Particulate Air Pollution at Schools: Indoor-Outdoor Relationship and Determinants of Indoor Concentrations

被引:38
|
作者
Mohammadyan, Mahmoud [1 ]
Alizadeh-Larimi, Ahmad [2 ]
Etemadinejad, Siavash [1 ]
Latif, Mohd Talib [3 ,4 ]
Heibati, Behzad [5 ]
Yetilmezsoy, Kaan [6 ]
Abdul-Wahab, Sabah Ahmed [7 ]
Dadvand, Payam [8 ,9 ,10 ]
机构
[1] Mazandaran Univ Med Sci, Fac Hlth, Hlth Sci Res Ctr, Sari, Iran
[2] Mazandaran Univ Med Sci, Fac Hlth, Sari, Iran
[3] Univ Kebangsaan Malaysia, Sch Environm & Nat Resource Sci, Fac Sci & Technol, Bangi 43600, Selangor, Malaysia
[4] Univ Kebangsaan Malaysia, Inst Environm & Dev LESTARI, Bangi, Malaysia
[5] Mazandaran Univ Med Sci, Fac Hlth, Hlth Sci Res Ctr, Student Res Comm, Sari, Iran
[6] Yildiz Tech Univ, Dept Environm Engn, Fac Civil Engn, Istanbul, Turkey
[7] Sultan Qaboos Univ, Dept Mech & Ind Engn, Coll Engn, Muscat 123, Oman
[8] ISGlobal, Ctr Res Environm Epidemiol CREAL, Barcelona 08003, Spain
[9] Pompeu Fabra Univ, Barcelona 08003, Spain
[10] Ciber Epidemiol & Publ Hlth CIBERESP, Madrid 28029, Spain
关键词
Classrooms; Particulate matter; PM2.5; PM10; Iran; PM2.5; EXPOSURE; MATTER; BARCELONA; PM10; HOME;
D O I
10.4209/aaqr.2016.03.0128
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study aimed to assess the relationship between indoor and outdoor particulate air pollution at primary schools, and identify the determinants of indoor pollution concentrations. The study was conducted in six classrooms within six primary schools in Sari, Northern Iran. Indoor concentrations of particulate matter (PM) with an aerodynamic diameter of less than 10 mu m (PM10), 2.5 mu m (PM2.5), and 1 mu m (PM1.0) were assessed in classrooms, and outdoor concentrations of PM2.5 on the school playgrounds were monitored simultaneously by using two real-time and portable dust monitors during autumn, winter, and spring, yielding 26 sampling days for each school in total. The highest outdoor and indoor PM2.5 concentrations were found in winter and spring, respectively. The mean indoor PM2.5 concentration (46.9 +/- 32.9 mu g m(-3)) was higher than that measured outdoors (36.8 +/- 33.2 mu g m(-3)). Indoor PM2.5 and PM1.0 were moderately correlated with outdoor PM2.5 concentrations, which was the main determinant for all indoor particulate concentrations, however, a distinct pattern was observed for PM10 and PM2.5 compared to PM1.0. While meteorological variables (i.e., ambient temperature, relative humidity) could predict indoor PM10 and PM2.5 concentrations, the total area of the windows and the number of students in a classroom were predictors for PM1.0 levels. The findings of this study could inform policy makers in implementing evidence-based targeted interventions aimed at reducing air pollution in school settings.
引用
收藏
页码:857 / 864
页数:8
相关论文
共 50 条
  • [21] Indoor-outdoor relationship of suspended particulate matter and its chemical composition at different sizes
    El-Abssawy, AA
    INTERNATIONAL JOURNAL OF ENVIRONMENT AND POLLUTION, 2003, 19 (06) : 615 - 634
  • [22] INDOOR-OUTDOOR AIR-QUALITY RELATIONSHIPS - DISCUSSION
    HOWLETT, CT
    JOURNAL OF THE AIR POLLUTION CONTROL ASSOCIATION, 1982, 32 (09): : 913 - 916
  • [23] INDOOR-OUTDOOR AIR-QUALITY RELATIONSHIPS - COMMENTS
    MACRISS, RA
    JOURNAL OF THE AIR POLLUTION CONTROL ASSOCIATION, 1982, 32 (09): : 919 - 919
  • [24] INDOOR-OUTDOOR AIR-POLLUTION, ALLERGEN AND METEOROLOGICAL MONITORING IN AN ARID SOUTHWEST AREA
    LEBOWITZ, MD
    CORMAN, G
    OROURKE, MK
    HOLBERG, CJ
    JOURNAL OF THE AIR POLLUTION CONTROL ASSOCIATION, 1984, 34 (10): : 1035 - 1038
  • [25] Indoor-Outdoor Air Pollution Continuum and CVD Burden An Opportunity for Improving Global Health
    Rajagopalan, Sanjay
    Brook, Robert D.
    GLOBAL HEART, 2012, 7 (03) : 207 - 213
  • [26] Correlation of indoor-outdoor air quality in urban areas
    El-Hougeiri, N
    El Fadel, M
    INDOOR AND BUILT ENVIRONMENT, 2004, 13 (06) : 421 - 431
  • [27] Indoor-outdoor image classification
    Szummer, M
    Picard, RW
    1998 IEEE INTERNATIONAL WORKSHOP ON CONTENT-BASED ACCESS OF IMAGE AND VIDEO DATABASE, PROCEEDINGS, 1998, : 42 - 51
  • [28] The indoor-outdoor radio environment
    Saunders, SR
    Kelly, K
    Jones, SMR
    Dell'Anna, M
    Harrold, TJ
    ELECTRONICS & COMMUNICATION ENGINEERING JOURNAL, 2000, 12 (06): : 249 - 261
  • [29] Indoor-outdoor relationship of SO2 concentrations in a rural and an urban community of Alberta
    Kindzierski, W
    Sembaluk, S
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 2001, 28 : 163 - 169
  • [30] Levels and Indoor-Outdoor Relationships of Size-Specific Particulate Matter in Naturally Ventilated Portuguese Schools
    Madureira, Joana
    Paciencia, Ines
    Fernandes, Eduardo de Oliveira
    JOURNAL OF TOXICOLOGY AND ENVIRONMENTAL HEALTH-PART A-CURRENT ISSUES, 2012, 75 (22-23): : 1423 - 1436