Assessment of left atrial volume and function in patients with permanent atrial fibrillation: comparison of cardiac magnetic resonance imaging, 320-slice multi-detector computed tomography, and transthoracic echocardiography

被引:65
|
作者
Agner, Bue F. Ross [1 ]
Kuhl, Jorgen Tobias [2 ]
Linde, Jesper James [1 ]
Kofoed, Klaus F. [2 ,3 ]
Akeson, Per [4 ]
Rasmussen, Bo V. [1 ]
Jensen, Gorm B. [1 ]
Dixen, Ulrik [1 ]
机构
[1] Hvidovre Univ Hosp, Dept Cardiol, DK-2650 Copenhagen, Denmark
[2] Univ Copenhagen, Rigshosp, Ctr Heart, Dept Cardiol, DK-2100 Copenhagen, Denmark
[3] Univ Copenhagen, Rigshosp, Ctr Diagnost, Dept Radiol, DK-2100 Copenhagen, Denmark
[4] Hvidovre Univ Hosp, Danish Res Ctr Magnet Resonance, Copenhagen, Denmark
关键词
atrial fibrillation; cardiac magnetic resonance; transthoracic echocardiography; multi-detector computed tomography; left atrial volume; left atrial function; PULMONARY VEIN ISOLATION; 2-DIMENSIONAL ECHOCARDIOGRAPHY; VENTRICULAR VOLUME; RECURRENCE; PERSISTENT; REPRODUCIBILITY; VALIDATION; PREDICTORS; ABLATION; RISK;
D O I
10.1093/ehjci/jet239
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Atrial fibrillation (AF) is a common cardiac arrhythmia that is associated with substantial morbidity and mortality. AF is associated with enlargement of the left atrium (LA), and the LA volume has important prognostic implications for the disease. The objective of the study was to determine how measurements of LA volume and function obtained by transthoracic echocardiography (TTE), cardiac magnetic resonance (CMR), and 320-slice multi-detector computed tomography (MDCT) correlate in patients with permanent AF. Thirty-four patients with permanent AF participated in the study. TTE, CMR, and 320-slice MDCT imaging procedures were performed within 7 4 days. 320-slice MDCT overestimated maximal LA volume (LAmax) and minimal LA volume (LAmin) compared with CMR (LAmax: 80 vs. 73 mL/m(2), P = 0.0017; LAmin: 69 vs. 64 mL/m(2), P = 0.0217), whereas TTE underestimated these parameters compared with CMR (LAmax: 60 vs. 73 mL/m(2), P < 0.0001; LAmin: 50 vs. 64 mL/m(2), P < 0.0001), and also compared with MDCT (LAmax: 60 vs. 80 mL/m(2), P < 0.0001; LAmin: 50 vs. 69 mL/m(2), P < 0.0001). Measurements of LA volumes by MDCT and CMR closely correlated, and both MDCT and CMR had excellent intra- and inter-observer agreement with correlation coefficients of 0.90. The correlation between TTE-derived measurements and CMR/MDCT was fair to moderate. Intra- and inter-observer agreement for LA volume measurements by TTE were inferior to CMR and MDCT. Measurements of LA volumes by CMR and 320-slice MDCT correlate closely in patients with permanent AF, and both modalities improve the reproducibility of measurements of LA volumes and function compared with 2D TTE.
