Understanding DC-side high-frequency resonance in MMC-HVDC system

被引:4
|
作者
Li, Chang [1 ]
Li, Yong [1 ]
Cao, Yijia [1 ]
Zhu, Hongqi [1 ]
Rehtanz, Christian [2 ]
Haeger, Ulf [2 ]
机构
[1] Hunan Univ, Coll Elect & Informat Engn, Changsha, Hunan, Peoples R China
[2] TU Dortmund Univ, Inst Energy Syst Energy Efficiency & Energy Econ, Dortmund, Germany
基金
中国国家自然科学基金;
关键词
voltage-source convertors; HVDC power convertors; HVDC power transmission; transfer functions; resonance; Nyquist diagrams; time-domain analysis; frequency response; power transmission control; DC-side high-frequency resonance; MMC-HVDC system; direct-current DC-side resonance; DC network; single input single output transfer function; modular multilevel converter-based high-voltage DC system; small signal model; Nyquist curve; power transfer capability; impedance model; time-domain simulations; power system computer-aided design-electromagnetic transient design; active damping control approach; resonance suppression; MODULAR MULTILEVEL CONVERTER; SIGNAL STABILITY ANALYSIS; CONSTANT POWER LOADS; VSC-HVDC; MICROGRIDS;
D O I
10.1049/iet-gtd.2017.1394
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Instability on direct-current (DC)-side resonance occurs if the connected converters interact with the DC network. In this study, a single-input-single-output transfer function is built to investigate the DC-side resonance of modular multilevel converter-based high-voltage DC (MMC-HVDC) system. The small signal model is developed for the DC-side resonance of an MMC-HVDC system. Furthermore, the system can be separated into two subsystems, i.e. H(s) and G(s). This study shows that both amplitudes of H(s), i.e. Abs [H(s)] and resonance peak of G(s) affect the encirclement radius of the Nyquist curve, and the encirclement radius reaches the largest at the resonance frequency. More importantly, the power transfer capability is restricted by the DC-side resonance since the more transmitted power leads to larger Abs [H(s)]. The impedance model is verified by both time-domain simulations and frequency responses imposed by impedance frequency scan in power systems computer-aided design/electro-magnetic transient design and control. Besides, an active damping control approach is introduced to suppress the resonance on DC side.
引用
收藏
页码:2247 / 2255
页数:9
相关论文
共 50 条
  • [21] Cable Surge Arrester Operation Due to Transient Overvoltages Under DC-Side Faults in the MMC-HVDC Link
    Ajaei, Firouz Badrkhani
    Iravani, Reza
    IEEE TRANSACTIONS ON POWER DELIVERY, 2016, 31 (03) : 1213 - 1222
  • [22] DC Side Harmonic Resonance Analysis of MMC-HVDC Considering Wind Farm Integration
    Ji, Ke
    Pang, Hui
    Yang, Jie
    Tang, Guangfu
    IEEE TRANSACTIONS ON POWER DELIVERY, 2021, 36 (01) : 254 - 266
  • [23] A Frequency Estimation-Based Adaptive Mitigation Approach for High-Frequency Oscillation in MMC-HVDC System
    Guo, Chunyi
    Du, Dongye
    Cheng, Hao
    Gan, Fanxin
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2024, 39 (04) : 5509 - 5521
  • [24] Research on the Fault Characteristics of DC side Based on MMC-HVDC
    Lu YanChun
    Liu TongLiang
    Jiang GangGang
    Zhang Yue
    Liu YanWei
    2018 CHINESE AUTOMATION CONGRESS (CAC), 2018, : 520 - 525
  • [25] High-Frequency Resonance Suppression Based on Cross-Coupled Filter and Improved Passive Damper for MMC-HVDC System
    Liu, Yiqi
    Liu, Jiayi
    Wang, Tianhao
    Zhang, Fei
    Zheng, Junyuan
    Yin, Laicheng
    Ban, Mingfei
    IEEE TRANSACTIONS ON POWER DELIVERY, 2024, 39 (03) : 1952 - 1962
  • [26] High-frequency oscillation analysis and suppression strategy of MMC-HVDC system based on generalized eigenvalue
    Zhang F.
    Yao W.
    Zhang Z.
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2022, 42 (08): : 174 - 183
  • [27] Analysis on High-frequency Oscillation Mechanism for MMC-HVDC System Considering Influence of Time Delay
    Guo C.
    Peng Y.
    Xu L.
    Yang S.
    Hu Y.
    Guo, Chunyi (chunyiguo@outlook.com), 1600, Automation of Electric Power Systems Press (44): : 119 - 126
  • [28] DC-Side Harmonic Currents Calculation and DC-Loop Resonance Analysis for an LCC-MMC Hybrid HVDC Transmission System
    Zhang, Zheren
    Xu, Zheng
    Xue, Yinglin
    Tang, Geng
    IEEE TRANSACTIONS ON POWER DELIVERY, 2015, 30 (02) : 642 - 651
  • [29] DC current oscillations reduction in MMC-HVDC system
    Hafeez, Kamran
    Van den Bossche, Alex
    JOURNAL OF POWER TECHNOLOGIES, 2024, 104 (01): : 86 - 97
  • [30] High-frequency Resonant Suppression by MMC-HVDC Converter Impedance Adaptive Remodeling
    Yang W.
    Wang X.
    Wang S.
    Li T.
    Lu Q.
    Dianwang Jishu/Power System Technology, 2022, 46 (11): : 4473 - 4481