The Spider differential mobility analyzer (DMA) is a novel, miniaturized radial DMA developed to provide size classification in the 10-500 nm range for applications requiring high portability and time resolution. Its external dimensions are similar to 12 cm in diameter by 6 cm in height (excluding tubing); it weighs similar to 350 g, and is designed to operate at 0.6-1.5 L/min sheath and 0.3 L/min sample flowrates. It features a new sample inlet geometry that is designed to produce a uniform azimuthal particle distribution at the entrance of the classifier, optimized sample/sheath flow streams introduction in the classifier to minimize particle delays, and extension of the electric field interaction volume for similar to 30% enhanced dynamic range. Based on three-dimensional finite element simulations of flows, electric fields, and particle trajectories, we demonstrate that the Spider DMA transfer functions can be predicted with high fidelity using a parameterized fit based on the Stolzenburg semi-analytical model. Experimental characterization of the instrument response with size-selected particles confirmed close agreement with model prediction; mobility size response is linear over three orders of magnitude in mobility span. Electrical ground shielding of the external surfaces of the DMA has been found to be necessary to avoid particle losses associated with field effects as the high voltage operating limit is approached. The mean deviation between the reference size of polystyrene latex spheres and the Spider DMA measurement is less than 2%, corroborating its high sizing precision and potential for high quality size distribution measurements. Copyright (c) 2019 American Association for Aerosol Research
引用
收藏
页码:175 / 189
页数:15
相关论文
共 50 条
  • [1] Radial differential mobility analyzer
    Department of Chemical Engineering, California Institute of Technology, Pasadena, CA 91125, United States
    AEROSOL SCI. TECHNOL., 3 (357-372):
  • [2] RADIAL DIFFERENTIAL MOBILITY ANALYZER
    ZHANG, SH
    AKUTSU, Y
    RUSSELL, LM
    FLAGAN, RC
    SEINFELD, JH
    AEROSOL SCIENCE AND TECHNOLOGY, 1995, 23 (03) : 357 - 372
  • [3] Resolution of the radial differential mobility analyzer for ultrafine particles
    Zhang, SH
    Flagan, RC
    JOURNAL OF AEROSOL SCIENCE, 1996, 27 (08) : 1179 - 1200
  • [4] A Differential Mobility Analyzer (DMA) for Size Selection of Nanoparticles at High Flow Rates
    Hontanon, E.
    Kruis, F. E.
    AEROSOL SCIENCE AND TECHNOLOGY, 2009, 43 (01) : 25 - 37
  • [5] Design and evaluation of a nanometer aerosol differential mobility analyzer (Nano-DMA)
    Chen, DR
    Pui, DYH
    Hummes, D
    Fissan, H
    Quant, FR
    Sem, GJ
    JOURNAL OF AEROSOL SCIENCE, 1998, 29 (5-6) : 497 - 509
  • [6] Miniature differential mobility analyzer for compact field-portable spectrometers
    Qi, Chaolong
    Kulkarni, Pramod
    AEROSOL SCIENCE AND TECHNOLOGY, 2016, 50 (11) : 1145 - 1154
  • [7] Radial Differential Mobility Analyzer for One Nanometer Particle Classification
    Brunelli, N. A.
    Flagan, R. C.
    Giapis, K. P.
    AEROSOL SCIENCE AND TECHNOLOGY, 2009, 43 (01) : 53 - 59
  • [8] Determination of Aerosol Particle Size Distribution using Electrical Differential Mobility Analyzer (DMA)
    Fasih-Ramandi, Fatemeh
    Sadigzadeh, Asghar
    Jafari, Mohammad-Javad
    Khodakarim, Soheila
    JOURNAL OF HEALTH AND SAFETY AT WORK, 2021, 11 (01) : 92 - 105
  • [9] A cost-effective differential mobility analyzer (cDMA) for multiple DMA column applications
    Mei, Fan
    Fu, Huijing
    Chen, Da-Ren
    JOURNAL OF AEROSOL SCIENCE, 2011, 42 (07) : 462 - 473
  • [10] Nanometer differential mobility analyzer (Nano-DMA): Experimental evaluation and performance verification
    Gerhard-Mercator-Univ, Duisburg, Germany
    J Aerosol Sci, Suppl 1 (S135-S136):