引用
收藏
页码:532 / 540
页数:9
相关论文
共 50 条
  • [21] Relationship between left atrial appendage emptying and left atrial function using cardiac magnetic resonance in patients with atrial fibrillation: comparison with transesophageal echocardiography
    Hwang, Sung Ho
    Oh, Yu-Whan
    Kim, Mi-Na
    Park, Seong-Mi
    Shim, Wan Joo
    Shim, Jaemin
    Choi, Jong-il
    Kim, Young-Hoon
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2016, 32 : S163 - S171
  • [22] Quantitative evaluation of right atrial volume and right atrial emptying fraction by 320-slice computed tomography compared with three-dimensional echocardiography
    Takahashi, Akiyo
    Funabashi, Nobusada
    Kataoka, Akihisa
    Yajima, Rei
    Takahashi, Maiko
    Uehara, Masae
    Takaoka, Hiroyuki
    Saito, Mariko
    Yamaguchi, Chiharu
    Lee, Kwangho
    Komuro, Issei
    Nomura, Fumio
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2011, 146 (01) : 96 - 99
  • [23] Assessment of left ventricular ejection fraction: comparison of two dimensional echocardiography, cardiac magnetic resonance imaging and 64-row multi-detector computed tomography
    Chee Khoon LIEW
    Rapaee ANNUAR
    Tiong Kiam ONG
    Sze Piaw CHIN
    Tobias Seyfarth
    Yean Yip FONG
    Choon Kiat ANG
    Houng Bang LIEW
    Kui Hian SIM
    Journal of Geriatric Cardiology, 2006, (01) : 2 - 8
  • [24] A prospective assessment of left atrial appendage thrombus with 320 detector row computed tomography in comparison with transesophageal echocardiography
    Kuronuma, K.
    Suzuki, Y.
    Sugai, S.
    Hayashida, S.
    Atsumi, W.
    Kawamorita, T.
    Sudo, M.
    Yagi, T.
    Komoriya, M.
    Yokoyama, K.
    Tachibana, E.
    Kunimoto, S.
    Matsumoto, N.
    Hirayama, A.
    EUROPEAN HEART JOURNAL, 2017, 38 : 888 - 889
  • [25] Comparison of cardiac measurements by multi-detector computed tomography angiography and transthoracic echocardiography in English bulldogs
    Hostnik, E. T.
    Scansen, B. A.
    Habing, A. M.
    Chiappone, G. A.
    Layman, R. R.
    White, R. D.
    JOURNAL OF VETERINARY CARDIOLOGY, 2017, 19 (06) : 480 - 491
  • [26] 320 Slice Computed Tomography Imaging-Based Semiquantitative Assessment of Left Ventricular Wall Motion: Comparison with Transthoracic Echocardiography
    Kataoka, Akihisa
    Funabashi, Nobusada
    Takaoka, Hiroyuki
    Uehara, Masae
    Takahashi, Akiyo
    Kobayashi, Yoshio
    CIRCULATION, 2011, 124 (21)
  • [27] Comparison of multi-detector row computed tomography with echocardiography for assessment of left ventricular function in healthy dogs
    Henjes, Christiane R.
    Hungerbuehler, Stephan
    Bojarski, Iwona B.
    Nolte, Ingo
    Wefstaedt, Patrick
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2012, 73 (03) : 393 - 403
  • [28] Left Atrial Volume and Function Assessment by Magnetic Resonance Imaging
    Hof, Irene E.
    Velthuis, Birgitta K.
    Van Driel, Vincent J.
    Wittkampf, Fred H.
    Hauer, Richard N.
    Loh, Peter
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2010, 21 (11) : 1247 - 1250
  • [29] Assessment of right ventricular function for patients with rheumatic mitral stenosis by 64-slice multi-detector row computed tomography: comparison with magnetic resonance imaging
    Zhang Xiao-chun
    Yang Zhi-gang
    Guo Yin-kun
    Zhang Rui-ming
    Wang Jian
    Zhou Dai-quan
    Cheng Lin
    Chen Lin
    CHINESE MEDICAL JOURNAL, 2012, 125 (08) : 1469 - 1474
  • [30] Assessment of coronary arteries in patients with atrial fibrillation by 320-detector computed tomography
    Imamura, T.
    Tanabe, K.
    Kishi, S.
    Taniwaki, M.
    Nakajima, H.
    Ibukuro, K.
    Aoki, J.
    Tanimoto, S.
    Otsuki, S.
    Hara, K.
    EUROPEAN HEART JOURNAL, 2010, 31 : 141 - 141