTT Technical Assistance &, Support Cent, Musashino-shi, Japan
    IEICE Trans Commun, 4 (522-526):
  • [39] Observed direct lightning current distribution at a mountain-top radio relay station
    Sato, M
    Kuramoto, S
    IEICE TRANSACTIONS ON COMMUNICATIONS, 1996, E79B (04) : 522 - 527
  • [40] Direct lightning strikes to the lightning protective system of a residential building: Triggered-lightning experiments
    Rakov, VA
    Uman, MA
    Fernandez, MI
    Mata, CT
    Rambo, KJ
    Stapleton, MV
    Sutil, RR
    IEEE TRANSACTIONS ON POWER DELIVERY, 2002, 17 (02) : 575 - 586