Measurement of Tip Apex Distance and Migration of Lag Screws and Novel Blade Screw Used for the Fixation of Intertrochanteric Fractures

被引:3
|
作者
Yang, Jesse Chieh-Szu [1 ]
Chen, Hsin-Chang [2 ,3 ]
Lai, Yu-Shu [4 ,5 ]
Cheng, Cheng-Kung [2 ,6 ]
机构
[1] Taipei Vet Gen Hosp, Dept Orthopaed, Div Joint Reconstruct, Taipei, Taiwan
[2] Natl Yang Ming Univ, Dept Biomed Engn, Taipei, Taiwan
[3] Taipei City Hosp, Dept Orthopaed, Taipei, Taiwan
[4] Natl Yang Ming Univ, Orthopaed Device Res Ctr, Taipei, Taiwan
[5] Natl Yang Ming Univ, Orthopaed Device Res Ctr, Taipei, Taiwan
[6] Natl Yang Ming Univ, Dept Biomed Engn, Taipei, Taiwan
来源
PLOS ONE | 2017年 / 12卷 / 01期
关键词
DYNAMIC HIP SCREW; CEMENT AUGMENTATION; GAMMA-NAIL; CUTOUT; RESISTANCE; FAILURE; PLATE;
D O I
10.1371/journal.pone.0170048
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Fixation with a dynamic hip screw (DHS) is one of the most common methods for stabilizing intertrochanteric fractures, except for unstable and reverse oblique fracture types. However, failure is often observed in osteoporotic patients whereby the lag screw effectively 'cuts out' through the weak bone. Novel anti-migration blades have been developed to be used in combination with a lag screw ('Blade Screw') to improve the fixation strength in osteoporotic intertrochanteric fractures. An in-vitro biomechanical study and a retrospective clinical study were performed to evaluate lag screw migration when using the novel Blade Screw and a traditional threaded DHS. The biomechanical study showed both the Blade Screw and DHS displayed excessive migration (>= 10 mm) before reaching 20,000 loading cycles in mild osteoporotic bone, but overall migration of the Blade Screw was significantly less (p <= 0.03). Among the patients implanted with a Blade Screw in the clinical study, there was no significant variation in screw migration at 3-months follow-up (P = 0.12). However, the patient's implanted with a DHS did display significantly greater migration (P<0.001) than those implanted with the Blade Screw. In conclusion, the Blade Screw stabilizes the bone fragments during dynamic loading so as to provide significantly greater resistance to screw migration in patients with mild osteoporosis.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] A mathematical simulation of the tip-apex distance and the calcar-referenced tip-apex distance for intertrochanteric fractures reduced with lag screws
    Li, Shuang
    Chang, Shi-Min
    Jin, Yan-Min
    Zhang, Ying-Qi
    Niu, Wen-Xin
    Du, Shou-Chao
    Zhang, Li-Zhi
    Ma, Hui
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2016, 47 (06): : 1302 - 1308
  • [2] Value of Tip-Apex Distance (TAD) in the Fixation of Intertrochanteric Fractures by Dynamic Hip Screw (DHS)
    Khairy, Hossam Mohamed
    El-Alfy, Ali Tawfik
    El-Malt, Ahmed Elsayed
    Samy, Ramy Nabil
    ARCHIVES OF PHARMACY PRACTICE, 2019, 10 (03) : 81 - 86
  • [3] Intertrochanteric fracture fixation with Dynamic Hip Screw: Is tip-apex distance measurement useful for predicting fixation failure?
    Goh, K. L.
    Zamzuri, Z.
    Ariff, Mohd S.
    Azril, Mohamed M. A.
    INTERNATIONAL MEDICAL JOURNAL MALAYSIA, 2016, 15 (01) : 31 - 34
  • [4] Tip to apex distance in femoral intertrochanteric fractures: a systematic review
    Rubio-Avila, Jorge
    Madden, Kim
    Simunovic, Nicole
    Bhandari, Mohit
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2013, 18 (04) : 592 - 598
  • [5] Dynamic hip screw blade fixation for intertrochanteric hip fractures
    Leung, Frankie
    Gudushauri, Paata
    Yuen, Grace
    Lau, Tak-Wing
    Fang, Christian
    Chow, Shew-Ping
    JOURNAL OF ORTHOPAEDIC SURGERY, 2012, 20 (03): : 302 - 306
  • [6] Dynamic hip screw blade fixation for intertrochanteric hip fractures
    Dhamangaonkar, Anoop C.
    JOURNAL OF ORTHOPAEDIC SURGERY, 2013, 21 (01) : 132 - 133
  • [7] Impact of tip-apex distance and femoral head lag screw position on treatment outcomes of unstable intertrochanteric fractures using cephalomedullary nails
    Lee, Cheng-Hung
    Su, Kuo-Chih
    Chen, Kun-Hui
    Pan, Chien-Chou
    Wu, Yun-Che
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2018, 46 (06) : 2128 - 2140
  • [8] Audit of Tip-Apex Distance in Dynamic Hip Screw Fixation of Proximal Femoral Fractures
    Potter, M.
    Hickey, B.
    BRITISH JOURNAL OF SURGERY, 2024, 111
  • [9] Comparison of tip apex distance and cut-out complications between helical blades and lag screws in intertrochanteric fractures among the elderly: a meta-analysis
    Li, Shuang
    Chang, Shi-Min
    Niu, Wen-Xin
    Ma, Hui
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2015, 20 (06) : 1062 - 1069
  • [10] The prognostic value of tip-to-apex distance (TAD index) in intertrochanteric fractures fixed by dynamic hip screw
    Sedighi, Ali
    Sales, Jafar Ganjpour
    Alavi, Sahar
    ORTHOPEDIC REVIEWS, 2012, 4 (04) : 143 - 145