GdxSi grown with mass-analyzed low energy dual ion beam epitaxy technique

被引:5
|
作者
Zhou, JP [1 ]
Chen, NF [1 ]
Zhang, FQ [1 ]
Song, SL [1 ]
Chai, CL [1 ]
Yang, SY [1 ]
Liu, ZK [1 ]
Lin, LY [1 ]
机构
[1] Chinese Acad Sci, Inst Semicond, Lab Semicond Mat Sci, Beijing 100083, Peoples R China
基金
中国国家自然科学基金;
关键词
Auger electron spectroscopy; X-ray diffraction; X-ray photoelectron spectroscopy; ion beam epitaxy; semiconducting gadolinium silicide;
D O I
10.1016/S0022-0248(02)01433-1
中图分类号
O7 [晶体学];
学科分类号
0702 ; 070205 ; 0703 ; 080501 ;
摘要
Semiconducting gadolinium silicide GdxSi samples were prepared by mass-analyzed low-energy dual ion beam epitaxy technique. Auger electron spectroscopy depth profiles indicate that the gadolinium ions are implanted into the single-crystal silicon substrate and formed 20 nm thick GdxSi film. X-ray double-crystal diffraction measurement shows that there is no new phase formed. The XPS spectra show that one type of silicon peaks whose binding energy is between that of silicide and silicon dioxide, and the gadolinium peak of binding energy is between that of metal Gd and Gd2O3. All of these results indicate that an amorphous semiconductor is formed. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:389 / 394
页数:6
相关论文
共 50 条
  • [41] CORRELATION OF KINETIC-ENERGY RELEASE WITH THE STRUCTURE OF SELECTED CHLORINATED COMPOUNDS IN MASS-ANALYZED ION KINETIC-ENERGY SPECTROMETRY
    VOYKSNER, RD
    HASS, JR
    BURSEY, MM
    ANALYTICAL CHEMISTRY, 1983, 55 (06) : 914 - 920
  • [42] Ge/Si quantum dot nanostructures grown with low-energy ion beam-assisted epitaxy
    Dvurechenskii, AV
    Smagina, JV
    Groetzschel, R
    Zinovyev, VA
    Armbrister, VA
    Novikov, PL
    Teys, SA
    Gutakovskii, AK
    SURFACE & COATINGS TECHNOLOGY, 2005, 196 (1-3): : 25 - 29
  • [43] Ionization energy of acetone by vacuum ultraviolet mass-analyzed threshold ionization spectrometry
    Jae Han Kim
    Do Won Kang
    Yong Jun Hong
    Hyonseok Hwang
    Hong Lae Kim
    Chan Ho Kwon
    Hyperfine Interactions, 2013, 216 : 85 - 88
  • [44] Ionization energy of acetone by vacuum ultraviolet mass-analyzed threshold ionization spectrometry
    Kim, Jae Han
    Kang, Do Won
    Hong, Yong Jun
    Hwang, Hyonseok
    Kim, Hong Lae
    Kwon, Chan Ho
    HYPERFINE INTERACTIONS, 2013, 216 (1-3): : 85 - 88
  • [45] A DATA ACQUISITION-SYSTEM FOR MASS-ANALYZED ION KINETIC-ENERGY SPECTRA USING A PERSONAL-COMPUTER
    TRAEGER, JC
    MOMMERS, AA
    ORGANIC MASS SPECTROMETRY, 1987, 22 (09): : 592 - 596
  • [46] DETERMINATION OF ANTHRACENE AND PHENANTHRENE IN DIESEL PARTICULATES BY COLLISIONALLY ACTIVATED DECOMPOSITION MASS-ANALYZED ION KINETIC-ENERGY SPECTROMETRY
    DORETTI, L
    MACCIONI, AM
    TRALDI, P
    BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY, 1986, 13 (07): : 381 - 385
  • [47] THE DESIGN AND PERFORMANCE EVALUATION OF A NEW HIGH-PERFORMANCE MASS-ANALYZED ION KINETIC-ENERGY (MIKE) SPECTROMETER
    RUSSELL, DH
    SMITH, DH
    WARMACK, RJ
    BERTRAM, LK
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1980, 35 (3-4) : 381 - 391
  • [48] ANALYSIS OF A MASS-ANALYZED ION KINETIC-ENERGY PROFILE .2. SYSTEMATIC DETERMINATION OF THE KINETIC-ENERGY RELEASE DISTRIBUTION
    YEH, IC
    KIM, MS
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1992, 6 (04) : 293 - 297
  • [49] MOLECULAR-BEAM EPITAXY OF GAAS USING A MASS-SEPARATED, LOW-ENERGY AS+ ION-BEAM
    SHIMIZU, S
    TSUKAKOSHI, O
    KOMIYA, S
    MAKITA, Y
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1985, 3 (02): : 554 - 559
  • [50] A DUAL ION-BEAM EPITAXY SYSTEM
    SU, SJ
    JIANG, WS
    QIN, FG
    WANG, XM
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1992, 70 (1-4): : 579 - 582