Need for lateral bone augmentation at two narrow-diameter implants: A prospective, controlled, clinical study

被引:16
|
作者
Roccuzzo, Andrea [1 ,2 ]
Imber, Jean-Claude [1 ,3 ]
Jensen, Simon Storgard [2 ,4 ]
机构
[1] Univ Bern, Sch Dent Med, Dept Periodontol, Freiburgstr 7, CH-3010 Bern, Switzerland
[2] Copenhagen Univ Hosp, Dept Oral & Maxillofacial Surg, Rigshosp, Copenhagen, Denmark
[3] Johannes Gutenberg Univ Mainz, Univ Med Ctr, Dept Periodontol & Operat Dent, Mainz, Germany
[4] Univ Copenhagen, Fac Hlth Sci, Sch Dent, Dept Oral & Maxillofacial Surg, Copenhagen, Denmark
关键词
narrow diameter; small diameter implants; congenitally missing teeth; bone regeneration;
D O I
10.1111/clr.13721
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives To detect the potential influence of implant diameter and anatomic factors on the need for bone augmentation procedures (BAPs) when replacing congenitally missing lateral incisors (MLIs). Materials and methods Patients with congenitally missing MLIs with a mesio-distal distance between the canine and the central incisor of 5.9-6.3 mm received a o2.9 mm implant while o3.3 mm implants were placed when the distance was 6.4-7.1 mm. The following linear measurements were recorded using a calliper: width of the alveolar process (WAP), width of the bony alveolar ridge (WAR) and thickness of the facial bone after implant osteotomy (TFB). Guided bone regeneration was performed in case of fenestration- or dehiscence-type defects or a thin TFB (<1.7 mm). Results Fifty o2.9 mm and 50 o3.3 mm were included in 100 patients. WAP and WAR did not differ between the groups (p > .05). TFB was statistically significant larger in the o2.9 group (1.75 +/- 0.59 mm) compared to the o3.3 group (1.5 +/- 0.63 mm) (p = .041). Fenestration-type defects (p = .005) and a thin facial bone wall (p = .045) was observed more frequently in the o3.3 compared to the o2.9 group. Correspondingly, BAP was indicated more frequently in the o3.3 compared to the o2.9 group (p = .017). WAP, MD and WAR were statistically significant correlated to the need for BAP (p < .001). As independent variable, only WAR influenced the probability of BAP (p < .001). Conclusion The use of 2.9 diameter implants was correlated to a reduced frequency of BAP compared to 3.3 mm implants, without reaching a statistically significant difference. Measurement of the WAP provides the clinician useful information to predict BAP.
引用
收藏
页码:511 / 520
页数:10
相关论文
共 50 条
  • [31] Primary stability of narrow-diameter dental implants with a multiple condensing thread design placed in bone with and without osteotomes: An in vitro study
    Romanos, Georgios E.
    Lau, Jessica
    Delgado-Ruiz, Rafael
    Javed, Fawad
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2020, 22 (03) : 409 - 414
  • [32] Long-term clinical study of fixed prosthetic rehabilitation using one-piece narrow-diameter implants: a retrospective study
    Kim, Jong-Hee
    Nam, Jung Hyun
    Chang, Na-Hee
    Yi, Yang-Jin
    JOURNAL OF THE KOREAN ASSOCIATION OF ORAL AND MAXILLOFACIAL SURGEONS, 2024, 50 (06) : 343 - 349
  • [33] Clinical outcome of narrow diameter implants: A retrospective study of 510 implants
    Degidi, Marco
    Piattelli, Adriano
    Carinci, Francesco
    JOURNAL OF PERIODONTOLOGY, 2008, 79 (01) : 49 - 54
  • [34] Titanium-zirconium narrow-diameter versus titanium regular-diameter implants for anterior and premolar single crowns: 1-year results of a randomized controlled clinical study
    Benic, Goran I.
    Gallucci, German O.
    Mokti, Muizzaddin
    Haemmerle, Christoph H. F.
    Weber, Hans-Peter
    Jung, Ronald E.
    JOURNAL OF CLINICAL PERIODONTOLOGY, 2013, 40 (11) : 1052 - 1061
  • [35] Effect of microthreads on coronal bone healing of narrow-diameter implants with reverse-tapered design in beagle dogs
    Chang, Yun-Young
    Kim, Su-Hwan
    Park, Keun-Oh
    Yun, Jeong-Ho
    CLINICAL ORAL IMPLANTS RESEARCH, 2017, 28 (12) : 1532 - 1542
  • [36] Narrow diameter implants to replace congenital missing maxillary lateral incisors: A 1-year prospective, controlled, clinical study (vol 33, pg 844, 2022)
    Roccuzzo, A.
    Imber, J. - C.
    Lempert, J.
    Hosseini, M.
    Jensen, S. S.
    CLINICAL ORAL IMPLANTS RESEARCH, 2022, 33 (11) : 1182 - 1182
  • [37] Evaluation of a Reverse-Tapered Design on the Osseointegration of Narrow-Diameter Implants in Beagle Dogs: A Pilot Study
    Chang, Yun-Young
    Kim, Su-Hwan
    Park, Keun-Oh
    Yun, Jeong-Ho
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2016, 31 (03) : 611 - 620
  • [38] Use of narrow-diameter implants in the posterior segments of the jaws: A retrospective observational study of 2 to 11 years
    Assaf, Andre
    Saad, Moustapha
    Hijawi, Saleh
    JOURNAL OF PROSTHETIC DENTISTRY, 2023, 130 (06): : 840 - 848
  • [39] Clinical performance of narrow-diameter titanium–zirconium implants in immediately loaded fixed full-arch prostheses: a 2-year clinical study
    Fatih Mehmet Coskunses
    Önjen Tak
    International Journal of Implant Dentistry, 7
  • [40] Narrow-diameter versus standard-diameter implants placed in horizontally regenerated bone in the rehabilitation of partially and completely edentulous patients: A systematic review
    Valente, Nicola Alberto
    Marchio, Vincenzo
    Troiano, Giuseppe
    Gasparro, Roberta
    Balice, Pierluigi
    Marenzi, Gaetano
    Laino, Luigi
    Sammartino, Gilberto
    Iezzi, Giovanna
    Barone, Antonio
    INTERNATIONAL JOURNAL OF ORAL IMPLANTOLOGY, 2022, 15 (01) : 13 - 29