A biomechanical comparison of two plating techniques in lateral clavicle fractures

被引:3
|
作者
Suter, Cyrill [1 ]
von Rohr, Martina [1 ]
Majewski, Martin [1 ]
Duerselen, Lutz [2 ]
Warnecke, Daniela [2 ]
Schild, Natalie [2 ]
Nowakowski, Andrej Maria [1 ,3 ]
机构
[1] Univ Basel, Med Fac, Klingelbergstr 61, CH-4056 Basel, Switzerland
[2] Ulm Univ, Med Ctr, Trauma Res Ctr Ulm, Inst Orthoped Res & Biomech, Helmholtzstr 14, D-89081 Ulm, Germany
[3] Spital Uster, Orthoped Dept, Brunnenstr 42, CH-8610 Uster, Switzerland
关键词
Lateral clavicle fracture; Biomechanical testing; Plate fixation; Single plate; Double plate; Surgical treatment; DISTAL CLAVICLE; SURGICAL-TREATMENT; TISSUE DIFFERENTIATION; FIXATION; LOCKING; STABILITY; EPIDEMIOLOGY; STIFFNESS; END; VASCULARIZATION;
D O I
10.1016/j.clinbiomech.2019.05.001
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Neer Type fib lateral clavicle fractures typically lead to dislocation of the medial fragment. Therefore, most surgeons recommend surgical treatment for such a fracture pattern. The use of a locking compression plate with a lateral extension has produced satisfactory results in various studies over recent years. Double-plate fixation is a common technique in the treatment of complex distal radius fractures. The authors use this technique as a routine procedure in the treatment of Neer type IIb fractures. In this biomechanical testing study, the mechanical properties of the two techniques were compared. Methods: On 20 clavicles from fresh frozen cadavers a Neer Type IIb fracture-like osteotomy was performed. A cyclic loading test followed by a load-to-failure test was carried out. Parameters for statistical evaluation were the stiffness at cycles 1, 100 and 17,500 as well as the ultimate tensile load and the deformation at the point of failure. Findings: All specimens withstood the cyclic loading test without any noticeable damage. At cycles 100 and 17,500, the double-plate technique was less stiff. Failure loads were not significantly different from each other, but deformation at the point of failure was significantly greater for the double-plate technique. Interpretation: Both techniques provided sufficient fixation to the fracture site to endure the cyclic loading test, which is supposed to simulate an incident-free week postoperatively. In summary, the double-plate technique offers biomechanically a feasible alternative to the single-plate technique in lateral clavicle fractures of Neer Type IIb.
引用
收藏
页码:78 / 84
页数:7
相关论文
共 50 条
  • [31] Biomechanical evaluation of clavicle fracture plating techniques: Does a locking plate provide improved stability?
    Celestre, Paul
    Roberston, Claire
    Mahar, Andrew
    Oka, Richard
    Meunier, Matthew
    Schwartz, Alexandra
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2008, 22 (04) : 241 - 247
  • [32] Anteroinferior Plating of Midshaft Clavicle Nonunions and Fractures
    Kloen, Peter
    Werner, Clement M. L.
    Stufkens, Sjoerd A. S.
    Helfet, David L.
    OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE, 2009, 21 (02): : 170 - 179
  • [33] Superior Versus Anteroinferior Plating of Clavicle Fractures
    Formaini, Nathan
    Taylor, Benjamin C.
    Backes, Jeffrey
    Bramwell, Thomas J.
    ORTHOPEDICS, 2013, 36 (07) : E898 - E904
  • [34] Feline Ilial Fractures: A Prospective Study of Dorsal Plating and Comparison with Lateral Plating
    Langley-Hobbs, Sorrel J.
    Meeson, Richard L.
    Hamilton, Michael H.
    Radke, Heidi
    Lee, Karla
    VETERINARY SURGERY, 2009, 38 (03) : 334 - 342
  • [35] Does dual plating clavicle fractures increase the risk of refracture after hardware removal? A biomechanical investigation
    Ruzbarsky, Joseph J.
    Nolte, Philip-C.
    Miles, Jon W.
    Tanghe, Kira K.
    Tross, Anna-K.
    Hackett, Thomas R.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2021, 30 (09) : E594 - E601
  • [36] Biomechanical Analysis of Combined Medial Calcar and Lateral Locked Plating Versus Isolated Lateral Locked Plating of Proximal Humerus Fractures
    Kotler, Joshua A.
    Zuppke, Julia N.
    Abraham, Vivek M.
    Sanville, Jennifer A.
    Nabet, Austin C.
    Carofino, Bradley
    Gardner, Michael J.
    Smith, Christopher S.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2023, 37 (09) : E355 - E360
  • [37] Operation techniques for clavicle fractures
    Trompetter, R.
    UNFALLCHIRURG, 2008, 111 (01): : 40 - 42
  • [38] Midshaft clavicle fractures: is anterior plating an acceptable alternative to superior plating?
    Brian H. Mullis
    Kyle J. Jeray
    Scott Broderick
    Stephanie L. Tanner
    Becky G. Snider
    Joshua Everhart
    European Journal of Orthopaedic Surgery & Traumatology, 2023, 33 : 3373 - 3377
  • [39] Midshaft clavicle fractures: is anterior plating an acceptable alternative to superior plating?
    Mullis, Brian J.
    Jeray, Kyle
    Broderick, Scott L.
    Tanner, Stephanie G.
    Snider, Becky
    Everhart, Joshua
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2023, 33 (08): : 3373 - 3377
  • [40] Biomechanical comparison of anatomical plating systems for comminuted distal humeral fractures
    Varady, Patrick A.
    von Rueden, Christian
    Greinwald, Markus
    Hungerer, Sven
    Paetzold, Robert
    Augat, Peter
    INTERNATIONAL ORTHOPAEDICS, 2017, 41 (09) : 1709 - 1714