Value of Tip-Apex Distance (TAD) in the Fixation of Intertrochanteric Fractures by Dynamic Hip Screw (DHS)

被引:0
|
作者
Khairy, Hossam Mohamed [1 ]
El-Alfy, Ali Tawfik [1 ]
El-Malt, Ahmed Elsayed [1 ]
Samy, Ramy Nabil [1 ]
机构
[1] Zagazig Univ, Fac Med, Dept Orthoped Surg, Zagazig, Egypt
关键词
Value of Tip-Apex Distance (TAD); intertrochanteric fractures (ITF); cut-through; dynamic hip screw (DHS); FAILURE;
D O I
暂无
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Background: The fixation of ITF by DHS allows the compression of the fracture when the patients bear weight. Placement of lag screw should be central in the head and neck of the femur. This study aimed to emphasize the clinical value of the tip apex distance as a reliable predictor of the cut-out of the lag screw in the fixation of stable ITF. Patients & Methods: This was a retrospective cohort study that included 18 cases, skeletally mature patients with post-traumatic intertrochanteric fractures treated with DHS in the period from January 2016 to December 2016 with follow up of at least six months at Zagazig University Hospital. ITFs were internally fixated with DHS, and by postoperative follow-up, we measured the TAD post-operatively and after 6 months to detect the importance of TAD on the stability of lag screw in the head and neck of the femur and reported cases that developed cut-through of the lag screw. Results: TAD was the main measurement in the study. The rate of implant failure and cut-through was 27.8%. The median of TAD postoperative was 2.05. The median of TAD after 6 months was 2.23. There was a highly significant difference between the median of TAD after 6 months that developed cut-through and median of TAD after 6 months that did not develop cut-through (p-value <0.001). Conclusions: TAD of less than 25mm is safe and more than 25mm may result in the penetration of implant, non-union, cut-through, and other complications. Therefore, TAD is a reliable factor and has great value in DHS operations.
引用
收藏
页码:81 / 86
页数:6
相关论文
共 50 条
  • [1] SYSTEMATIC REVIEW OF TIP APEX DISTANCE (TAD) IN DYNAMIC HIP SCREW (DHS) FIXATION OF OSTEOPOROTIC HIP FRACTURES
    Abdulkareem, Imran Haruna
    OSTEOPOROSIS INTERNATIONAL, 2012, 23 : S606 - S607
  • [2] The prognostic value of tip-to-apex distance (TAD index) in intertrochanteric fractures fixed by dynamic hip screw
    Sedighi, Ali
    Sales, Jafar Ganjpour
    Alavi, Sahar
    ORTHOPEDIC REVIEWS, 2012, 4 (04) : 143 - 145
  • [3] Audit of Tip-Apex Distance in Dynamic Hip Screw Fixation of Proximal Femoral Fractures
    Potter, M.
    Hickey, B.
    BRITISH JOURNAL OF SURGERY, 2024, 111
  • [4] Intertrochanteric fracture fixation with Dynamic Hip Screw: Is tip-apex distance measurement useful for predicting fixation failure?
    Goh, K. L.
    Zamzuri, Z.
    Ariff, Mohd S.
    Azril, Mohamed M. A.
    INTERNATIONAL MEDICAL JOURNAL MALAYSIA, 2016, 15 (01) : 31 - 34
  • [5] THE VALUE OF THE TIP-APEX DISTANCE IN PREDICTING FAILURE OF FIXATION OF PERITROCHANTERIC FRACTURES OF THE HIP
    BAUMGAERTNER, MR
    CURTIN, SL
    LINDSKOG, DM
    KEGGI, JM
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77A (07): : 1058 - 1064
  • [6] Awareness of tip-apex distance reduces failure of fixation of trochanteric fractures of the hip
    Baumgaertner, MR
    Solberg, BD
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (06): : 969 - 971
  • [7] A Comparison of Tip-Apex Distance at Various Angles of Fixation Devices in Hip Fractures
    Ali, Mohammed
    Al-Dadah, Oday
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (02)
  • [8] A mathematical simulation of the tip-apex distance and the calcar-referenced tip-apex distance for intertrochanteric fractures reduced with lag screws
    Li, Shuang
    Chang, Shi-Min
    Jin, Yan-Min
    Zhang, Ying-Qi
    Niu, Wen-Xin
    Du, Shou-Chao
    Zhang, Li-Zhi
    Ma, Hui
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2016, 47 (06): : 1302 - 1308
  • [9] Use of the Tip-Apex Distance in predicting Dynamic Hip Screw Cut Out in Intertrochanteric Fracture of the Femur in Asian Population
    Chua, Y. P.
    Kwan, M. K.
    Ng, W. M.
    Saw, A.
    MALAYSIAN ORTHOPAEDIC JOURNAL, 2011, 5 (02) : 24 - 27
  • [10] To Study the Effectiveness and Safety of Dynamic Hip Screw (DHS) Fixation for Intertrochanteric Fractures
    Awan, Malik Mohammad Yasin
    Amjad, Mohammad
    Shah, Abdullah
    Ahmed, Ijaz
    Shad, Muhammad Nauman
    Fatima, Ajaz
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2019, 13 (02): : 342 - 345