Selective Detection of Hazardous Indoor VOCs Using Metal Oxide Gas Sensors

被引:47
|
作者
Leidinger, M. [1 ]
Sauerwald, T. [1 ]
Conrad, T. [2 ]
Reimringer, W. [2 ]
Ventura, G. [3 ]
Schuetze, A. [1 ]
机构
[1] Univ Saarland, Lab Measurement Technol, Campus A5 1, D-66123 Saarbrucken, Germany
[2] 3S GmbH, D-66121 Saarbrucken, Germany
[3] IDMEC Inst Mech Engeneering, Rua Dr Roberto Frias, P-4200465 Oporto, Portugal
来源
28TH EUROPEAN CONFERENCE ON SOLID-STATE TRANSDUCERS (EUROSENSORS 2014) | 2014年 / 87卷
关键词
Volatile Organic Compounds; Indoor Air Quality; Metal Oxide Gas Sensor; Temperature Cycled Operation;
D O I
10.1016/j.proeng.2014.11.722
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
A strategy for detecting and identifying trace levels of hazardous volatile organic compounds (VOCs) in indoor air is presented. A metal oxide semiconductor gas sensor in temperature cycled operation is used to detect formaldehyde, benzene and naphthalene in ppb and sub-ppb concentrations with a varying background of ethanol with concentrations of up to 2 ppm. Measurement results from a laboratory device have been compared with an integrated sensor system designed for use in field tests. We found that gas emissions from the system itself are an important issue. The emissions have been identified and quantified using analytical methods in order to derive design rules for a proper field test system. However, the results show that selective detection of VOCs in the ppb range is possible even with an intensive background of various VOCs, although sensitivity is reduced compared to the ideal laboratory case. (C) 2014 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:1449 / 1452
页数:4
相关论文
共 50 条
  • [21] Colorimetric Sensors for Toxic and Hazardous Gas Detection: A Review
    Cho, Sung Hwan
    Suh, Jun Min
    Eom, Tae Hoon
    Kim, Taehoon
    Jang, Ho Won
    ELECTRONIC MATERIALS LETTERS, 2021, 17 (01) : 1 - 17
  • [22] Colorimetric Sensors for Toxic and Hazardous Gas Detection: A Review
    Sung Hwan Cho
    Jun Min Suh
    Tae Hoon Eom
    Taehoon Kim
    Ho Won Jang
    Electronic Materials Letters, 2021, 17 : 1 - 17
  • [23] DETECTION OF GASEOUS HYDRIDES BY METAL-TITANIUM OXIDE GAS SENSORS
    TODA, K
    BUNSEKI KAGAKU, 1990, 39 (11) : 611 - 615
  • [24] Impedance based detection of HMDSO poisoning in metal oxide gas sensors
    Schueler, Marco
    Schneider, Tizian
    Sauerwald, Tilman
    Schuetze, Andreas
    TM-TECHNISCHES MESSEN, 2017, 84 (11) : 697 - 705
  • [25] DEVELOPMENT OF METAL-OXIDE-SEMICONDUCTOR SENSORS FOR THE DETECTION OF GAS TRACES
    FLEISCHMANN, D
    SCHWAB, H
    ENERGIETECHNIK, 1984, 34 (09): : 326 - 330
  • [26] Metal Oxide Nanowire Gas Sensors
    Hernandez-Ramirez, Francisco
    Daniel Prades, Juan
    Ramon Morante, Joan
    SENSORS AND MATERIALS, 2009, 21 (05) : 219 - 227
  • [27] Metal oxide gas sensors on the nanoscale
    Plecenik, A.
    Haidry, A. A.
    Plecenik, T.
    Durina, P.
    Truchly, M.
    Mosko, M.
    Grancic, B.
    Gregor, M.
    Roch, T.
    Satrapinskyy, L.
    Moskova, A.
    Mikula, M.
    Kus, P.
    MICRO- AND NANOTECHNOLOGY SENSORS, SYSTEMS, AND APPLICATIONS VI, 2014, 9083
  • [28] Detection of smoldering fire using tin oxide gas sensors
    Kanazawa Seiryo University
    不详
    不详
    不详
    不详
    不详
    IEEJ Trans. Sens. Micromach., 2007, 7 (353-358+4):
  • [29] Detection of CO and NO using low power metal oxide sensors
    Triantafyllopoulou, R.
    Tsamis, C.
    PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE, 2008, 205 (11): : 2643 - 2646
  • [30] Early stage fire detection using reliable metal oxide gas sensors and artificial neural networks
    Charumpom, B
    Yoshioka, M
    Fujinaka, T
    Omatu, S
    PROCEEDINGS OF THE INTERNATIONAL JOINT CONFERENCE ON NEURAL NETWORKS 2003, VOLS 1-4, 2003, : 3185 - 3188